west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHU Bin" 5 results
  • Therapeutic Effects of Compound Danshen with Cmetidine on Anaphylactoid Purpura

    摘要:目的:探讨复方丹参加西咪替丁治疗过敏性紫癜(HSP)临床疗效。方法:60例患儿随机分为对照组和治疗组各30例。对照组常规治疗,治疗组加用复方丹参和西咪替丁治疗。结果:治疗组总有效率为90.0%,明显高于对照组53.3%,且治疗组紫癜性肾炎(HSPN)发生率(10.0%)明显低于对照组(36.7%),Plt;0.01。结论:复方丹参加西咪替丁能提高HSP患儿疗效,减少肾损害,促进患儿病情康复。

    Release date:2016-09-08 09:56 Export PDF Favorites Scan
  • EFFECT OF DEACETYLATION DEGREE OF CHITOSAN ON THERMOSENSITIVE HYDROGEL VIA RHEOLOGICAL CHARACTERIZATION/

    To evaluate the effect of deacetylation degree (DDA) on the gelation behavior of thermosensitive chitosan-β glycerol phosphate disodium salt pentahydrate (CH-GP) system and to compare their rheological behaviors before and after gelation. Methods A series of thermosensitive CH-GP samples with different DDAs (70%, 85%, 90%, 97%)were prepared by dissolving CH with 0.1 mol/L HCl solution, 5 samples for every single DDA, and then all these CH-GP solution samples processed the frequency sweep test and temperature sweep test (10-70℃ , 1℃ /min) on AR 2000ex rheometer, with pH value of 7.02. Also, all the results of hydrogel samples were processed a frequency sweep test. Results With CH concentration of 2% (w/v) and pH value of 7.02 , the gelating temperature of CH-GP systems with different DDAs (85%, 90%, 97%) were (59.90 ± 0.08), (48.10 ± 0.08), (37.10 ± 0.11) ℃ , respectively. While the gelating temperature of CH-GP system with 70% DDA was over 70℃ . There were statistically significant differences in temperature and time of gelation among groups with different DDAs (P lt; 0.05). Furthermore, storage modulus of such system raised from dozens Pa to a magnitude of several kPa during gelation , while loss modulus kept almost steady. Conclusion Gelating temperature and mechanical property of the system could be measured objectively by rheological characterization. Thus during designing tissue engineered scaffolds for various purposes, it is helpful applying selected CH with optimal DDA to different target tissues.

    Release date:2016-09-01 09:14 Export PDF Favorites Scan
  • In vivo biological safety study of porous zinc oxide/hydroxyapatite composite materials

    ObjectiveTo evaluate the in vivo biological safety of porous zinc oxide (ZnO)/hydroxyapatite (HA) composite materials.MethodsThe porous ZnO/HA composite materials and porous HA materials were prepared by the spark plasma sintering technology. First, the materials were characterized, including scanning electron microscopy to observe the material structure, in vitro degradation experiments to detect the degradation rate of the materials, and inductively coupled plasma emission spectrometer to detect the concentration of Zn2+ dissolved out of the composite material degradation. Then the two kinds of material extracts were prepared for acute systemic toxicity test. Fifteen male Kunming mice were randomly divided into groups A, B, and C (n=5) and injected intraperitoneally with normal saline, HA extracts, and ZnO/HA extracts, respectively. The body mass of the mice was recorded before injection and at 24, 48, and 72 hours after injection. The liver and kidney tissues were taken at 72 hours for HE staining to evaluate the safety of the composite material. Finally, the biological safety of the material in vivo was evaluated by implantation experiment. The eighteen male New Zealand white rabbits were randomly divided into HA group and ZnO/HA group (n=9); a bilateral radius defect model (1 cm) was established, and the right forelimbs of the two groups were implanted with porous HA materials and porous ZnO/HA composite materials, respectively; the left untreated as a blank control. The general condition of the animals were observed after operation. The rabbit blood was collected at 1 day before operation and at 1 day, 1 week, 4 weeks, and 8 weeks after operation for routine blood test (inflammation-related indicators) and blood biochemistry (liver and kidney function-related indicators). X-ray films were taken at 4, 8, and 12 weeks after operation to observe the repair of bone defects.ResultsMaterial characterization showed that porous ZnO/HA composite materials had interconnected large and small pore structures with a pore size between 50 and 500 μm, which degraded faster than porous HA materials, and continuously and slowly dissolved Zn2+. The acute systemic toxicity test showed that the mice in each group had no abnormal performance after injection, and the body mass increased (P<0.05). HE staining showed that the cells shape and structure of liver and kidney tissue were normal. Animal implantation experiments showed that all rabbits survived until the experiment was completed; routine blood tests showed inflammation in each group (neutrophils, monocytes, and lymphocytes increased) at 1 day after operation, and all returned to normal at 8 weeks (P>0.05); compared with 1 day before operation, the content of inflammatory cells in the HA group increased at 1 day, 1 week, and 4 weeks after operation (P<0.05), and the ZnO/HA group increased at 1 day after operation (P<0.05); blood biochemistry showed that the liver and kidney function indexes were in the normal range; X-ray films showed that the ZnO/HA group had better osseointegration than the HA group at 4 weeks after operation.ConclusionThe porous ZnO/HA composite material has good in vivo biological safety and good bone repair ability, which is a potential bone repair material.

    Release date:2021-06-30 04:43 Export PDF Favorites Scan
  • Expression and Significance of Phosphoinositide 3-Kinase and Phosphorylated Protein Kinase B in Bladder Urothelial Carcinoma

    目的 研究磷脂酰肌醇3-激酶(PI3K)和磷酸化蛋白激酶B(p-Akt)在人膀胱尿路上皮癌组织中的表达特征及临床意义。 方法 2005年6月-2010年7月,采用免疫组织化学法检测40例膀胱尿路上皮癌组织及10例正常膀胱组织PI3K与p-Akt的表达,并对结果进行统计学分析。 结果 PI3K和p-Akt在正常膀胱黏膜组织阳性表达率均低于膀胱尿路上皮癌组织中,差异均有统计学意义(P<0.05)。同一标本中PI3K和p-Akt的表达不具有相关性(r=0.051,P=0.747)。 结论 PI3K、p-Akt在膀胱尿路上皮癌中高表达,两者在膀胱尿路上皮癌中共同促其发展,但其在膀胱尿路上皮癌的预后和进展中的作用尚不明确。

    Release date:2016-09-08 09:13 Export PDF Favorites Scan
  • Patellar Resurfacing versus Non-resurfacing in Totol Knee Arthroplasty: A Systematic Review

    Objective To compare the treatment effect of patellar resurfacing versus patellar non-resurfacing in total knee arthroplasty. Methods We identified eligible studies in PubMed (1950 to 2008.6), OVID MEDLINE (1950 to 2008.6), OVID CINAHL (1950 to 2008.6), OVID EBM (2nd Quarter 2008), CBMdisk (1978 to 2008.6), and CNKI (1981 to 2008.6), and handsearched some Chinese orthopedic journals to identified randomize controlled trials (RCTs) comparing patellar resurfacing versus patellar non-resurfacing in total knee arthroplasty. Data were extracted and methodological quality was critically assessed by two reviewers independently. Meta-analyses were performed using Stata 10.0 software. Outcomes of interest included the number of reoperations for patellofemoral problems, the prevalence of postoperative anterior knee pain, and the improvement in HSS knee score. Results Thirteen RCTs involving 1 566 patients were included. The scores of methodological quality respectively were more than 13. The results of meta-analyses showed that patellar resurfacing could decrease the re-operation rate for patellofemoral problems (RR=0.30, 95%CI 0.14 to 0.62, Plt;0.01). The rate of postoperative anterior knee pain and the improvement in HSS knee score were comparable between patellar resurfacing and patellar non-resurfacing. Conclusion The outcome identified is re-operations for patellofemoral problems. The resurfaced patella performs better, and we find an increased relative risk for re-operation when the patella is left un-resurfaced. No differences are observed between the two groups for the prevalence of postoperative anterior knee pain, and the improvement in HSS knee score. Further well-designed and large-scale RCTs are required to determine the effects of patellar resurfacing and non-resurfacing on these outcomes.

    Release date:2016-09-07 02:08 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content