west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHAO Guangzhi" 4 results
  • Clinical results of ultrasound-guided thoracoscopic atrial septal defect closure

    Objective To analyze the safety and effectiveness of ultrasound-guided thoracoscopic atrial septal defect (ASD) closure. Methods We prospectively collected the clinical data of 12 patients with ASD treated by ultrasound-guided thoracoscopic ASD closure in Fuwai Hospital from January to September 2017. The characteristics of the patients' ASD and operation, operation safety and effectiveness, postoperative complications and follow-up results were analyzed. Results Among the 12 patients, 10 were successfully treated with ultrasound-guided thoracoscopic ASD closure. Two patients switched to ASD repair under thoracoscopy-assisted cardiopulmonary bypass. The size of the ASD was 17-40 (27.22±8.97) mm and the size of the occluder was 36 (30-42) mm. The average postoperative length of hospital stay was 6 days. There were no complications such as arrhythmia, bleeding and pericardial effusion after operation. The average follow-up was 6 (3-10) months after the operation. During the follow-up, no Ⅲ-degree conduction block, occluder dislocation, residual shunt or cardiac pericardial effusion was found. Conclusion Ultrasound-guided thoracoscopic ASD closure is a minimally invasive, safe and effective treatment. This technique provides a new minimally invasive surgical option for patients with large defect diameter and poor edge condition.

    Release date:2018-06-01 07:11 Export PDF Favorites Scan
  • Midterm outcome of percutaneous balloon aortic valvuloplasty guided by single echocardiography for congenital aortic stenosis

    Objective To analyze the midterm outcome of patients with congenital aortic stenosis undergoing percutaneous balloon aortic valvuloplasty (PBAV) by single echocardiographic guidance. Methods The clinical data of 12 patients with congenital aortic stenosis who underwent PBAV by single echocardiographic guidance at Fuwai Hospital from January 2016 to November 2017 were retrospectively analyzed. There were 7 males and 5 females with an average age of 18.27±15.30 years. The preoperative peak pressure gradient was 61.8–110.0 (80.30±24.50) mm Hg, and 50% of patients had aortic regurgitation. Results All patients successfully underwent PBAV. Aortic annulus diameter was 18.65±3.17 mm and balloon diameter was 17.62±3.77 mm, with balloon diameter to annulus diameter ratio of 0.92±0.07. The peak transaortic gradient was 16-51 (36.72±12.33) mm Hg immediately after procedure, which was significantly different from the preoperation (P=0.000). During the follow-up period, the peak transaortic gradient was 21-58 (37.06±13.52) mm Hg, and there was no significant difference between the follow-up and immediate postoperation (P=0.310). Immediately after procedure and during follow-up, 58% of patients had aortic regurgitation, which was not statistically different from the preoperation (P=0.682). Conclusion Systematic use of Doppler echocardiographic guidance for PBAV is feasible, and that it is associated with a high success rate and a very low complication rate.

    Release date:2018-09-25 04:15 Export PDF Favorites Scan
  • Clinical investigation of percutaneous closure of patent ductus arteriosus under echocardiography guidance

    Objective To assess the efficacy and safety of percutaneous closure of patent ductus arteriosus (PDA) solely under echocardiography guidance. Methods We retrospectively analyzed the clinical data of 200 patients who received the percutaneous closure of PDA under echocardiography guidance in Fuwai Hospital from August 2013 to April 2016. According the different approach, they were divided into 2 groups: a femoral artery approach group (n=143) and a femoral vein approach group (n=57). In the femoral artery approach group, there were 42 males and 101 females aged 3.20±5.63 years. In the femoral vein group, there were 10 males and 47 females aged 7.30±11.36 years. All Patients were treated by percutaneous PDA closure solely under echocardiography guidance. The follow-up was performed at one month after the operation by echocardiography, chest radiograph and electrocardiogram. Results All 200 patients were successfully treated with percutaneous closure of PDA. The patients’ gender, in-hospital stay, rates of occluder detachment were similar between the two groups (P>0.05). Compared with the femoral vein approach group, the femoral artery approach group had a younger age (3.20±5.63 yearsvs. 7.30±11.36 years, P<0.001), less body weight (14.25±11.54 kgvs. 24.25±19.14 kg, P<0.001) and shorter diameter of PDA (3.06±0.79 mmvs. 5.93±0.68 mm, P<0.001) and PDA occluders (5.43±1.00 mmvs. 12.14±0.54 mm, P<0.001), but had higher hospitalization expenses (32 108.2±3 100.2 yuanvs.25 120.7±3 534.1 yuan, P<0.001). In the femoral vein approach group, one patient was closed under radiation guidance because guide wires could not pass through PDA. One patient in the femoral artery approach group suffered from occluder detachment at one day after operation and was cured by transthoracic minimally invasive PDA occlusion. There were no complications of occluder detachment, residual shunt, pericardial effusion or left pulmonary stenosis during the follow-up. Conclusion Echocardiography-guided percutaneous PDA closure is safe and effective, while the proper interventional approach should be chosen by the anatomical features of PDA.

    Release date:2018-06-26 05:41 Export PDF Favorites Scan
  • Transcatheter closure of atrial septal defect using fully biodegradable occluder under ultrasound guidance: A case report

    Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occlude under ultrasound guidance, achieving excellent results by interventional therapy.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content