ObjectiveTo evaluates the values of fractional exhaled nitric oxide (FENO) in the treatment of chronic cough prospectively.MethodsSubjects with chronic cough were recruited from the outpatient clinic of China-Japan Friendship Hospital. All the patients accepted FENO tests, sputum cell counts, pulmonary function tests, bronchial provocation tests, serum IgE, cough symptom scores and Leicester Cough Questionnaire before and after treatment of 4 weeks.ResultsThere were 29 patients with cough variant asthma (CVA), 19 patients with eosinophilic bronchitis (EB) and 39 patients with other causes. The baseline FENO level of the subjects whose coughs were relieved after inhaled corticosteroids (ICS) therapy of 4 weeks was (63±42) ppb, significantly higher than those with bad-response [(28±13) ppb, P<0.01]. The proportion of FENO decrease after ICS therapy was not only significantly related to the proportion of eosinophilic decrease (r=0.54, P<0.01), but also significantly related to the proportion of decrease of cough symptom scores (r=0.48, P<0.01). To distinguish the good responders from bad responders, the optimal baseline FENO cutoff value was 36 ppb, with sensitivity of 82%, specificity of 93%, positive predictive value of 94%, negative predictive value of 87%, accuracy of 83%.ConclusionsThere is a good relationship between the FENO decreasing levels after ICS therapy and the reliefs of cough symptoms in the CVA and EB patients. Chronic cough patients with FENO value more than 36 ppb are indicated to respond to ICS therapy.
ObjectiveTo explore the clinical characteristics of idiopathic hypereosinophilic syndrome (IHES), and improve the early diagnosis and treatment of such diseases.MethodsThe clinical diagnosis and treatment data were retrospectively analyzed from the patients with confirmed IHES hospitalized in China-Japan Friendship Hospital between September 2010 to May 2018.ResultsFifteen patients were included. There were 3 women and 12 men in the study, with an average age of 53.7±21.3 years. Eleven patients had respiratory problems, with an average course of 7 months. Most lesions occurred in both lungs. Patchy distribution, ground glass opacity, pleural effusion and mediastinal lymph node enlargement were common in the chest computed tomography. Serum total IgE was significantly increased. Four patients had other systems involved rather than respiratory system. One of them had digestive problems and another 3 had skin diseases. There was a significant increase in eosinophils in peripheral blood, bone marrow and histopathology, the same as eosinophils in sputum, pleural effusion, and bronchoalveolar lavage fluid. Hypoxemia was common in patients with respiratory problems. The blood eosinophil and total IgE were reduced after glucocorticoid treatment, and the hypoxemia was significantly improved.ConclusionsThe clinical symptoms, signs and image of chest computed tomography are not specific in IHES, so the rate of misdiagnosis and wrong diagnosis is high. This disease involves many organs or systems, so the pathological examination should be completed as soon as possible to make a clear diagnosis to prevent further damage. Glucocorticoid treatment is effective in this disease.