west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZhaoJin" 2 results
  • The Influence of Different Concentrations of Iodinated Contrast Agent on Image Quality of Galactography

    ObjectiveTo explore the influence of different concentrations of iodinated contrast agent on image quality of galactography. MethodsBetween June 2008 and October 2009, 50 non-pregnancy and non-lactation patients with mammary papilla discharge underwent breast galactography with digital mammography. All the patients' left breasts were in group L, and right breasts were in group R. The iohexol concentration of iopamidol injection was 370 mg/mL in group L and 300 mg/mL in group R. The image quality and the evaluation of average density of the two groups was analyzed and compared. ResultsThe image quality score of group L and R was 2.8±0.2 (P>0.05). The mean density of main duct of breast axial view in two groups was (4 020.25±96.26) and (3 984.75±117.67) HU, respectively; the mean density of the lateral oblique view was (4 067.13±24.69) and (3 971.25±167.32) HU, respectively; the mean density of the lateral view was (4 058.88±52.07) and (4 034.75±67.54) HU, respectively. There was no significant difference between the two groups (P>0.05). ConclusionNo obvious difference between the two concentrations of non-ionic iodinated contrast agents (300 and 370 mg/mL) in galactography diagnosis is found.

    Release date: Export PDF Favorites Scan
  • The Application of 70 kV and Sonogram-affirmed Iterative Reconstruction Technique in CT Examination for Children with Congenital Heart Disease

    ObjectiveTo evaluate the value of 70 kV and sonogram-affirmed iterative reconstruction technique in CT examination for children with congenital heart disease. MethodsThirty children with congenital heart disease who underwent CT scan between January and September 2014 were included in this study. According to the different tube voltage, they were randomly divided into group A (80 kV) and group B (70 kV), with fifteen in each. All the children were scanned on a dual-source-CT (Siemens Definition Flash). Group A used filtered back projection reconstruction. Group B used sonogram-affirmed iterative reconstruction. We measured and calculated the pulmonary artery signal-to-noise ratio at the level of main pulmonary artery window, the signal-to-noise ratio of the ascending aorta, noise ratio contrast between the pulmonary artery and erector spinae and between the ascending aorta and erector spinae. The image quality for congenital heart disease was assessed by two senior radiologists. The measurement of radiation dose included effective dose (ED), volume CT dose index (CTDIvol) and dose length product (DLP). ResultsThere were no significant differences between group A and B in terms of pulmonary artery signal-to-noise ratio (14.54±3.77, 11.23±2.52), the signal-to-noise ratio of the ascending aorta (14.76±3.41, 12.31±3.47), the noise ratio contrast between pulmonary artery and erector spinae (12.04±3.96, 9.18±3.76) and between the ascending aorta and erector spinae (12.47±4.59, 9.77±4.41) (P > 0.05). There was significant difference between group A and group B in CTDIvol[(0.53±0.09), (0.38±0.03) mGy], DLP[(12.93±1.79), (6.67±0.72) mGy·cm], and ED[(0.34±0.05), (0.17±0.02) mSv] (P < 0.05). ConclusionThe application of 70 kV and sonogram-affirmed iterative reconstruction technique in CT examination for children with congenital heart disease can significantly reduce the radiation dose without any influence on image quality.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content