west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "Xiao Yuanyuan" 2 results
  • Characteristics of optical coherence tomography in patients with primary vitreoretinal lymphoma

    ObjectiveTo observe the image characteristics of optical coherence tomography (OCT) in patients with primary vitreoretinal lymphoma (PVRL).MethodsA retrospective clinical study. Thirty-two eyes of 19 patients diagnosed with PVRL by vitreous pathology in the Department of Ophthalmology, Beijing Tongren Hospital from September 2016 to October 2019 were included in this study. There were 7 males and 12 females. The median age was 56 years. The mean time from symptom onset to final diagnosis was 6.1±3.8 months. The first diagnosis was uveitis in 12 cases (63.1%, 12/19), retinal vein occlusion in 2 cases (10.5%, 2/19), central retinal artery occlusion in 1 case (5.3%, 1/19), and suspected PVRL of camouflage syndrome in 4 cases (21.1%, 4/19). Routine ophthalmic examination and frequency-domain OCT examination were performed in all the patients, and typical images were stored for analysis. According to the examination results, PVRL OCT signs were divided into vitreous cells, inner retinal infiltration, outer retinal infiltration, retinal pigment epithelial (RPE) infiltration, sub-RPE infiltration, and subretinal fluid.ResultsVitreous cells were found in all eyes (100.0%, 32/32). RPE infiltrated were observed in 19 eyes (59.4%, 19/32), RPE infiltration in 16 eyes (50.0%, 16/32), outer retinal infiltration in 8 eyes (25.0%, 8/32), inner retinal infiltration in 16 eyes (50.0%, 16/32), and subretinal fluid in 4 eyes (12.5%, 4/32).ConclusionsPVRL OCT signs can involve vitreous and retinal anatomical levels, including vitreous cells, inner retinal infiltration, outer retinal infiltration, RPE infiltration, sub-RPE infiltration and subretinal fluid. The same patient can show multiple signs at the same time.

    Release date:2021-03-19 07:10 Export PDF Favorites Scan
  • Compared non-mydriatic two-field 45° fundus imaging methods with non-mydriatic two ultra-widefield fundus imaging in a large-scale diabetic retinopathy screening

    ObjectiveTo compare the consistency and difference of non-mydriatic two-field 45° ultra-wide field Optos and Clarus500 fundus imaging in a large-scale diabetic retinopathy (DR) screening. MethodsA diagnostic methodology study. From November 2020 to August 2021, 526 eyes of 277 patients with type 2 diabetes who diagnosed in Department of Ophthalmology, Henan Provincial People's Hospital were included in the study. Among them, there were 175 males with 328 eyes and 102 females with 198 eyes; the age was 53±10 years old. The same experienced technician performed the non-mydriatic dual-field 45° fundus imaging and the non-mydriatic ultra-wide-angle imaging system Optos, Clarus500 single-field fundus imaging examination on the patient on the same day, and obtained the dual-field 45° fundus image and Optos, Clarus500 single-field fundus image. The Optos and Clarus500 single-field fundus images in the same area as the dual-field 45° fundus image were captured by Photoshop software, and the Optos and Clarus500 dual-field fundus images were obtained. Subsequently, two experienced ophthalmologists performed interpretation and DR grading of the 5 groups of images, respectively. Images with inconsistent grading results were interpreted by a third ophthalmologist and used as the final grading result. In order to avoid the mydriatic dual-field 45° imaging interpretation results as the standard, the consistency and detection rate difference of the two ultra-wide-angle imaging systems in the rapid DR screening results were evaluated. The weighted Kappa (κ) test was used to analyze the consistency of DR diagnosis between dual-field 45° fundus imaging and Optos and Clarus500 fundus imaging; χ2 test was used to compare the detection rates of DR between different imaging systems. ResultsCompared with the dual-field 45° fundus image, the Clarus500 single-field had a higher DR detection rate (χ2=24.965, P<0.001), and the Optos dual-field fundus image had a lower DR detection rate (χ2=49.559, P<0.001). Compared with the DR detection rate of dual-field 45° fundus image, Optos single-field fundus image, Clarus500 double-field fundus image had no significant difference (χ2=2.572, 0.649; P=0.109, 0.421). Compared with Optos, Clarus500 single-field and dual-field fundus images DR detection rate, the difference was statistically significant (χ2=43.214, 61.216; P<0.001). Consistency assessment of DR grading results: dual-field 45° fundus images and Clarus500 dual-field fundus images (κ value=0.932, 95% confidence interval (CI) 0.907-0.956) were highly consistent; dual-field 45° fundus images and Optos single-field fundus images [κ value=0.474, 95%CI 0.417-0.532], Optos dual-field fundus image (κ value=0.495, 95%CI 0.438-0.551), Optos dual-field fundus image (κ value=0.495, 95%CI 0.438-0.551) and Clarus500 dual-field fundus image (κ value=0.452, 95%CI 0.395-0.506) were moderately consistent; dual-field 45°fundus images and Clarus500 single-field fundus images (κ value=0.354, 95%CI 0.303-0.403) and Optos single-field fundus images and Clarus500 single-field fundus images (κ value=0.347, 95%CI 0.287-0.393) showed general agreement. ConclusionsCompared with Optos dual-field fundus image, dual-field 45°fundus image and Clarus500 dual-field fundus image have high consistency in the grading results of DR rapid screening. Compared with Optos single-field fundus image, the detection rate of the DR of Clarus500 single-field fundus image is higher.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content