west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "disinfection" 13 results
  • Investigation and Analysis on Prophlactical Disinfection in Deyang Disaster Areas after Wenchuan Earthquake

    Objective To provide the evidence for anti-epidemic command and developing response plan through investigation on prophlactical disinfection in Deyang, the worst-hit areas after Wenchuan earthquake. Methods We used convenient sampling together with the report forms and the self-made questionnaire to collect information from 107 villages and 17 settlement spots for the disaster victims in 25 towns in Deyang disaster area. Results There were a total of 6 kinds of disinfectant, including the chlorine disinfectant, 2 kinds of peroxide disinfectant and 2 other types of disinfectant, which were delivered the Deyang disaster area through the National amp; Province CDC system allocation or the None-Goverment Organization donation. From May 17 to June 9, the large-scale preventive disinfection was carried out in the disaster area, covering tap water, the restroom and the latrine pit, trash, environment and sewage. All personnel who conducted the disinfection for prevention and public health in the villages and towns received the technical training for disinfection. Conclusion Various disinfectant types and difference specifications cause trouble in the training of manpower and the use of disinfectant. Preventive disinfection in the most serious disaster areas is better than in serious disaster areas. The main channel of obtaining the disinfectant is through the National amp; Province CDC. The daily-report system of the disinfected areas may monitor the progress of disinfectant use. The suitable disinfection may prevent the public health secondary disaster and protect the environment effectively.

    Release date:2016-09-07 02:13 Export PDF Favorites Scan
  • Investigation and Analysis on the Standardization of Surgical Hand-washing and Hand-disinfection

    ObjectiveTo investigate on preoperative hand-washing for analyzing the underlying problems, in purpose of preventing operation-related infection via strengthening the standardization of surgical hand-washing and hand-disinfection. MethodsFrom July to September 2014, surveillance video of pre-operative hand-washing was studied and analyzed. We randomly selected 100 subjects, and assessment was performed based on the self-made surgical hand-washing and hand-disinfection protocol. Grading was done strictly. The passing score was 60 or higher; a score of 70-79 meant good; and a score of 80-100 indicated excellence. ResultsIn the survey, 91 in the 100 subjects were qualified. Among the qualified subjects, there were 53% of excellence and 20% of good. The major problems included erroneous methods, step omissions, time lacking, pollution, wrong flushing method or dry-hand method, and insufficient washing time. ConclusionBased on the survey, the administration department is advised to strengthen the regulatory supervision and education training based on standard surgical hand-washing and hand-disinfection criteria, especially training interns and new staff, in purpose of reducing the incidence of operation-related infection and improving hospitalization management qualities.

    Release date: Export PDF Favorites Scan
  • Experimental study on silicone hand disinfection by a touchable non-thermal plasma

    In this study, silicone hand was disinfected by homemade touchable non-thermal plasma to simulate and evaluate its feasibility of application on human hand. Experimental results showed that there was no significant difference whenEscherichia coli (E. coli),Staphylococcus aureus (S. au),Staphylococcus albus (S. al), andPseudomonas aeruginosa (P. ae) were loaded on the silicone hand surface and treated with plasma. The efficiency of plasma disinfection was higher when the treatment time was prolonged or initial bacterial density was lower. When initial bacterial number was 1.0×106–1.0×107 CFU, the plasma disinfection process mainly occured in the first 5 s and more than 99% of bacteria could be disinfected. This study can provide guidelines for the development of a new plasma device for human hand disinfection.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • Disinfection effect of alcohol-based hand disinfectants for glove surface

    Objective To evaluate the disinfection efficacy of alcohol-based hand disinfectants for medical glove surface in continuous operation, and explore approaches of improving hand hygiene compliance. Methods Between March and July 2015, and between March and July 2016, all the nurses (n=5) in Blood Collection Room of Outpatient Department with many patients and frequent sterile operation needed were included in this study. Nurses wearing gloves for hand hygiene and disinfection between March and July 2016 were regarded as the observation group, and those who used alcohol-based disinfectants for routine hand hygiene without gloves between March and July 2015 were designated into the control group. The hand hygiene compliance was compared between the two groups. From March to July 2016, alcohol-based hand disinfectants were used for disinfection on the glove surface during continuous blood sampling by nurses with gloves on their hands. Fifty samples were collected respectively after the gloves were used for 1, 2, 5, 10, and 15 continuous times for blood sampling. Then, the samples were sent to the bacteriology room for culture. Results All of the 250 samples were qualified, and the bacterial colonies on the surface of gloves were equal to 10 cfu/mL2 or lower. NoStaphylococcus aureus,Escherichiacoli or other pathogens were detected on the glove surface. However, after the gloves were continuously used for 15 times, the gloves of two nurses could not meet the research criteria again because of significant sweating. Conclusions In the process of continuous blood sampling, it is effective to use alcohol-based hand disinfectants to disinfect the surface of medical gloves, which can promote hand hygiene compliance to a certain extent. However, there is a certain limit on the times of usage for medical gloves.

    Release date:2017-03-27 11:42 Export PDF Favorites Scan
  • Comparative study among three methods on surface disinfection in Intensive Care Unit

    Objective To compare germicidal effect of three disinfectants acting on frequently-touched surfaces in Intensive Care Unit (ICU) at different time points after disinfection so as to put forward the reasonable disinfection method and interval before the next disinfection. Methods We wiped the four frequently-touched surfaces in ICU with disinfectant containing acidic electrolyzed oxidizing water (EOW) from the building system of hospital, disinfectant wipes, and 500 mg/L chlorine respectively. The culture samples were collected from the surfaces before wiping, and 10 minutes, 30 minutes, 1 hour, 2 hours and 4 hours after wiping respectively. The bacterial clearance rate and the qualified rate of bacterial colony counts on the surfaces were compared among the three different disinfectants at different time points after disinfection. Results The bacterial killing rate of three methods for disinfection of object surfaces decreased with the passing of time. The bacterial killing rate of EOW from the building system of hospital was lower than that of the other two methods at all five time points after disinfection (P< 0.05). The bacterial killing rate at hour four after disinfection using chlorine-containing disinfectant and disinfectant wipes was higher than 90.0%. The qualified rate of bacterial colony counts on the surfaces at 10 and 30 minutes after disinfection among the three groups was not significantly different (P>0.05). The qualified rate of bacterial colony counts on the surfaces disinfected by EOW from the building system of hospital was lower than that in the other two groups at the other three time points (P<0.05), and it was totally unqualified at hour four after disinfection. Conclusions The germicidal effect of EOW from the building system of hospital is inferior to chlorine disinfectant and disinfectant wipes. Moreover, the surface can be easily recontaminated after disinfection. It is suggested that EOW should be used in ICU every other hour. and the other two disinfection methods should be used every two hours.

    Release date:2017-03-27 11:42 Export PDF Favorites Scan
  • Innovative practice of auditing qualification documents of disinfectant, disinfection devices and disposable medical devices

    The quality of disinfectant, disinfection devices and disposable medical devices is closely related to the patients' safety. Hospital infection management department must carry out the audit responsibilities for qualification documents of disinfectant, disinfection devices and disposable medical devices, to guarantee legality, safety and effectiveness of products used in hospital. This paper mainly introduces the implementation of qualification documents audit in West China Hospital, Sichuan University, including system construction, process reengineering, documents audit scope and key points, and document management.

    Release date:2018-03-26 03:32 Export PDF Favorites Scan
  • Disinfection effect and cost analysis of three different sanitary hand disinfection methods

    ObjectiveTo explore a better hygienic hand disinfection method to improve hand hygiene compliance, by evaluating and comparing the disinfection effects and the economic and time cost expenditures of three different types of hygienic hand disinfection methods.MethodsFrom March to July 2016, patients undergoing blood collection were randomly divided into three groups, and five blood collection nurses used one different type of hygienic hand disinfection method in each group when performing blood collection operation on the patients, including: direct hygienic hand disinfection (group A); wearing gloves, and doing hygienic hand disinfection without putting off gloves (group B); and changing gloves for each patient, and doing hygienic hand disinfection after putting off gloves (group C). Two hundred and ten specimens of the nurses’ hands or gloves surface after hand hygiene were collected from each group for the comparison of hygienic hand disinfection effect, and the differences in economic cost and time cost were compared.ResultsThe passing rates of the disinfection effect of the three different types of sanitary hand disinfection methods were all 100%. The economic cost of group A, B, and C was 9.66, 21.98, and 185.66 yuan, respectively, and the time cost of group A, B, and C was 5 250, 6 860, and 14 700 seconds, respectively. No sharp injury occurred.ConclusionSince direct hygienic hand disinfection does not implement the standard prevention principle, the method of wearing gloves and doing hygienic hand disinfection without putting off gloves is the best in the three different hygienic hand disinfection methods, which not only has the same disinfection effect, but also can save economic cost and time cost, which may improve the medical personnel’s hand hygiene compliance.

    Release date:2019-03-22 04:19 Export PDF Favorites Scan
  • Research on coronavirus disease 2019 field disinfection technology for prevention and control

    The coronavirus disease 2019 (COVID-19) epidemic has had a serious impact in the world. In the absence of vaccines and therapeutic drugs, disinfection has become an important technical means to block the spread of the virus. By analyzing the characteristics of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), we studied a series of disinfection technologies for COVID-19. During the outbreak of COVID-19, Jinan Second Center for Disease Control and Prevention disinfected the houses of the cases to be investigated in a community. The effectiveness of the disinfection technology was verified through the process of disinfection preparation, sampling before disinfection, field disinfection, sampling after disinfection and evaluation of disinfection effect. Compared the data before and after disinfection, the killing rate of the total bacterial colonies in the air and on the surface of the object was more than or equal to 90%, and no SARS-CoV-2 was detected after disinfection. The results show that the disinfection effect of the disinfection technology meets the standard. Finally, through the analysis of the wrong way of disinfection and the harm of over disinfection, the importance of scientific disinfection and precise disinfection are emphasized, and the research has a good guiding value for prevention and control of the epidemic.

    Release date:2020-10-20 05:56 Export PDF Favorites Scan
  • Analysis of high-level disinfection effect of flexible endoscopes in an endoscope center

    ObjectiveTo evaluate the high-level disinfection effect of flexible endoscopes in the Endoscopy Center of the First People’s Hospital of Longquanyi District of Chengdu, explore the key links of flexible endoscope cleaning and disinfection, and provide theoretical guarantee and technical support for the next step of the endoscope center work.MethodsWe sampled and monitored the lumens, water and air injection ports and biopsy ports of 19 flexible endoscopes after high-level disinfection in the Endoscopy Center of the First People’s Hospital of Longquanyi District of Chengdu. A total of 307 specimens were collected from 108 flexible endoscopes. We compared the disinfection effects of different flexible endoscopes and different sampling sites, and compared the microbial detection status of different flexible endoscopes.ResultsThe qualified rates of disinfection of gastroscopes, colonoscope and duodenoscopy were 79.22%, 86.21% and 100.00%, respectively, and the difference was not statistically significant (P=0.721). The qualified rates of disinfection of the endoscopic lumen, water and air injection port and biopsy port were 87.04%, 93.00% and 94.95%, respectively, and the difference was not statistically significant (χ2=4.585, P=0.101). The qualified rates of the lumen, water and air injection port and biopsy port of gastroscope, colonoscope and duodenoscope were 84.42%, 93.10%, 100.00%, 92.96%, 92.59%, 100.00%, 94.29%, 96.30%, 100.00%, respectively. There was no statistically significant difference in the disinfection effect of various parts of different flexible endoscopes (P>0.05). Bacteriological identification showed that of the 28 specimens with excess bacteriological standards, 16 gram-positive bacteria (57.1%), and 12 gram-negative bacteria (42.9%) were found.ConclusionThe cleaning and disinfection effect of flexible endoscopes has certain defect. Endoscope should be treated in strict accordance with the technical specifications for cleaning and disinfection of the flexible endoscope to further improve the disinfection effect of the flexible endoscope.

    Release date:2021-04-15 05:32 Export PDF Favorites Scan
  • Efficiency of hydrogen peroxide vapors in reducing multidrug-resistant organisms: a meta-analysis

    ObjectiveTo evaluate the efficiency of hydrogen peroxide vapor (HPV) in disinfecting multidrug-resistant organisms (MDROs).MethodsWe searched Cochrane Library, PubMed, Embase, Web of Science, China National Knowledge Infrastructure, Wanfang, China Science and Technology Journal Database for before-after studies or case-control studies or cohort studies evaluating efficiency of HPV and published from January 2010 to December 2020 (the time range was from January 2000 to December 2020 in the snowball searching). RevMan 5.4 and R 4.0.2 softwares were used for meta-analysis.ResultsA total of 9 studies were included, consisting of 8 before-after studies and 1 cohort study. Six studies evaluated positive rate of environmental samplings, meta-analysis revealed that HPV combined with manual cleaning disinfected the environment efficiently [relative risk (RR)=0.03, 95% confidence interval (CI) (0.01, 0.08), P< 0.000 01] and HPV was more efficient than manual cleaning [RR=0.04, 95%CI (0.02, 0.10), P< 0.000 01]. Three studies evaluated the hospital-acquired MDROs colonization/infection rates, and the results of the 3 studies were consistent, revealing that HPV could reduce hospital-acquired MDROs colonization/infection rates.ConclusionHPV is efficient in reducing MDROs contaminated surfaces and hospital-acquired infection rate.

    Release date:2021-04-15 05:32 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content