west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "cannulated screw" 15 results
  • EXPERIMENTAL STUDY ON TREATMENT OF LATERAL FEMORAL CONDYLE FRACTURE WITH POLYLACTIC-CO-GLYCOLIC ACID/HYDROXYAPATITE ABSORBABLE CANNULATED SCREWS IN CANINE

    Objective To evaluate the internal fixation effect, degradation, and biocompatibility of polylactic-co-glycolic acid/hydroxyapatite (PLGA/HA) absorbable cannulated screws in treatment of lateral femoral condyle fracture of canine so as to provide the theory basis for their further improvement and clinical application. Methods Sixteen adult male Beagles (weighing, 9-12 kg) were selected to prepare the models of bilateral lateral femoral condyle fracture; left fracture was fixed with PLGA/HA absorbable cannulated screws as experimental group and right fracture with metal screws as control group. At 2, 4, 8, and 12 weeks after operation, general observation was done and X-ray films were taken for observing fracture healing; bone mineral density was measured; the histological examination was performed; and the degradation property of absorbable cannulated screws was detected. Results All animals survived to the end of the experiment. General observations showed that no fracture displacement occurred and fracture healed at 12 weeks in 2 groups; no breakage, displacement, or loosening of screws was observed in experimental group. X-ray films results showed that the absorbable cannulated screws could not be found out by X-ray in experimental group, but metal screws could be found out in control group; fracture healed with time in 2 groups. The bone mineral density reached the peak at 8 weeks in 2 groups, and no significant difference was found between 2 groups and among different time points in the same group (P gt; 0.05). Histological examination showed that 2 groups had similar fracture healing process at different time points; no obvious inflammatory reaction was found around absorbable cannulated screws in experimental group. The degradation results of absorbable cannulated screws showed that the intrinsic viscosity and molecular weight distribution obviously decreased at 2 weeks; the number average molecular weight and the weight average molecular weight markedly decreased at 4 weeks; and the maximum shear force did not decrease obviously at 8 weeks, and then decreased significantly. Significant differences were found in all indexes among different time points in the same group (P lt; 0.05). Conclusion PLGA/HA absorbable cannulated screws and metal screws show similar fracture healing process for fixing lateral femoral condyle fracture of canine, and the absorbable canulated screws have good biocompatibility. The maximum shear force of PLGA/HA absorbable cannulated screw has no obvious decrease during 8 weeks after operation, so it can ensure full healing of fracture.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • Efficacy of Percutaneous Cannulated Screw versus Plate Fixation for Ankle Fractures: A Meta-analysis

    ObjectiveTo systematically review the efficacy of percutaneous cannulated screw (PCS) versus plate fixation (PF) in the treatment of ankle fractures. MethodsThe Cochrane Library (Issue 5, 2014), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched up to May 28th 2014, for studies concerning the efficacy of percutaneous cannulated screw versus plate fixation for ankle fractures. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using RevMan 5.1 software. Result A total of 10 studies (3 RCTs and 7 CCTs) involving 627 patients were included. The results of meta-analysis showed that:compared with the PF group, the PCS group was superior in time of the operation (RCT:MD=-6.78, 95%CI -11.95 to -1.60, P=0.01; CCT:MD=-9.76, 95%CI -13.68 to -5.84, P<0.000 01), blood loss during the operation (RCT:MD=-36.14, 95%CI -40.02 to -32.17, P<0.000 01; CCT:MD=-34.80, 95%CI -37.78 to -31.81, P<0.000 01) and the time of the fracture healing (RCT:MD=-1.16, 95%CI -1.51 to -0.81, P<0.000 01; CCT:MD=-1.55, 95%CI -2.97 to -0.13, P=0.03); However, there were no statistical differences between the two groups in complication rate (CCT:OR=0.48, 95%CI 0.08 to 2.81, P=0.41), AOFAS score excellent rate (RCT:OR=2.11, 95%CI 0.81 to 5.49, P=0.12; CCT:OR=1.58, 95%CI 0.75 to 3.30, P=0.23), and postoperative malleolus pain rate (CCT:OR=0.68, 95%CI 0.00 to 148.82, P=0.89). ConclusionCurrent evidence shows that PCS is superior to PF in shorting time of the operation, reducing blood loss during the operation, and shorting time of the fracture healing. However, the complication rate, AOFAS score excellent rate, and postoperative malleolus pain rate are similar for each operation. Due to the quality limitation of the CCTs, the conclusion are needed to be verified by more high quality RCTs in future.

    Release date: Export PDF Favorites Scan
  • CLINICAL RESEARCH OF INDIVIDUAL PERCUTANEOUS CANNULATED SCREWS FIXATION FOR TREATMENT OF Herbert TYPE Ib SCAPHOID FRACTURE

    ObjectiveTo investigate the effectiveness of individual percutaneous cannulated screws fixation of computer-assisted design combined with three-dimensional (3D) guide plate by comparing with cast immobilization and open internal fixation for treatment of Herbert type Ib scaphoid fracture. MethodsBetween January 2010 and June 2015, 56 patients with fresh Herbert type Ib scaphoid fracture were treated with cast immobilization in 16 cases (external fixation group), with open reduction and internal fixation in 20 cases (open reduction group), and with individual percutaneous cannulated screws fixation of computer-assisted design combined 3D guide plate in 20 cases (minimal invasion group). There was no significant difference in gender, age, injury cause, side, disease duration, and classification of fractures between groups P>0.05).The time of bone union, bone nonunion rate, return-to-work time, wrist range of motion (ROM), and Mayo function score were recorded and compared. ResultsPrimary healing of incision was obtained in open reduction group and minimally invasion group, without related complications. The cases were followed up 10-24 months (mean, 16.6 months). The time of bone union and return-to-work time of minimal invasion group were significantly shorter than those of the other 2 groups (P<0.05), and the rate of bone nonunion was significantly lower than that of the other 2 groups (P<0.05). At last follow-up, the wrist ROM of minimal invasion group[(104.40±3.46)°] was significantly larger than that of external group[(94.20±2.42)°] and open reduction group[(96.40±2.66)°] (P<0.05). According to Mayo function score, the results were excellent in 6 cases, good in 5 cases, fair in 2 cases, and poor in 3 cases in external fixation group, with an excellent and good rate of 69%; the results were excellent in 9 cases, good in 7 cases, fair in 2 cases, and poor in 2 cases in open reduction group, with an excellent and good rate of 80%; the results were excellent in 16 cases, good in 3 cases, and fair in1 case in minimal invasion group, with an excellent and good rate of 95%; there was significant difference in excellent and good rate among groups (P<0.05). ConclusionIndividual percutaneous cannulated screws fixation of computer-assisted design combined with 3D guide plate has satisfactory effectiveness in the treatment of Herbert type Ib scaphoid fractures, with the advantages of mini-invasion, high accuracy, high rate of bone union, less complication, early return-to-work time.

    Release date:2016-10-21 06:36 Export PDF Favorites Scan
  • Clinical application of computer-assisted cannulated screw internal fixation system based on error correction method for femoral neck fractures

    Objective To investigate the clinical efficacy of computer-assisted cannulated screw internal fixation system based on error correction method for femoral neck fractures. Methods A retrospective analysis was made on the clinical data of 20 femoral neck fracture patients treated by computer-assisted cannulated screw internal fixation system based on error correction method between January 2014 and October 2015 (trial group), and 36 femoral neck fracture patients undergoing traditional manual surgery with closed reduction by cannulated screw fixation in the same period (the control group). There was no significant difference in gender, age, injury cause, side of fracture, types of fracture, and time from injury to operation between 2 groups (P>0.05). The operation time, intraoperative blood loss, intraoperative frequency of fluoroscopy and guide pin insertion, fracture healing time, fracture healing rate, and Harris hip score were compared between 2 groups. Results All incisions healed by first intention after operation, and no complication of blood vessel and nerve injury occurred. The operation time of trial group was significantly longer than that of control group (t=2.290,P=0.026), however, the intraoperative blood loss, intraoperative frequency of fluoroscopy and guide pin insertion of trial group were significantly less than those of control group (t=–10.650,P=0.000;t=18.320,P=0.000;t=–16.625,P=0.000). All patients were followed up 12-18 months (mean, 14.7 months). X-ray films showed that fracture healing was obtained in 2 groups, showing no significant difference in fracture healing time between 2 groups (t=0.208,P=0.836). No complication of ischemic necrosis of femoral head occurred during follow-up period. At last follow-up, the Harris hip score was 87.05±3.12 in trial group and was 86.78±2.83 in control group, showing no significant difference (t=0.333,P=0.741). Conclusion Computer-assisted cannulated screw internal fixation surgery based on error correction method for femoral neck fractures is better than traditional manual surgery in decreasing intraoperative radiation and surgical trauma during operation.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • Application of three-dimensional printing technology for closed reduction and percutaneous cannulated screws fixation of displaced intraarticular calcaneus fractures

    Objective To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation. Methods A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores. Results The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference between at immediate after operation and last follow-up (P>0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%. Conclusion 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • Treatment of Day type Ⅱ pelvic crescent fracture by using percutaneous cannulated screw fixation technique

    ObjectiveTo evaluate the feasibility and effectiveness of percutaneous cannulated screw fixation for the treatment of Day type Ⅱ pelvic crescent fracture.MethodsThe clinical data of 14 patients with Day type Ⅱ pelvic crescent fractures underwent closed reduction and percutaneous cannulated screw fixation between January 2009 and July 2016 were retrospectively analysed. There were 9 males and 5 females, aged 17-65 years (mean, 38 years). The causes of injury included traffic accident in 8 cases, falling from height in 3 cases, bruise injury in 3 cases; all were closed fractures. According to Tile classification, there were 8 cases of type B, 6 cases of type C. There were 13 cases combined with fracture of the anterior pelvic ring, including 8 cases of superior and inferior ramus of pubis fracture, 1 case of superior ramus of pubis fracture with symphysis separation, and 4 cases of symphysis separation. The interval of injury and admission was 1- 72 hours (mean, 16 hours), and the interval of injury and operation was 3-8 days (mean, 5 days). After operation, the reduction of fracture was evaluated by the Matta evaluation criteria, the clinical function was assessed by Majeed function assessment.ResultsThe operation time was 35-95 minutes (mean, 55 minutes), cumulative C-arm fluoroscopy time was 3-8 minutes (mean, 5 minutes), no iatrogenic vascular injury and pelvic organ damage occurred. Postoperative X-ray films at 2 days indicated that 2 cases of vertical shift and 2 cases of mild rotation were not completely corrected. Postoperative CT examination at 3 days indicated that 2 pubic joint screws broke through the obturator bone cortex. None of the pubic ramus screws entered into the acetabulum, but a screw of superior pubic branch broke through the posterior cortical of superior pubic branch, a screw of posterior ilium column broke through the medial bone cortex of the ilium, and no clinical symptom was observed. One patient suffered from wound infection in the pubic symphysis, then healed after 2 weeks of wound drainage, the other wounds healed by first intention. According to Matta criterion for fracture reduction, the results were excellent in 9 cases, good in 4 cases, and fair in 1 case with an excellent and good rate of 92.9%. All patients were followed up 8-24 months (mean, 14 months). All fractures healed at 4 months and restored to the normal walking at 6 months after operation, 3 patients suffered from slight pain in the sacroiliac joints and slight claudication when they were tired or walked for a long time and unnecessary for special treatment. One patient felt pain in the back of the iliac spine when he was lying down. During the follow-up, no screw loosening or other internal fixation failure occurred. At last follow-up, according to Majeed functional evaluation criteria, the results were excellent in 7 cases, good in 5 cases, and fair in 2 cases with an excellent and good rate of 85.7%.ConclusionThe percutaneous cannulated screw fixation is a safe treatment for Day type Ⅱ pelvic crescent fracture, which has a reliable fixation and good effectiveness.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with double heads compressive cannulated screw fixation in adolescents

    ObjectiveTo discuss the effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture in adolescents by using double heads compressive cannulated screw fixation.MethodsTwenty-four patients with ACL tibial eminence avulsion fractures were treated by arthroscopic reduction and internal fixation with double heads compressive cannulated screw fixation between June 2014 and June 2017. There were 15 males and 9 females with an average age of 12.3 years (range, 5-18 years). The body mass index was 19.3-26.4 kg/m2 (mean, 23.3 kg/m2). The injury causes included traffic accident injury in 10 cases, sports injury in 8 cases, and falling injury in 6 cases. According to the Meyers-McKeever classification, there were 19 cases of type Ⅱ and 5 cases of type Ⅲa. All patients’ drawer test and pivot shift test were positive. The interval between injury and operation was 3-14 days (mean, 6.2 days). During the follow-up period, the fracture healing condition of patients were determined by X-ray examination; Lysholm score, International Knee literature Committee (IKDC) score, and Tegner score were used to evaluate the knee function.ResultsPrimary healing of incision was obtained in all patients after operation. All the 24 patients were followed up 6-32 months (mean, 16.4 months). At 6 weeks after operation, 3 patients had difficulty in knee flexion. After the release of the knee joint by manipulation, the knee joint function recovered normally at 6 months after operation. At last follow-up, the X-ray films showed that all the fractures healed and no epiphyseal dysplasia, knee joint deformity, or leg length discrepancy occurred. The Lysholm score, IKDC score, and Tegner score were improved from preoperative 44.3±5.4, 43.7±4.4, and 3.0±1.3 to postoperative 93.1±4.3, 94.6±3.3, and 8.1±1.2, the differences were all significant (t=25.152, P=0.000; t=28.634, P=0.000; t=13.226, P=0.000).ConclusionThe arthroscopic reduction and internal fixation with double heads compressive cannulated screw in treatment of ACL tibial avulsion fracture (Meyers-McKeever type Ⅱ and Ⅲ) in adolescents has so many advantages, such as minimal trauma, simple operation, firm fixation, little effect on the epiphyseal plate, and has a good joint function recovery.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture

    ObjectiveTo explore the changes of bone and risk of micro-fracture in femoral head after removal of cannulated screws following femoral neck fracture healing under the impact force of daily stress.MethodsA total of 42 specimens of normal hip joint were collected from 21 adult fresh cadaveric pelvic specimens. Wiberg central-edge (CE) angle, bone mineral density, diameter of femoral head, neck-shaft angle, and anteversion angle of femoral neck were measured. Then, the 3 cannulated screws were implanted according to the AO recommended method and removed to simulate the complete anatomical union of femoral neck fracture. The morphology of screw canal in the femoral head was observed by CT. Finally, the specimens were immobilized vertically within the impact device in an upside-down manner, and the femoral heads were impacted vertically. Every specimen was impacted at 200, 600, and 1 980 N for 20 times with the impacting device. After impact, every specimen was scanned by CT to observe the morphology changes of screw canal in the femoral head. Micro-fractures in the femoral head could be confirmed when there was change in the morphology of screw canal, and statistical software was used to analyze the risk factors associated with micro-fractures.ResultsAfter impact at 200 and 600 N, CT showed that the morphology of screw canal of all specimens did not change significantly compared with the original. After impact at 1 980 N, there were protrusion and narrowing in the screw canal of the 22 femoral head specimens (11 pelvic specimens), showing obvious changes compared with the original screw canal, indicating that there were micro-fractures in the femoral head. The incidence of micro-fracture was 52.38% (11/21). logistic regression results showed that there was correlation between micro-fracture and bone mineral density (P= 0.039), but no correlation was found with CE angle, diameter of femoral head, neck-shaft angle, and anteversion angle (P>0.05).ConclusionThe micro-fractures in the femoral head may occur when the femoral head is impacted by daily activities after removal of cannulated screws for femoral neck fractures, and such micro-fractures are associated with decreased bone density of the femoral head.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • Comparison of effectiveness of two cannulated screw configurations in the treatment of femoral neck fractures in young adults

    ObjectiveTo investigate and analyze the effectiveness of internal fixation with the two different cannulated screw implanting methods of rhomboid and inverted triangle in the treatment of femoral neck fracture in young adults.MethodsThe clinical data of 38 young adults with femoral neck fracture who met the selection criteria between January 2018 and August 2019 were retrospectively analyzed. According to the different methods of cannulated screw implanting, the patients were divided into two groups, 19 cases in each group. The trial group was treated with closed reduction and cannulated screw rhombic distribution internal fixation, while the control group was treated with closed reduction and cannulated screw inverted triangular distribution internal fixation. There was no significant differences in patients’ gender, age, cause of injury, Garden classification of fracture, and time from injury to operation between the two groups (P>0.05). The fracture healing time, the incidence of nonunion, femoral neck shortening, and femoral head necrosis were recorded and compared between the two groups; the effectiveness was evaluated by Harris score and visual analogue scale (VAS) score at last follow-up.ResultsThe incisions of the two groups healed by first intention. All patients were followed up 12-24 months with an average of 15.5 months. There were 1 case of fracture nonunion and 2 cases of shortening of femoral neck in the trial group; while there were 2 cases of fracture nonunion, 1 case of necrosis of femoral head, and 6 cases of femoral neck shortening in the control group; the difference in the incidence of complications (15.8% vs. 47.4%) between the two groups was significant (χ2=4.385, P=0.036). The remaining 18 cases in the trial group and 17 cases in the control group all achieved osteonal union, and the healing time was (14.8±1.6) weeks and (15.9±1.3) weeks, respectively, showing no significant difference between the two groups (t=1.265, P=0.214). At last follow-up, Harris score and VAS score of the trial group were 88.9±4.3 and 1.1±0.7, respectively, while those of the control group were 86.9±5.9 and 1.3±0.9, respectively, showing no significant difference (t=0.603, P=0.550; t=1.152, P=0.257). Hip function was evaluated in accordance with Harris score, the results were excellent in 12 cases, good in 6 cases, and fair in 1 case in the trial group, the excellent and good rate was 94.74%; the results were excellent in 10 cases, good in 7 cases, and fair in 2 cases in the control group, the excellent and good rate was 89.47%; there was no significant difference in the excellent and good rate between the two groups (χ2=0.368, P=0.544).ConclusionThe short-term effectiveness of the two kinds of cannulated screw implanting methods is clear, rhomboid fixation of 4 screws has strong stability with stress distribution, which can effectively reduce the incidence of femoral neck shortening, fracture nonunion, femoral head necrosis, and other complications.

    Release date:2021-03-26 07:36 Export PDF Favorites Scan
  • Comparison of femoral neck system and inverted triangle cannulated screws fixations in treatment of Pauwels typle Ⅲ femoral neck fractures

    ObjectiveTo compare the effectiveness of the femoral neck system (FNS) and inverted triangle cannulated screws (ITCS) for the treatment of Pauwels type Ⅲ femoral neck fractures.MethodsThe clinical data of 59 patients with Pauwels type Ⅲ femoral neck fractures treated between May 2019 and November 2020 were retrospectively analysed. The patients were divided into FNS group (28 cases) and ITCS group (31 cases) according to the different internal fixation. There was no significant difference in gender, age, affected side, body mass index, cause of injury, smoking history, alcohol abuse history, Pauwels angle, Garden classification, AO/Orthopaedic Trauma Association (AO/OTA) classification, and time from injury to operation between the two groups (P>0.05). The operation time, incision length, intraoperative blood loss, extra assisted reduction procedures (Kirschner wire prying reduction or open reduction), hospitalization stay, and early complications were recorded and compared between the two groups. Garden index and Haidukewych score were used to evaluate fracture reduction. Fracture healing time, lateral thigh irritation, time of partial or total weight-bearing postoperatively, shortening length and degree of femoral neck, change of caput-collum-diaphysis (CCD) angle (the difference of CCD angle between immediate after operation and last follow-up), incidence of osteonecrosis of femoral head and revision surgery were recorded and compared between the two groups. Hip joint function were evaluated by Harris score.ResultsThe operation time of FNS group was significantly shorter than ITCS group, and the incision length was significantly longer than ITCS group (P<0.05). There was no significant difference in intraoperative blood loss, assisted reduction, Garden index, Haidukewych score, and hospitalization stay between the two groups (P>0.05). All the incisions healed by first intention. There were 2 deep vein thrombosis in the FNS group and 1 pulmonary infection and 1 deep vein thrombosis in the ITCS group. No significant difference was found in the incidence of early postoperative complications (7.1% vs. 6.5%) between the two groups (P=1.000). Patients in both groups were followed up 3-14 months, and there was no significant difference in follow-up time between the two groups (t=–0.553, P=0.582). The fracture healing time, Harris score, and the partial weight-bearing time after operation of the FNS group were significantly better than those of the ITCS group (P<0.05). However, there was no significant difference in total weight-bearing time between the two groups (Z=–1.298, P=0.194). No lateral thigh irritation was found in the FNS group, while 10 patients in the ITCS group had lateral thigh irritation, and the incidence between the two groups (0 vs. 32.3%) was significant (P=0.001). At last follow-up, the shortening length and degree of femoral neck and the change of CCD angle in FNS group were significantly less than those in ITCS group (P<0.05). There was no patient with osteonecrosis of femoral head or reoperation in the FNS group, while 4 patients in the ITCS group underwent reoperation (including 2 cases of osteonecrosis of the femoral head). However, the incidences (0 vs. 6.5%; 0 vs. 12.9%) between the two groups were not significant (P=0.493; P=0.114).ConclusionUsing FNS to treat Pauwels type Ⅲ femoral neck fracture is simple as well as able to reduce the shortening of the femoral neck and the change of the CCD angle. Also, FNS is conducive to the recovery of hip joint function, which should be considered as a new choice for the treatment of young femoral neck fracture patients.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format