Accurate measurements of voltage and current from electrosurgery are the basis of development of electrosurgery with feedback function. We, therefore, developed a parameter measurement system based on PC, with high voltage and current from electrosurgery being sensed with transformers, amplified, filtered, transformed into single-ended signals, and then into RMS signals. The root mean square (RMS) signals were transformed into digital signals through DAQ card and the data was processed in PC with Labview. The process included sampling, displaying and storage. The experiment results indicated that the measurement system could measure the output parameters from electrosurgery steadily and correctly so that the development of the system has been successful. It can be the basis of development of embedded parameters measurement system and can provide accurate feedback information for intellectual electrosurgery.
ObjectiveTo evaluate the effectiveness of posteromedial double plates in the treatment of complex olecranal fracture. MethodsBetween September 2011 and July 2015, 13 patients with complex olecranal fractures were treated with posterior olecranon locking compression plate and medial mini-plate. There were 8 males and 5 females with an average age of 41.6 years (range, 22-68 years). Injury was caused by traffic accident in 4 cases, falling from height in 6 cases, and crush by object in 3 cases. According to the Mayo classification, fracture was rated as Mayo type ⅡB in 5 cases and as Mayo type ⅢB in 8 cases. Of 13 cases, 7 had Regan-Morrey type Ⅲ coronoid fractures, including 5 anterior dislocations of the elbow joint and 2 posterior dislocations. The time between injury and admission ranged from 1.5 to 10.0 hours (mean, 5.7 hours). At last follow-up, the elbow function was assessed according to the Broberg-Morrey evaluation criteria. X-ray films was performed to observe fracture healing. ResultsAll incisions healed at first stage and no neural complications occurred. The patients were followed up 9-38 months (mean, 22.1 months). All patients achieved bone union at 3.0-5.5 months (mean, 3.7 months) according to X-ray results. Subluxation of radial head and mild heterotopic ossification occurred in 1 patient respectively, who had no uncomfortable symptoms of movement disorder, elbow instability and pain, and no special management was performed. At last follow-up, the flexion and extension range of motion (ROM) of the elbow was 95-130° (mean, 116.4°); the rotation ROM of the forearm was 150-175° (mean, 170.8°); and the elbow function was excellent in 4 cases, good in 7 cases, and fair in 2 cases, and the excellent and good rate was 84.6%. No internal fixation failure, elbow stiffness, or traumatic arthritis occurred. ConclusionFor complex olecranal fractures, an early and stable anatomic reconstruction of trochlear notch in the olecranon with posterior olecranon locking compression plate and medial mini-plate can obtain good effectiveness in joint functions.
ObjectiveTo systematically review the efficacy and safety of plasma exchange (PE) versus routine medical therapy (RMT) for patients with chronic liver failure. MethodsWe electronically searched databases including PubMed, The Cochrane Library (Issue 7, 2014), CBM, CNKI, and VIP from inception to August 2014, to collect randomized controlled trials (RCTs) and clinical controlled trials (CCTs) of PE versus RMT for chronic liver failure patients. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed using RevMan 5.0 software. ResultsA total of 7 RCTs and 9 CCTs involving 1 632 patients (822 in the PE group and 810 in the RMT group) were included. The results of meta-analysis showed that:compared with the RMT group, the PE group had lower mortality rate (RCT:OR=0.24, 95%CI 0.13 to 0.43; CCT:OR=0.48, 95%CI 0.30 to 0.78) and higher total effective rate (RCT:OR=4.04, 95%CI 2.80 to 5.85; CCT:OR=3.45, 95%CI 2.11 to 5.64). Subgroup analysis based on the stage of liver failure showed that the PE group was superior to the RMT group in early- and intermediate-stage patients with liver failure in total effective rate (early stage:OR=4.78, 95%CI 1.87 to 12.23; intermediate stage:OR=4.43, 95%CI 1.77 to 11.08), but this difference was not found in advanced liver failure patients (OR=1.61, 95%CI 0.35 to 7.38). Seven studies reported 187 cases of adverse reactions (11.46%), and most of them were pruritus and urticaria. ConclusionCurrent evidence shows, compared with the routine medical therapy, the PE therapy could be effective to early- and intermediate-stage liver failure patients, but not be effective to advanced liver failure patients. In addition, patients who received the PE therapy have risks of adverse reactions which mainly are allergic reaction. Due to limited quality and quantity of the included studies, more high quality studies are needed to verify the above conclusion.
ObjectiveTo research the effect of different surgical sutures on abdominal surgical incision healing quality, and provide a novel theory basis for promoting the healing of incision of abdominal wall. MethodsTotally 341 patients who underwent laparotomy were collected from general surgery of Affiliated Hospital of North Sichuan Medical College, and they were randomly divided into three groups: the including polydioxanoneⅡ(PDSⅡ) suture group, abdominal wall incision except the skin was successively sutured with PDSⅡsuture; the Vicryl group, abdominal wall incision except the skin was successively suture with antibacterial Vicryl; and the common silk thread group, abdominal wall incision was performed layering intermittent silk suture. ResultsIn terms of suture time, the PDSⅡsuture group [(11.23±1.62) min〕was significantly lower than the Vicryl group [(14.04±1.20) min〕, P < 0.05, and also both were significantly lower than the ordinary silk thread group [(21.95±1.95) min〕, P < 0.05. In respect of rejection reaction, incision infection and incision split, the PDSⅡsuture group and the Vicryl group were significantly lower than the ordinary silk thread group (P < 0.05), but compared the PDSⅡsuture group with the Vicryl group, the differences were not statistically significant (P > 0.05). Regarding post operation hospitalization duration, fat liquefaction and effusion, compared the differences between the three groups were not statistically significant (P > 0.05). ConclusionFull fascia is successively suture with PDSⅡsutures and antibacterial Vicryl suture that can significantly shorten the suture time, reduce the incidence of rejection incision, wound infection and wound dehiscence and promote the postoperative recovery of the patients.
ObjectiveTo evaluate the effectiveness of acellular dermal matrix (ADM) with autologous buccal micro mucosa and micro skin graft in vaginoplasty. MethodsA retrospective analysis was made on the clinical data of 67 patients with vaginal agenesis treated between July 2006 and June 2013. ADM and mixed particles were used in 20 cases (ADM group) and mixed particles graft in 47 cases (control group) in vaginoplasty. There was no significant difference in age between 2 groups (t=0.233, P=0.816). The depth, diameter, and volume of neovagina, epithelization time, stent needing time, and female sexual function index (FSFI) score were compared between 2 groups. ResultsThere was no significant difference in operation time and amount of bleeding between 2 groups (t=-1.922, P=0.059; t=0.398, P=0.692). The patients were followed up 11-38 months (mean, 16.08 months). Fifteen cases in ADM group and 29 cases in control group had sexual life after operation. Bleeding after operation occurred in 6 cases (2 in ADM group and 4 in control group). No stenosis was observed. Difference in epithelization time was not statistically significant (t=-1.938, P=0.057). However, the stent needing time of ADM group was significantly shorter than that of control group (t=7.020, P=0.000). The neovagina was ideal in wetness degree, smoothness, flexibility, and hairlessness during follow-up. The depth, diameter, and volume of vagina had no significant difference between 2 groups (P>0.05) at last follow-up, which were close to normal vagina. The other patients had normal sexual function except 1 patient whose FSFI score was less than 23; no statistically significant difference was found in FSFI score between 2 groups (P>0.05). ConclusionOn the basis of mixed particles grafting, the ADM could improve trestle structure for resisting contracture. The effectiveness is better than merely mixed particles graft. The procedure has satisfactory anatomical and functional results.
ObjectiveTo systematically review the diagnostic accuracy of C-arm cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) for lung nodules. MethodsWe electronically searched databases including PubMed, EMbase, EBSCO, Ovid, CBM, VIP, WanFang Data and CNKI from inception to Feb 28th, 2015, to collect diagnostic studies of CBCT-guided PTNB for lung nodules. Two reviewers independently screened literature, extracted data and assessed the methodological quality of included studies by QUADAS-1 tool. Then, meta-analysis was performed by Stata 12.0 and Meta-DiSc 1.4 softwares for calculating pooled sensitivity (Sen), specificity (Spe), positive likelihood ration (+LR), negative likelihood ration (-LR), and diagnostic odds ratio (DOR), drawing summary receiver operating characteristic (SROC) curve and estimating area under the curve (AUC). ResultsA total of 9 studies involving 1 815 patients were included. The results of meta-analysis showed that the pooled Sen, Spe, +LR,-LR, and DOR were 0.95 (95%CI 0.92 to 0.96), 1.00 (95%CI 0.66 to 1.00), 2 076.58 (95%CI 1.8 to 2.3e+0.6), 0.05 (95%CI 0.04 to 0.08), and 39 443.88 (95%CI 30.53 to 5.1e+0.7), respectively. The AUC of SROC was 0.97 (95%CI 0.95 to 0.98). ConclusionCBCT-guided PTNB can be used as one of the primary examination approaches for lung nodules with relatively high diagnostic accuracy. Due to limited quality and quantity of the included studies, more high quality studies are needed to verify the above conclusion.
Objective To investigate the protective effect of 4-phenylbutyric acid (PBA) on liver injury induced by severe acute pancreatitis (SAP) in rats and its possible mechanism. Methods Twenty-four SPF adult male Sprague Dawley rats were randomly divided into three groups: shame operation group (SO group,n=8), SAP group (n=8), and PBA group (n=8). SAP model was induced by retrograde injection of 5% sodium taurocholate (1 mL/kg) in biliopancreatic duct in SAP group and PBA group. PBA solution (50 mg/kg) was administeredvia intraperitoneal injection for 3 days prior to establishing models in PBA group. Rats were injected equivalent saline solution instead of PBA solution in SAP group and SO group. All rats were sacrificed at 12 h after modeling. Blood samples were collected by inferior vena cava puncture, and serum levels of amylase (AMY), alanine aminotransferase (ALT), and aspartate transaminase (AST) were measured using a fully automatic chemistry analyzer. The head of pancreas and right lobe of hepatic tissues were harvested and pathological examination was observed under the light microscope. Expressions of glucose-regulated protein 78 (GRP78), CCAAT/enhancer binding protein homologous protein (CHOP) and Caspase-3 in hepatic tissues were evaluated by immunohistochemistry assay. Results Compared with SO group, the serum levels of AMY, ALT and AST were significantly increased in SAP group (P<0.05). The serum levels of ALT and AST in PBA group were significantly lower than those in SAP group (P<0.05). There was no difference of the serum levels of AMY between in PBA group and SAP group (P>0.05). Compared with SO group, the damages of the pancreas and liver tissues and the expressions of GRP78, CHOP and Caspase-3 in hepatic tissues were significantly increased in SAP group (P<0.05). And the above indices in PBA group were significantly decreased when compared with SAP group. Conclusions PBA can alleviate severe acute pancreatitis-induced liver injury, and the mechanism may be associated with inhibition of endoplasmic reticulum stress (ERS) and reduction of hepatocyte apoptosis.
ObjectiveTo explore the diagnostic value of CT-guided percutaneous needle aspiration biopsy (PTNB) for ground-glass opacity (GGO) pulmonary lesions. MethodsA retrospective design was used to collect clinical data of patients with GGO lesions admitted in the Affiliated Hospital of North Sichuan Medical College between Jan. 2009 to Jan 2015. Patients were divided into groups according the lesion size (≤10 mm, 10-20 mm,≥20 mm), length of needle path (≤5 cm, 5-9 cm,≥9 cm) and percentage of GGO component (50%-90%, >90%), respectively. The total and subgroups of sensitivity, specificity, and diagnostic accuracy of CT guided PTNB for diagnosing GGO were calculated and the differences among subgroups were compared using Fisher's exact test. Statistical analysis was conducted by using SPSS 17.0 software. ResultsA total of 60 patients involving 48 malignant and 12 benign lesions were included. The total sensitivity, specificity, and accuracy of CT guided PTNB for diagnosing GGO were 87.5%, 100% and 90%, respectively. There were no significant differences among the subgroups based on the lesion size, length of needle path, and percentage of GGO component (all P values >0.05). ConclusionCT-guided PTNB can be used as one of the diagnostic modalities for lung GGO lesions with a moderate diagnostic value.