west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "cone beam computed tomography" 4 results
  • Imaging analysis of jaw defects reparation with antigen-extracted porcine cancellous bone

    At present, most of the bone xenograft for clinical application comes from bovine. In recent years, many studies have been done on the clinical application of porcine xenograft bone. The goal of this study was to evaluate the effect of canine mandibular defects reparation with antigen-extracted porcine cancellous bone by imaging examination. Four dogs’ bilateral mandibular defects were created, with one side repaired with autologous bone (set as control group) while the other side repaired with antigen-extracted porcine cancellous bone (set as experimental group). Titanium plates and titanium screws were used for fixation. Cone beam computed tomography (CBCT), computed tomography (CT), single-photon emission computed tomography (SPECT) were undertaken at week 12 and 24 postoperatively, and SPECT and CT images were fused. The results demonstrated that the remodeling of antigen-extracted porcine cancellous bone was slower than that of autologous bone, but it can still be used as scaffold for jaw defects. The results in this study provide a new choice for materials required for clinical reparation of jaw defects.

    Release date:2017-12-21 05:21 Export PDF Favorites Scan
  • A tooth cone beam computer tomography image segmentation method based on the local Gaussian distribution fitting

    Oral teeth image segmentation plays an important role in teeth orthodontic surgery and implant surgery. As the tooth roots are often surrounded by the alveolar, the molar’s structure is complex and the inner pulp chamber usually exists in tooth, it is easy to over-segment or lead to inner edges in teeth segmentation process. In order to further improve the segmentation accuracy, a segmentation algorithm based on local Gaussian distribution fitting and edge detection is proposed to solve the above problems. This algorithm combines the local pixels’ variance and mean values, which improves the algorithm’s robustness by incorporating the gradient information. In the experiment, the root is segmented precisely in cone beam computed tomography (CBCT) teeth images. Segmentation results by the proposed algorithm are then compared with the classical algorithms’ results. The comparison results show that the proposed method can distinguish the root and alveolar around the root. In addition, the split molars can be segmented accurately and there are no inner contours around the pulp chamber.

    Release date:2019-04-15 05:31 Export PDF Favorites Scan
  • Precision TACE assisted by radial artery approach and CBCT three-dimensional vascular reconstruction in the treatment of primary liver cancer: report of 124 cases

    Objective To investigate the safety and feasibility of transcatheter arterial chemoembolization (TACE) assisted by transradial approach and cone beam computed tomography (CBCT) three-dimensional vascular reconstruction in the treatment of primary liver cancer. Methods The clinical data of 124 patients with primary liver cancer who underwent precision TACE via radial artery in our hospital from May 2018 to December 2019 were retrospectively collected. Results Among the 124 patients, 118 patients were successfully punctured through the left radial artery and completed the TACE operation. The operation time was (109.57±31.32) min, and the median of postoperative hospitalization was 3 d. One patient changed to the right radial artery to complete TACE due to chronic renal failure and left brachial artery and vein puncture and catheterization before operation. The operation time was 119 minutes, and the patient was discharged after 5 days of hospitalization. After successful puncture of the left radial artery in one patient, the forearm artery was twisted into a loop and the guide wire catheter failed to pass, and the right femoral artery was used to complete TACE. The operation time was 123 minutes, and the patient was discharged after 4 days of improvement. The radial artery puncture was unsuccessful in four patients, and the right femoral artery approach was used to complete the operation; the operation time was (111.66±32.77) min, and the median of postoperative hospitalization was 3 d. One of the patients successfully completed up to 5 consecutive TACE via the radial artery. All patients underwent precision TACE with superselective cannulation assisted by CBCT three-dimensional vascular reconstruction. No vascular injury andocclusion, urinary retention, subcutaneous hemorrhage, and other complications occurred in all patients. Conclusions Trans-radial arterial precision TACE is safe and effective, which can be repeated many times and has few complications and high patient comfort. It can be used as one of the routine approaches of TACE.

    Release date: Export PDF Favorites Scan
  • A retrospective study to evaluate the efficacy and safety of CT-guided percutaneous and cone beam CT-guided transbronchial ablation for multiple primary lung cancer

    Objective To evaluate the efficacy and safety of computed tomography (CT)-guided percutaneous and cone beam CT-guided transbronchial ablation in the treatment of early multiple primary lung cancer (MPLC). Methods Retrospective analysis was performed on patients who met inclusion criteria in Shanghai Chest Hospital between May 2020 to June 2022. According to ablation pathway, lesions were divided into two groups: percutaneous ablation group and transbronchial ablation group. Results A total of 13 MPLC patients with 26 lesions were included (14 percutaneous ablation and 12 transbronchial ablation). There were no statistically significant differences in solid component, lesion location, lung field and lesion size between the two groups. The distance from the parietal pleura in the transbronchial ablation group was longer than that in percutaneous ablation group (P=0.03). The median follow-up period time were 13 months and 12 months for group percutaneous ablation and transbronchial ablation. No significant differences were found in 3-month complete ablation rate (100.0% vs. 83.3%), 1-year local control rate (100.0% vs. 91.7%) and severe complication rate (7.1% vs. 16.7%). The minor complication rate in percutaneous ablation group was higher than that in transbronchial ablation group (50.0% vs 0.0%, P=0.02). Conclusions Percutaneous ablation and transbronchial ablation have high efficacy and safety, and the latter involves lower minor complication rate. They complement each other, which provide the individualized treatments for early MPLC patients who are not suitable for or refuse surgery.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content