west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "YU Qinmei" 2 results
  • ORTHOGONAL ANALYSIS OF PHYSICAL PARAMETERS OPTIMIZATION OF MICROBUBBLE-ENHANCED SONO-THROMBOLYSIS

    ObjectiveTo investigate the main influence factors of microbubble-enhanced sono-thrombolysis by an orthogonal array experimental design (OAD) and to confirm the optimal parameters of microbubble-enhanced sono-thrombolysis in vitro. Methods The peripheral blood was collected from 50 female Sprague Dawley rats to prepare the standard plasma, and then 100 μL standard plasma and 25 μL thrombin (0.15 U/μL) were mixed and incubated in 37℃ water bath for 3, 6, 12, and 24 hours respectively to prepare corresponding standardized thrombus. The physical parameters for the designed experiments included transmit powers of ultrasound (factor A: 5%, 25%, 50%, and 100%), microbubble volume (factor B: 50, 100, 200, and 400 μL), urokinase (UK) concentration (factor C: 100, 200, 400, and 800 U/mL), and thrombolysis time (factor D: 10, 20, 30, and 40 minutes), respectively. Then an OAD based on four parameters and four levels [L16(45)] was employed to optimize the thrombolysis conditions. The ultrasound frequency was 1.82 MHz. HE staining and scanning electron microscope (SEM) were used to observe the clots before and after thrombolysis. The thrombolysis rate was measured. ResultsHE staining and SEM observation showed that the fibrin was dissolved after thrombolysis. According to the OAD, the optimal parameter combination was C4-D4-A1-B4, indicating UK concentration 800 U/mL, thrombolysis time 40 minutes, transmit power of ultrasound 5%, and microbubble volume 400 μL, respectively. The four factors above had significant influence on thrombolysis (P lt; 0.05), and UK concentration was the most significant. There were significant differences in thrombolysis between different thrombolysis time (P lt; 0.05). ConclusionUnder the condition of fixed ultrasound frequency, microbubble-enhanced sono-thrombolysis efficiency is better in lower transmit power of ultrasound, higher UK concentration, longer thrombolysis time, higher microbubble volume, and shorter thrombolysis time

    Release date:2016-08-31 05:39 Export PDF Favorites Scan
  • Clinical Research on the Improvement of Autologous Stem Cells Collection in Patients with Multiple Myeloma after Velcade-based Chemotherapy

    【摘要】 目的 研究以万珂为主化学疗法方案提高多发性骨髓瘤初发患者自体外周血造血干细胞采集的作用。 方法 回顾性分析2006年1月-2010年11月4例初发多发性骨髓瘤患者在万珂治疗后自体外周血造血干细胞采集的临床资料。疗效判定依据国际骨髓瘤工作组2006年疗效判断标准。 结果 经过万珂为主化学疗法方案治疗3~6个疗程(平均4个疗程)后,3例获得CR及以上疗效,均顺利实施了外周血造血干细胞采集;3例采集次数仅1次,1例为2次;平均获得CD34+细胞8.43×106/kg,完全达到采集要求。 结论 万珂为主化学疗法方案起效快、疗效好,可以提高初发多发性骨髓瘤患者的干细胞采集率。【Abstract】 Objective To explore the improvement of autologous stem cells collection in patients with newly-diagnosed multiple myeloma after Velcade-based chemotherapy.  Methods The clinical data of four patients with multiple myeloma who underwent Velcade-based chemotherapy between January 2006 and November 2010 were retrospectively analyzed. The therapeutic effect was observed. Results After 3-6 courses (mean 4 courses) of Velcade-based chemotherapy, 3 patients obtained complete remission (CR) and above response, and the sufficient peripheral blood hematopoietic stem cells were collected successfully. The peripheral blood hematopoietic stem cells were collected once in three patients and twice in one patient. Sufficient number of hematopoietic stem cells (mean CD34 positive-cell 8.43×106/kg) were collected which fully met the collection requirements. Conclusion Velcade-based chemotherapy has advantages of fast action and good therapeutic effect, which can improve the collection of autologous stem cells in patients with newly-diagnosed multiple myeloma.

    Release date:2016-09-08 09:25 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content