west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHAO Zeyu" 8 results
  • Application and challenge of metagenomic next-generation sequencing in the diagnosis of pulmonary infection

    The morbidity and mortality of pulmonary infection are high among infectious diseases worldwide. Rapid and accurate etiological diagnosis is the key to timely and effective treatment. Metagenomic next-generation sequencing (mNGS) technology has brokenthrough the limitations of traditional pathogenic microorganism detection methods and improved the detection rate of pathogens. In this paper, the application and advantages of mNGS technology in the diagnosis of bacteria, fungi, viruses and mixed infections in the lungs are analyzed, and the challenges and breakthroughs in RNA detection, wall breaking of firmicutes and host DNA clearance are described, in order to achieve targeted and accurate etiological diagnosis through mNGS, so as to effectively treat pulmonary infections.

    Release date: Export PDF Favorites Scan
  • Application of simple Ilizarov ring external fixation technique in treatment of tibial plateau fracture complicated with osteofascial compartment syndrome

    ObjectiveTo explore the effectiveness of simple Ilizarov ring external fixation technique in treatment of tibial plateau fractures complicated with osteofascial compartment syndrome.MethodsBetween September 2013 and March 2017, 30 patients with tibial plateau fractures complicated with osteofascial compartment syndrome were treated with simple Ilizarov ring external fixation technique. There were 23 males and 7 females, with an average age of 34.4 years (range, 23-43 years). The injuries were caused by traffic accident in 12 cases, by falling from height in 4 cases, by falling in 8 cases, and by a crashing object in 6 cases. The time from injury to admission was 1-12 hours (mean, 4.8 hours). According to the Schatzker classification, there was 1 case of type Ⅱ, 3 cases of type Ⅲ, 10 cases of type Ⅳ, 7 cases of type Ⅴ, and 9 cases of type Ⅵ. All patients underwent fasciotomy due to osteofascial compartment syndrome; the interval between fasciotomy and operation was 10-15 days (mean, 12.5 days). Knee Society Score (KSS) and Ilizarov Method Research and Application Association (ASAMI) protocol were used to evaluate knee function.ResultsThe operation time was 110-155 minutes (mean, 123.1 minutes); the intraoperative blood loss was 100-500 mL (mean, 245 mL); the postoperative hospital stay was 3-5 days (mean, 3.8 days). All patients were followed up 20-24 weeks (mean, 22.7 weeks). Except for 2 patients with signs of needle tract infection, no other complication occurred. X-ray films showed that the fractures healed, and the healing time was 10-20 weeks (mean, 14.6 weeks). At last follow-up, the KSS clinical score was 70- 95 with an average of 87.5; the functional score was 70-90 with an average of 79.0. According to ASAMI protocol evaluation, the effectiveness was rated as excellent in 24 cases, good in 3 cases, fair in 2 cases, and poor in 1 case.ConclusionFor tibial plateau fractures complicated with osteofascial compartment syndrome, simple Ilizarov ring external fixation technique can basically restore joint function and has fewer complications. It is a relatively safe and effective treatment method.

    Release date:2020-11-02 06:24 Export PDF Favorites Scan
  • A technique analysis for dissection of anterolateral thigh perforator flap

    Objective To improve the harvesting techniques of anterolateral thigh perforator flap, and to reduce the operation time. Methods Between January 2008 and June 2015, 400 patients undergoing repair with anterolateral thigh perforator flap were included to analyze the technical factors, including 370 cases (92.5%) obtaining primary healing and 30 cases (7.5%) receiving re-exploration. Combined with the literature, a modified flap dissection was made: reverse tracing and sequential dissection of the descending branch of the lateral circumflex femoral artery. Between June 2015 and June 2016, the modified free anterolateral thigh perforator flap was used in 100 cases. Of 100 cases, 76 were male and 24 were female, aged from 11 to 71 years (mean, 35.6 years). The wound size ranged from 8 cm×5 cm to 23 cm×9 cm. The time between injury and surgery ranged from 5 to 31 days (mean, 14.3 days). Results The operation time of modified flap dissection was reduced to (30.1±19.3) minutes from (85.0±30.2) minutes (unmodified flap dissection). Postoperatively, 94 flaps survived uneventfully, and incision healed by first intention. Six flaps received re-exploration surgery because of vascular compromise; the flap survived after removal of thrombosis in 4 cases of vein thrombosis; the flap necrosed in 2 cases of vein and artery thrombosis, and skin grafting was performed. Ninety-four patients whose flaps survived were followed up 3-12 months (mean, 6.3 months); the flaps had good color and appearance, and second stage operation was performed to make the flap thinner in 21 cases. Conclusion Improved harvesting technique of free anterolageral thigh perforator flap could decrease surgery time and difficulty in dissection.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
  • Application of self-made chronic wound closure device in the repair of scarred lower extremity wounds

    ObjectiveTo investigate the effectiveness of self-made limb chronic wound closure device in the treatment of scarred lower limbs and complex skin and soft tissue defects.MethodsBetween January 2014 and January 2017, 29 patients with complex fractures of the lower extremities and skin and soft tissue defects were treated. There were 19 males and 10 females with an average age of 31.1 years (range, 21-66 years). The causes of injury included 14 cases of traffic accidents, 5 cases of falling from height, 4 cases of heavy object crushing injury, 4 cases of mechanical crushing injury, and 2 cases of exposed steel plate after fracture. There were 26 cases of calf fracture and skin defect, 3 cases of metatarsal bone fracture and skin defect of the foot. The skin defect ranged from 5 cm×3 cm to 18 cm×8 cm. The time from injury to admission was 5-31 days, with an average of 14.3 days. All patients underwent a thorough debridement, open wound drainage, self-made chronic wound closure device combined with Ilizarov stretching technique for a slow skin and soft tissue traction. After the wound was cleaned up and the granulation tissue was freshened, the skins on both sides were closed, and then proceed to the second stage operation of skin grafting or direct suture closure based on the size of the wound.ResultsAll patients were followed up 8-20 months, with an average of 13 months. Twenty-nine patients were treated with self-made chronic wound closure device combined with Ilizarov technique for 1-2 times with an average of 1.3 times, then the wound infection was controlled and the granulation tissue grew well. In the course of treatment, the pain was not obvious and the patients had good compliance. All patients’ wounds healed clinically without skin traction complications and formed linear or flaky scars.ConclusionThe self-made chronic wound closure device is effective in repairing complex scarred wounds of lower extremities, and it is easy to operate.

    Release date:2019-01-25 09:40 Export PDF Favorites Scan
  • Anatomical calcaneal external fixator self-designed according to the morphology of heel

    ObjectiveThe anatomical calcaneal external fixator was designed by measuring and calculating the morphological data of the heel.MethodsA total of 100 normal people were randomly selected to obtain 200 hind foot data, including 45 males and 55 females, with an average age of 43.9 years (range, 19-67 years). According to the principles of human engineering and local anatomy, the morphological data of the heel in the weight-bearing standing position and supine position were measured with the direct measurement mode. The heel length, heel width, heel height, medial ankle height, lateral ankle height, and calcaneal pitch angle (CPA) were measured by vernier calipers and ulnar markers in weight-bearing standing position, and the gender groups and left and right foot groups were compared; the shape of the hind foot in the supine position was measured by three-dimensional (3D) dot matrix inverse model method. According to the stereoscopic data of the comprehensive anatomical morphology of the heel, the anatomical calcaneal external fixator was designed with AutoCAD 2019 and other 3D industrial design softwares.ResultsThe measurements of shoe size, heel length, heel width, heel height, medial ankle height, lateral ankle height, and CPA in male were significantly higher than those in female (P<0.05). There was no significant difference between the left and right feet in the other indexes except that the height of the medial malleolus of the left foot was significantly lower than that of the right foot (t=−2.827, P=0.005). The measurement of 3D dot matrix inverse model in supine position showed that the heel part was non-circular arc edge, and many groups of arc edges fluctuate in a limited range. Based on the above data, an anatomical calcaneal external fixator was designed, which could fit the anatomic radian in theory, so as to be flexible in configuration. On this basis, the ordinary configuration, compression configuration, and orthodontic configuration were designed to meet the treatment needs of calcaneal fractures in different degrees. The ordinary configuration was suitable for patients with Sanders Ⅰ, ⅡA, and ⅡB calcaneal fractures with no or slight displacement of intra-articular fractures; the ordinary configuration was mainly used for simple fixing. The compression configuration was suitable for patients with Sanders ⅡC, ⅢA, and ⅢB, tongue fractures, and avulsion fractures with severe displacement of intra-articular fractures; the compression configuration used obliquely drawn console wires to fix the displaced bones. The orthodontic configuration was suitable for patients with Sanders ⅢC and Ⅳ calcaneal fractures with severe displacement of intra-articular fractures or severe calcaneal bone defects; the orthodontic configuration was a multi-module design, which took into account the stable fixation of the fracture and the arbitrary adjustment of the joint fixation angle.ConclusionThe hind foot is special for morphology, so the external fixator designed based on the vernier caliper measurement method and 3D dot matrix measuring plate measurement method is an anatomical type and its configuration can theoretically meet stable and flexible clinical needs.

    Release date:2020-04-29 03:03 Export PDF Favorites Scan
  • Primarily application of Ilizarov microcirculation reconstruction technique for chronic wounds in post-traumatic ischemia limbs

    ObjectiveTo evaluate the treatment results of Ilizarov microcirculation reconstruction technique for chronic wounds in the post-traumatic ischemia limbs.MethodsBetween January 2016 and July 2019, 7 cases of chronic wounds in the post-traumatic ischemia limbs were treated. There were 5 males and 2 females, with an average age of 42.4 years (range, 29-66 years). The duration of the wound ranged from 1 month to 2 years (mean, 7.7 months). The wounds located in the leg (3 cases) or in the foot and ankle (4 cases). The wound sizes ranged from 4.0 cm×2.2 cm to 12.0 cm×7.1 cm. There were 1 case of tibial varus, 3 cases of equinovarus, 1 case of scleroderma, and 2 cases of Volkmann’s ischemic contracture. After debridement, external fixators were used for tibial transverse transport, or correction of tibial varus and correction of equinovarus.ResultsAll patients were followed up 8-20 months, with an average of 13 months. The infection of wound surface was all controlled in 7 cases and the granulation tissue grew well; the wound surface healed directly in 5 cases and healed after skin grafting in 2 cases, and the wound healing time was 1-3 months (mean, 1.7 months). During the follow-up, there was no recurrence of the wound. Six cases of limb deformity were corrected.ConclusionFor the chronic wounds in the post-traumatic ischemia limbs, Ilizarov microcirculation reconstruction technique can effectively improve local circulation and facilitate the fresh granule growth and wound healing.

    Release date:2020-08-19 03:53 Export PDF Favorites Scan
  • Clinical application of nose ring drain technique combined with Ilizarov circular external fixation for Gustilo ⅢA Pilon fractures

    ObjectiveTo investigate the effectiveness of the nose ring drain (NRD) technique combined with Ilizarov circular external fixation in treatment of Gustilo ⅢA Pilon fracture.MethodsBetween March 2017 and December 2019, 17 patients with Gustilo ⅢA Pilon fractures were admitted and treated with NRD technique combined with Ilizarov circular external fixation. Among them, there were 11 males and 6 females; the age ranged from 24 to 63 years, with an average of 38.2 years. There were 3 cases of traffic accident injury, 13 cases of falling injury, and 1 case of penetrating injury. There were 13 cases of emergency admittance and 4 cases of wound infection after surgical treatment. Furthermore, there were 2 cases of fibula fractures and 3 cases of lateral malleolus fractures. ResultsAll patients were followed up 8-12 months, with an average of 9.9 months. All wounds healed by first intention, and 4 patients with preoperative infection had no recurrence during the follow-up. The external fixator was removed after fracture healing in 17 patients at 3-7 months after operation (mean, 4.5 months). At last follow-up, the pain score of the ankle joint Kofoe score was 40-50, with an average of 44; the functional score was 17-27, with an average of 25; the mobility score was 8-18, with an average of 14; and the effectiveness was rated as excellent in 8 cases, good in 7 cases, and poor in 1 case.ConclusionFor Gustilo ⅢA Pilon fractures, the NRD technique combined with Ilizarov circular external fixation has advantages of good fracture fixation and drainage effects, which greatly reduces the complications of traditional treatment options and the number of operations.

    Release date:2021-02-24 05:33 Export PDF Favorites Scan
  • The association between prenatal exposure to dichlorodiphenyltrichloroethane(DDT) or polychlorinated biphenyls (PCBs) and the risk of congenital anomalies: a meta-analysis

    Objective To systematically review the association between prenatal exposure to dichlorodiphenyltrichloroethane (DDT) or polychlorinated biphenyls (PCBs) and the risk of congenital anomalies. Methods PubMed, EMbase, WanFang Data, VIP and CNKI databases were electronically searched to collect case-control studies on the relationship between prenatal exposure to DDT or PCBs and congenital anomalies from inception to February 2017. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies, then, meta-analysis was performed by using Stata 13.0 software. Results A total of 14 studies involving 2 238 infants with defect and 2 335 infants without defect were included. The results of meta-analysis showed that: the prenatal exposure to high level of DDT increased the incidence of cryptorchidism (OR=1.12, 95% CI 1.09 to 1.15, P<0.001). However, DDT exposure had no correlation to hypospadias and neural tube defects. The associations between prenatal exposure to PCBs and cryptorchidism, hypospadias, neural tube defects were not discovered. Conclusion Prenatal exposure to high levels of DDT may be a risk factor for cryptorchidism. Due to limited quality and quantity of the included studies, more high-quality studies are needed to verify above conclusion.

    Release date:2018-06-04 08:48 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content