west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHUQingtang" 2 results
  • EXPERIMENTAL STUDY ON EFFECT OF POWER-ASSISTED INTRAVASCULAR SHUNT IN REPLANTATION OF AMPUTATED LIMBS IN RABBITS

    ObjectiveTo investigate the effect of power-assisted intravascular shunt in replantation of amputated limbs of rabbits. MethodsEighty rabbits weighing 1.8-2.5 kg (male or female) were selected to establ ish the model of circular amputation at the hind groin, only femoral arteries and veins were completely preserved. After the femoral artery was clamped in 60 rabbits, the rabbits underwent power-assisted intravascular shunt with high-flow rate (group A, n=20), powerassisted intravascular shunt with low-flow rate (group B, n=20), and no power-assisted intravascular shunt (group C, n=20) to reconstruct blood supply; the femoral artery was not clamped in another 20 rabbits of sham group (group D). Before and after intravascular shunt (1, 3, 6, and 12 hours), the malondialdehyde (MDA), lactate dehydrogenase (LDH), and creatine kinase (CK) of the serum were determined. The myeloperoxidase (MPO), MDA, and wet to dry weight ratio (W/D ratio) of the gastrocnemius muscle were measured, and the thrombogenesis and survival rate of limb were observed. ResultsBefore intravascular shunt, MDA, LDH, and CK of the serum and MPO, MDA, and W/D ratio of the muscle showed no significant difference among 4 groups (P>0.05). At each time point after intravascular shunt, no significant difference was found in all indexes between groups A and D (P>0.05); the indexes of groups B and C were significantly higher than those of groups A and D (P<0.05); the values were the highest in group C (P<0.05), and reached the peak at 12 hours. All limbs of group A survived with low thrombosis rate, and less limbs could survive with high thrombosis rate in group C. ConclusionThe power-assisted intravascular shunt with high-flow rate can effective ensure the blood supply of the amputated limbs of rabbits with lower limb injury and higher survival rate of amputated limbs after replantation.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF PROXIMAL HUMERAL INTERNAL LOCKING SYSTEM PLATE FOR PROXIMAL HUMERUS FRACTURES

    ObjectiveTo analyze the effectiveness of proximal humeral internal locking system (Philos) plate for proximal humerus fracture. MethodsThirty-three patients with proximal humerus fracture were treated with open reduction and internal fixation with Philos plate between January 2009 and January 2014. There were 19 males and 14 females, aged 23-89 years (mean, 56.6 years). The left side was involved in 15 cases, and the right side in 18 cases. The injury causes included falling in 20 cases and traffic accident in 13 cases. All cases received X-ray and CT scan and three-dimensional reconstruction before operation. According to the Neer classification, 8 cases were rated as two-part fractures, 15 cases as three-part fractures, and 10 cases as four-part fractures. The interval time between injury and surgery was 1-7 days (mean, 3.67 days). Postoperative functional outcome was evaluated using the Constant-Murley score. ResultsInfection and liquefaction occurred in 2 cases respectively, which was cured after corresponding treatment; primary healing of wound was obtained in the other 29 cases. Five patients had shoulder pain. The patients were followed up 11-47 months (mean, 33 months). The mean time of fracture union was 7.5 months (range, 5-9 months) on the X-ray films. Humeral head necrosis occurred in 2 patients with Neer four-part fractures, and internal fixation failure occurred in 3 patients (2 screw broken and 1 plate broken) with four-part fractures (2 cases) and three-part fractures (1 case), which was cured after conservative treatment. At last follow-up, the mean Constant-Murley score was 70.5 (range, 42-90); the results were excellent in 3 cases, good in 21 cases, moderate in 6 cases, and poor in 3 cases. ConclusionSatisfactory results can be expected for proximal humeral fracture by using of the proximal humeral internal locking system plate based on strict indication and early rehabilitation training.

    Release date:2016-10-21 06:36 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content