west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "YAOLan-hui" 3 results
  • Value of Contrast-enhanced Ultrasound in Diagnosis of Benign and Malignant Renal Tumors: A Meta-Analysis

    ObjectiveTo systematically review the value of contrast-enhanced ultrasound in diagnosis of benign and malignant renal tumors. MethodsSuch databases as PubMed, EMbase, The Cochrane Library (Issue 9, 2013), CBM, CNKI, WanFang Data and VIP were searched by Sep 31st, 2013. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data, and assessed the methodological quality of included studies. Then meta-analysis was performed using Meta-Disc 1.4 software. ResultsSeven studies involving 462 patients were finally included. ROC curve showed shoulder-arm shape. The results of Spearman suggested significance of the threshold effect. The results of meta-analysis showed that, the area under curve (AUC) was 0.98. ConclusionContrast-enhanced ultrasound can improve diagnostic accuracy, which is of important value in the diagnosis and differential diagnosis of benign and malignant renal tumors. Due to limited quality and quantity of the included studies, the abovementioned conclusion still needs to be verified by conducting more high quality studies.

    Release date: Export PDF Favorites Scan
  • Value of Intra-operative Ultrasound in Diagnosis of Tumor Residue after Resection of Intracranial Gliomas: A Meta-Analysis

    ObjectiveTo systematically review the value of intra-operative ultrasound in diagnosis of tumor residue after resection of intracranial gliomas. MethodsSuch databases as PubMed, EMbase, The Cochrane Library, CBM, CNKI, WanFang Data and VIP were electronically searched for the diagnostic test about intra-operative ultrasound in diagnosis of tumor residue after resection of intracranial gliomas by March 31st, 2013. Meanwhile, search engines such as Google, Baidu were also used for relevant search. According to the inclusion and exclusion criteria, the literature was screened and the data were extracted. The methodological quality was evaluated in accordance with the quality assessment tool for diagnostic accuracy studies (QUADAS) and then meta-analysis was conducted using Meta-DiSc 1.4 software. ResultsA total of 10 studies involving 423 patients were included. The results of meta-analysis showed that the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio (DOR) were 0.78 (95%CI 0.74 to 0.82), 0.90 (95%CI 0.88 to 0.90), 5.12 (95%CI 2.86 to 9.16), 0.29 (95%CI 0.21 to 0.39) and 25.00 95%CI (13.27 to 47.10), respectively; and the AUC was 0.89. In the subgroup analysis, for low grade intracranial gliomas, the results of meta-analysis showed that the sensitivity, specificity and DOR were 0.87 (95%CI 0.77 to 0.94), 0.88 (95%CI 0.78 to 0.94) and 28.93 (95%CI 7.46 to 112.14), respectively, and the AUC was 0.92. For high grade gliomas, the results of meta-analysis showed that the sensitivity, specificity and DOR were 0.80 (95%CI 0.72 to 0.87), 0.67 (95%CI 0.53 to 0.79) and 7.20 (95%CI 3.04 to 17.09), respectively, and the AUC was 0.80. ConclusionIntra-operative ultrasound is useful for the diagnosis of tumor residue after resection of intracranial gliomas, especially for low grade gliomas.

    Release date: Export PDF Favorites Scan
  • Value of Ultrasound Contrast Agents Injected Subcutaneously for Diagnosing Sentinel Lymph Nodes of Breast Cancer: A Meta-analysis

    ObjectiveTo systematically review the value of ultrasound contrast agents injected subcutaneously for diagnosing sentinel lymph nodes of breast cancer. MethodsWe electronically searched databases including PubMed, EMbase, The Cochrane Library, CNKI, CBM, WanFang Data, and Medalink from their inception to July 2014, to collect diagnostic accuracy studies of ultrasound contrast agents injected subcutaneously for diagnosing sentinel lymph nodes of breast cancer. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using Meta-Disc 1.4 software. ResultsEight studies involving 311 sentinel lymph nodes were included. The results of meta-analysis showed that, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and the area under curve (AUC) of SROC were 0.89 (95%CI 0.84 to 0.93), 0.81 (95%CI 0.72 to 0.87), 4.14 (95%CI 2.20 to 7.79), 0.15 (95%CI 0.10 to 0.25), 33.23 (95%CI 11.17 to 98.83), and 0.96 respectively. ConclusionContrast-enhanced ultrasound has a high value in diagnosis of sentinel lymph nodes of breast cancer. Due to limited quality and quantity of the included studies, more high quality and large-scale studies are needed to verify the above conclusion.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content