Objective The use of autologous platelet-rich gel (APG) is a relatively new technology and a promising treatment method for infections, which is currently being used by a variety of surgical specialties. The mechanism of antibacterialeffect of APG is not yet fully discovered. Subsequent evidence suggests that platelets have multi ple functional attributes inantimicrobial host defense (including the capacity to generate antimicrobial oxygen metabol ites and the antimicrobial peptides) and interact directly with microorganisms, contribute to clearance of pathogens from the blood. To investigate the bacteriostasis of APG against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa in vitro. Methods Platelet-rich plasma (PRP) and platelet-poor plasma (PPP) were obtained from whole blood of 17 healthy donors. APG was prepared by mixing PRP with bovine thrombin in a 10% calcium gluconate solution or bovine thrombin in a 10% calcium gluconate solution and apocynin (APG-APO). Antibacterial effects of APG, PRP, and APG-APO on Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were evaluated by bacteriostasis assay. Results The culture results showed apparent decrease in the number of Staphylococcus aureus for both APG and APG-APO, which was maximal at first 4 hours and lasted to 24 hours and 8 hours, respectively; showing significant difference (P lt; 0.05) when compared APG with PRP and PPP, however no significant difference at first 8 hours (P gt; 0.05) and significant difference at 12 and 24 hours (P lt; 0.05) when compared APG with APG-APO; showing significant difference at first 4 hours (P lt; 0.05), no significant difference at 6, 8, 12, and 24 hours when compared APG-APO with PRP and PPP (P gt; 0.05). The bacteriostasis rates of APG and APG-APO were 27.36%-52.97% and 18.82%-51.52% against Escherichia coli, respectively; showing no significant difference (P gt; 0.05) when compared with PRP. The bacteriostasis rates of APG and APG-APO were less than 35% against Pseudomonas aeruginosa, showing no significant difference (P gt; 0.05) when compared with PRP; the bacteriostasis rates of PRP were less than 15% against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. Conclusion APG may have potential bacteriostatic effect against Staphylococcus aureus by platelet mediating. Either APG or APG-APO has no obvious bacteriostatic effect against Escherichia coli or Pseudomonas aeruginosa. PRP has no antibacterial activity against Staphylococcus aureus, Escherichia coli or Pseudomonas aeruginosa.
Objective To review the mechanism of cold atmospheric plasma (CAP) in the treatment of chronic skin ulcer, providing a new idea for ulcer therapy. Methods The literature about CAP in the treatment of chronic skin ulcers in recent years was extensively screened and reviewed. The treatment principle, active ingredients, and mechanism were summarized. Results CAP is partial ionized gas discharged by plasma generator in high frequency under high voltage. It contains electrons, positive and negative ions, reactive oxygen species, reactive nitrogen species, and ultraviolet rays. In vitro and animal experiments show that the active ingredients contained in CAP can inactive microorganisms, against biofilm, regulate immune-mediated inflammatory, promoting blood flow, stimulate tissue regeneration and epithelial formation in the course of wounds healing. Conclusion CAP play a role in different stages of chronic skin ulcer healing, with good effectiveness and safety, and broad clinical application prospects. But more studies are needed to explore the indications and dosages of CAP therapy.
Objective To investigate the satisfaction of participants in Wenjiang District of Chengdu regarding the New-style Rural Cooperative Medical Care (NRCMC), and to analyse its factors in order to help the decision makers optimize and improve the scheme in the future.Methods Three towns of Wenjiang District were selected for study by computer simple random sampling. Five percent of NRCMC participants were randomly selected in Wenjiang for a face-to-face interview using a questionnaire. Data entry and statistical analysis were completed by Epidata 3.0 and SPSS 11.5 respectively. Results A total of 2500 questionnaires were conducted for face-to-face interviews, and 2438 questionnaires were returned (response rate 97.6%); 58% participants were satisfied with NRCMC, and the results of stepwise multiple logistic regression analysis indicated that their desire to participation (partial regression coefficient B=-3.54, P=0.014) and the satisfaction with the present compensation proportion (partial regression coefficient B=-4.62, P=0.018) were the most important factors that influenced the total satisfaction with NRCMC.Conclusion It is of great significance to strengthen the promotion of NRCMC; reasonably establish the compensation mode and proportion; encourge voluntary participation for the sake of their benefits to improve the quality and performance of NRCMC.
Objective To evaluate the accuracy of newer-generation home blood glucose meter (Accu-Check? Integra) in patients with impaired glucose regulation (IGR) and newly-diagnosed type 2 diabetes mellitus. Methods A cross-sectional study was performed on 109 cases with newly-diagnosed type 2 diabetes or IGR who were asked to take oral glucose tolerance test (OGTT), while paired samples, that were Accu-Check? Integra in capillary blood glucose (CBG) and laboratory glucose in venous plasma glucose (VPG ), were taken simultaneously. Taking VPG as the reference value, the accuracy of the home glucose meter was assessed according to the international standardization organization (ISO), including, the accuracy was studied by means of Median absolute difference (Median AD) and Median absolute relative difference (Median RAD), the consistency of CBG and VPG was studied by Clarke Error Grid analysis, the correlation of CBG and VPG was analyzed according to liner regression analysis, and the sensitivity and specificity for hyperglycemia were also calculated. Results There were 292 VPG values paired with CBG values, among which 93.49% of CBG values met ISO home glucose meter criteria, the median AD was 7.2 mg/dL, and the median RAD was 4.76%. Paired glucose measurements from the Accu-Check Integra meter and laboratory glucose measurement demonstrated that 100% of paired points in the overall subject population fell in zones A and B of the Clarke Error Grid. The CBG value was well correlated to VPG value in the overall level, and the sensitivity and specificity were 94.6% and 95.7% respectively for hyperglycemia. Conclusion The newer-generation home blood glucose meter (Accu-Check? Integra) demonstrates a high degree of accuracy, and it can precisely report the real value of blood glucose.