west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "Wang Jun" 3 results
  • Comparison of central foveal thickness and subfoveal choroidal thickness in healthy pregnancy and pre-eclampsia

    Objective To compare the central foveal thickness (CFT) and subfoveal choroidal thickness (SFCT) in healthy pregnant women and patients with pre-eclampsia. Methods A prospective control study. Twenty normal subjects, 20 healthy pregnant women and 20 patients with pre-eclampsia were included. The difference of gestational weeks between healthy pregnant women and patients with pre-eclampsia was not significant (χ2=0.012, P=0.913). The differences of age and spherical equivalent among normal subjects, healthy pregnant women and patients with pre-eclampsia were not significant (χ2=1.760, 0.087; P=0.413, 0.957). All eyes underwent optical coherence tomography examination to measure the CFT and SFCT. Results The mean CFT of normal subjects, healthy pregnant women and patients with pre-eclampsia were (194.40±16.17), (201.2±17.33), (199.00±15.46) μm, there was no significant difference among the three groups (χ2=0.888, P=0.641). The mean SFCT of normal subjects, healthy pregnant women and patients with pre-eclampsia were (263.45±69.66), (330.00±49.20), (373.40±52.00) μm, there was significant difference among the three groups (χ2=22.818, P=0.000). The mean SFCT of healthy pregnant women was increased than that of normal subjects (Z=−2.991, P=0.002). The mean SFCT of patients with pre-eclampsia was increased than that of healthy pregnant women (Z=−2.638, P=0.007). Conclusion The mean SFCT of patients with pre-eclampsia is increased than healthy pregnant women.

    Release date:2017-11-20 02:25 Export PDF Favorites Scan
  • The effect of lens opacity on the measurement of retinal oxygen saturation

    Objective To analysis the effect of lens opacity on the measurement of retinal vessel oxygen saturation. Methods This was a cross sectional study. Forty four eyes of 44 patients with different degrees of lens opacity were enrolled. There were 23 males and 21 females. The patients aged from 48 to 84 years, with the mean age of (71.8±10.3) years. The mean best corrected visual acuity was 0.65±0.22. The mean intraocular pressure was (14.2±4.3) mmHg (1 mmHg=0.133 kPa). The mean equivalent spherical degree was (−0.05±2.10) D. The opitical quality analysis system was applied to measure intraocular objective scattering index (OSI) caused by lens opacity. According to the OSI, the opacity of lens was divided into four groups. Patients with OSI value <1.0 was grouped to level 1, which indicated that the lens were basically transparent; patients with OSI value between 1.0 and 3.0 was grouped to level 2, which indicated early cataract; patients with OSI value between 3.0 and 7.0 was grouped to level 3, which indicated progressive cataract; patients with OSI value >7.0 was grouped to level 4, which indicated the mature stage of cataract. The retinal oximeter Oxymap T1 was used to capture the fundus images under different wavelengths. Pearson correlation analysis was used to analyze the correlation between retinal oxygen saturation and age, intraocular pressure, equivalent spherical degree and OSI. One way ANOVA was used to analyze the difference of retinal oxygen saturation among groups. Results The mean retinal arterial oxygen saturation, venous oxygen saturation and arteriovenous difference was (90.70±6.46)%, (47.34±13.51)%, (43.36±10.09)%, respectively. The correlations of retinal arterial oxygen saturation, venous oxygen saturation and arteriovenous difference with age, intraocular pressure, equivalent spherical degree was not statistically significant (all P>0.05). The retinal arterial oxygen saturation and venous oxygen saturation was negatively correlated with OSI (r=−0.462,−0.500; P=0.002, 0.001), the arteriovenous difference and OSI was positively correlated (r=0.373, P=0.013). According to lens opacity, there were 11 eyes in level 1, 9 eyes in level 2, 14 eyes in level 3, 10 eyes in level 4. There were significant differences of retinal artery and venous oxygen saturation among different lens opacity levels (F=5.340, 4.710; P=0.003, 0.007); meanwhile, the arteriovenous difference was not significantly different (F=2.048, P=0.123). The retinal arterial oxygen saturation and venous oxygen saturation was significantly lower in the level 4 lens opacity group than any other three groups (all P<0.05), but there was no statistically significant difference among level 1 to level 3 lens opacity group. Conclusion The effect of lens opacity of level 1 to level 3 is limited on the measurement of retinal oxygen saturation, but level 4 lens opacity will cause decrease of retinal artery and venous oxygen saturation.

    Release date:2017-11-20 02:25 Export PDF Favorites Scan
  • The image characteristics of spectral-domain optical coherence tomography on retinal tuft

    Objective To describe the spectral-domain optical coherence tomography (SD-OCT) features of retinal tuft. MethodsA retrospective clinical study. From May 2019 to April 2020, 22 patients (22 eyes) diagnosed as retinal tuft by clinical fundus examination in Eye Hospital of Wenzhou Medical University at Hangzhou were included in the study. There were 9 eyes in 9 males and 13 eyes in 13 females. All patients underwent ultra-widefield laser scanning fundus photography and SD-OCT examination. SD-OCT was performed with a 55° wide-angle lens to observe the morphology, color, size and location of the lesions. ResultsTwenty-six retinal tuft lesions were found in 22 eyes, all of which were solitary, gray, thylakoid and protrusion. SD-OCT images showed that all the lesions of retinal tuft showed a local protuberant appearance with moderate and hyperreflectivity, which was higher than the surrounding retina plane. In 22 lesions (84.62%, 22/26), there were one or more irregular hyporeflective cavities between the retinal neuroepithelial layers, and the other 4 lesions (15.38%,4/26) contained no hyporeflective cavities. In addition, 23 cases (88.46%, 23/26) with hyperreflective condensed cortical vitreous attached to the retina at the top of lesions, 8 cases (30.77%, 8/26) with retinal tear, and 6 cases (23.08%, 6/26) with shallow retinal detachment. ConclusionsIn SD-OCT, the retinal tufts show moderate and strong local protrusion, which are higher than the surrounding retinal plane. In most of the lesions, there are multiple or single irregular weak reflex cavities, and there are hyperreflective condensed cortical vitreous attached to the retina at the top of lesions. Local retinal tears or shallow retinal detachment are present in some lesions.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content