west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "XIAOXijun" 2 results
  • Long-term Characteristics and Clinical Significance of Echocardiogram in Patients after Mechanical Prosthesis Aortic Valve Replacement

    The main purpose of this study is to observe and analyze the characteristics and the clinical significance of long-term echocardiogram data in patients after mechanical aortic valve replacement operation. Fifty-five cases were recruited over 5 years after mechanical aortic valve replacement operation, with complete echocardiogram examination profiles. The 55 subjects were divided into predominate aortic stenosis group and predominate aortic regurgitation group, based on preoperative examinations. And another way of division was also carried out that according to the effective orifice area index (EOAI), the subjects were divided into three groups, i.e., severe prosthesis-patient mismatch (PPM) group, moderate PPM group, and non PPM group. Characteristics of long-term echocardiogram data of the subjects were analyzed. Patients with aortic stenosis showed significantly decreased thickness of intraventricular septum and left ventricular posterior wall about half a year after operation (P<0.05). Half a year after operation, patients with aortic regurgitation showed decreased left ventricular internal dimension diastole and left ventricular internal dimension systole, and increased ejection fraction (P<0.05). Differences in mean aortic valve pressure gradient, forward blood flow across the aortic valves, and ejection fraction were not significant among those with severe PPM, moderate PPM, and non PPM groups (P>0.05). Number of cases of ascending aorta dimension increased as time goes on and pathogenesis of other valve diseases. A conclusion could be drawn that the heart function of patients with aortic valve disease could be improved after mechanical aortic valve replacement operation, but pathologies in other valves and ascending aorta might be increased, and therefore periodical postoperative echocardiogram evaluation with long tem pharmaceutical therapy could be necessary.

    Release date: Export PDF Favorites Scan
  • Early evaluation of quality of anticoagulant therapy in patients with mechanical prosthetic valve replacement through TTR and FTTR

    Objective To evaluate the quality of anticoagulant therapy in patients with mechanical prosthetic valve replacement during early period through time in therapeutic range(TTR) and fraction of time in therapeutic range(FTTR), and to provide an objective evidence for further improving quality of anticoagulant therapy. Methods All the patients were followed and registered in hospital and at outpatient clinic from July 2012 through April 2014, with a maximum of 6 months after surgery. Targeted international normalized rate (INR) was 1.60 to 2.20, acceptable INR was 1.50 to 2.30. And warfarin weekly dosage adjustment was used as the strategy of anticoagulation management. Adjusting the warfarin dosage when INR was beyond acceptable INR. Events of bleeding, thrombogenesis and thromboembolism, TTR and FTTR of these patients during the follow-up were collected to evaluate quality of anticoagulant therapy in these patients. Results A total 477 patients and 2 755 reports of INR values were included for data analysis. The follow-up time was 78 918 days. Values of INR varied from 0.92 to 7.72(1.83±0.64). Required weekly doses of warfarin in target INR and acceptable INR were 5.00–35.00(18.15±3.99) mg/week and 5.00–39.38(18.29±4.08) mg/week. TTR of target INR and acceptable INR was 36.85%(27 079.5 d/78 918.0 d) and 49.84% (39 331.5 d/78 918.0 d), respectively. FTTR of target INR and acceptable INR was 37.31% (1 028 times/2 755 times), 50.01% (1 378 times/2 755 times), respectively. TTR of target INR and acceptable INR was 46.04%(3 902.5 d/8 475.5 d), 59.49%(5 042 d/8 475.5 d) when the patients’ follow-up was up to six months and FTTR of target INR and acceptable INR value of these patients was 46.81%(206 times/440 times), 60.45%(266 times/440 times). During the follow-up, there were 3 thromboembolism events, 1 transient physical abnormal activity, and 1 thrombogenesis in the left atrium, and there was no bleeding and death events. Conclusion The strategy of anticoagulation management used in our study is reasonable. In order to further improve the patients’ quality of anticoagulant therapy, it is necessary to start anticoagulation after operation as soon as possible, to strengthen the education of patients with anticoagulant knowledge and to increase INR test frequency properly.

    Release date:2017-01-22 10:15 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content