west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "fixation technique" 5 results
  • Effectiveness of F-shaped screw fixation technique in treatment of Pauwels type Ⅲ femoral neck fractures

    Objective To summarize the effectiveness of F-shaped screw fixation technique in treatment of Pauwels type Ⅲ femoral neck fractures. Methods Between January 2013 and December 2016, 43 patients with Pauwels type Ⅲ femoral neck fractures were treated with F-shaped screw fixation technique. There were 32 males and 11 females with an average age of 38.9 years (range, 20-55 years). The fractures located on the left side in 21 patients and on the right side in 22 patients. The cause of injury included traffic accident in 19 patients and falling from height in 24 patients. There were 25 patients of Garden type Ⅲ and 18 of Garden type Ⅳ. The time from injury to operation was 2-3 days (mean, 2.2 days). These data were recorded, including operative time, fluoroscopy time, postoperative hospital stay, quality of reduction, postoperative complications (nonunion, varus deformity, femoral neck shortening, avascular necrosis of femoral head, screws back-out), and Harris scores. Results The operative time was 28-45 minutes (mean, 37.5 minutes). The fluoroscopy time was 13-20 seconds (mean, 14.7 seconds). The postoperative hospital stay was 2-3 days (mean, 2.7 days). All incisions healed by first intention. All patients were followed up 18–58 months with an average of 38.7 months. All patients have anatomical reduction of fractures. Fracture healing occurred in 42 patients; the union time was 3-5 months with an average of 3.6 months. Nonunion occurred in 1 patient who was treated with total hip arthroplasty. Of the 42 patients with fracture healing, 11 cases had a femoral neck shortening, 9 cases had varus deformity, 3 cases had avascular necrosis of femoral head, and 8 cases had screws back-out. There was no significant difference in complication incidences between Garden type Ⅲ fractures and Garden type Ⅳ fractures (P>0.05). Conclusion Treatment of femoral neck fractures by using the F-shaped screw fixation technique, can achieve satisfactory effectiveness with less postoperative complication.

    Release date:2018-10-31 09:22 Export PDF Favorites Scan
  • Ilizarov external fixation without bone graft for atrophic femoral shaft nonunion

    Objective To explore the effectiveness of Ilizarov external fixation without bone graft in the treatment of atrophic femoral shaft nonunion. Methods The clinical data of 12 patients with atrophic femoral shaft nonunion admitted between October 2010 and January 2017 were retrospectively analyzed. There were 8 males and 4 females, aged from 24 to 61 years, with an average age of 41.7 years. The nonunion sites located in the middle and upper femur in 7 cases and in the distal femur or supracondylar in 5 cases. The disease duration ranged from 1 to 9 years, with an average of 3.7 years. Previous operations ranged from 1 to 9 times, with an average of 2.8 times. The original fixator was removed, the fracture end of nonunion was debrided, and Ilizarov external fixator was installed. In patients with the length of bone defect less than 4 cm, direct compression fixation was performed during operation; in patients with limb shortening more than 2.5 cm, proximal femoral osteotomy and bone lengthening components were required to prepare limb lengthening after operation; all patients did not receive bone graft. The wearing time of external fixator, clinical bone healing time of nonunion fracture end, and complications were recorded. The effectiveness was evaluated by Paley’s nonunion evaluation criteria. Results All patients were followed up 24-50 months, with an average of 30 months. Bony union was achieved in all 12 cases with a healing time of 6.0-23.5 months (mean, 11.5 months). The wearing time of external fixator ranged from 7 to 25 months, with an average of 13.5 months. At last follow-up, according to Paley’s nonunion evaluation criteria, the results were excellent in 6 cases, good in 4 cases, and fair in 2 cases, with an excellent and good rate of 83.3%. Sagittal angulation deformity of femur more than 7° occurred in 4 cases, with no significant effect on knee extension function, and no special treatment such as osteotomy was performed. Two patients had shorter limbs (>2.5 cm) after operation and were replaced by high shoes; 4 patients with trans-knee fixation lost knee joint mobility of 10-30° after operation; 10 cases of needle tract infection occurred, of which 4 cases with infection and loosening of fixed needle were replaced and re-fixed after needle extraction, the remaining 6 cases of infection without loosening of fixed needle were controlled by local dressing change, needle nursing, and oral cephalosporin anti-inflammatory drugs. No complications such as deep infection and vascular nerve injury occurred. Conclusion Ilizarov external fixation has a high healing rate for atrophic femoral shaft nonunion, which is relatively minimally invasive and can avoid bone grafting. Its preliminary effectiveness is exact, and it is also effective for patients who have experienced multiple failed operations. It is necessary to pay attention to the nursing and rehabilitation training after external fixation.

    Release date:2019-07-23 09:50 Export PDF Favorites Scan
  • Application of suspensory external fixation technique in treatment of proximal humeral fracture

    ObjectiveTo investigate the effectiveness of suspensory external fixation technique in treatment of proximal humeral fractures.MethodsBetween August 2013 and October 2018, 14 patients with proximal humeral fractures were treated with suspensory external fixation technique. There were 10 males and 4 females with an average age of 55.9 years (range, 43-76 years). There were 10 cases of falling injury and 4 cases of traffic accident injury. Among them, there were 9 cases of Neer type Ⅲ and 5 cases of Neer type Ⅳ. The time from injury to operation was 3-7 days (mean, 4.6 days). Nine cases were complicated with osteoporosis. The preoperative visual analogue scale (VAS) score was 6.1±1.2. The effectiveness was comprehensively evaluated by hospital stay, fracture healing time, removal time of external fixator, postoperative complications, VAS score, and Neer score of shoulder joint function.ResultsAll operations were successfully completed, and the hospital stay was 6-14 days, with an average of 9.4 days. All the incisions healed by first intention, and no infection or other complications occurred. All patients were followed up 16-60 months (mean, 35.4 months). X-ray films examination showed that all fractures healed, the healing time was 4-7 months (mean, 4.9 months). The removal time of external fixator was 5-8 months (mean, 6.3 months). VAS scores were 1.5±0.8 at 1 month after operation and 1.0±0.9 at last follow-up, both of which were significantly improved when compared with preoperative score, the differences were significant between different time points (P<0.05). Neer score of shoulder joint function was 75-100 (mean, 91.1); 9 cases were excellent, 4 cases were good, and 1 case was fair. The excellent and good rate was 92.9%. During follow-up, there was no adverse events such as acromion impingement, nonunion, or pseudoarthrosis.ConclusionFor proximal humeral fractures, the suspensory external fixation technique is a simple and reliable treatment method that can significantly improve joint function.

    Release date:2021-02-24 05:33 Export PDF Favorites Scan
  • Treatment of unstable fresh thoracolumbar burst fracture by over-bending rod reduction and fixation technique via posterior approach

    ObjectiveTo investigate the efficacy and safety of over-bending rod reduction and fixation technique via posterior approach in the treatment of unstable fresh thoracolumbar burst fracture.MethodsA clinical data of 27 patients with unstable fresh thoracolumbar burst fracture, who were met the inclusive criteria and admitted between January 2018 and October 2019, was retrospectively analyzed. There were 15 males and 12 females with an average age of 41.8 years (range, 26-64 years). The fractures were caused by falling from height in 14 cases, traffic accident in 8 cases, and crushing by a heavy objective in 5 cases. The interval between injury and operation was 1-7 days (mean, 3.2 days). The injured fracture was located at T10 in 1 case, T11 in 3 cases, T12 in 6 cases, L1 in 7 cases, L2 in 7 cases, and L3 in 3 cases. According to AO classification, there were 11 cases of type A3, 7 cases of type B, and 9 cases of type C. Neurological function was rated as grade A in 3 cases, grade B in 7 cases, grade C in 5 cases, and grade D in 12 cases according to the American Spinal Injury Association (ASIA) grading. All cases were treated by over-bending rod reduction and fixation technique via posterior approach, and 16 cases were combined with limited fenestration decompression. The evaluation indicators consisted of operation time, intraoperative blood loss, the compression ratio of the anterior vertebral height, the invasion rate of the injured vertebra into the spinal canal, the Cobb angle of segmental kyphosis, visual analogue scale (VAS) score, and Oswestry Disability Index (ODI).ResultsThe operation time was 67-128 minutes (mean, 81.6 minutes), and the intraoperative blood loss was 105-295 mL (mean, 210 mL). All patients were followed up 12-23 months (mean, 17.2 months). A total of 178 pedicle screws were implanted during operation, and the accuracy of the implantation was 98.9% (176/178). The compression ratios of the anterior vertebral height at the early postoperatively and last follow-up were significantly increased when compared with preoperative one (P<0.05), and the invasion rate of the injured vertebra into the spinal canal, Cobb angle, VAS score, and ODI were significantly lower than those preoperatively (P<0.05). Except that the ODI at last follow-up was significantly lower than that of the early postoperative period (P<0.05), there was no significant difference between the last follow-up and the early postoperative period for other indicators (P>0.05). At last follow-up, the neurological function was rated as grade A in 1 case, grade B in 2 cases, grade C in 4 cases, grade D in 9 cases, and grade E in 11 cases according to the ASIA grading, showing significant difference when compared with that before operation (Z=–3.446, P=0.001).ConclusionOver-bending rod reduction and fixation technique can effectively restore vertebral height, reset the invaded vertebral block, and selectively perform limited decompression and posterolateral bone grafting to ensure the completeness of intravertebral decompression and stability, which is one of the effective methods to treat unstable fresh thoracolumbar burst vertebral fracture.

    Release date:2021-04-27 09:12 Export PDF Favorites Scan
  • Comparative study of transosseous suture and suture anchor technique in medial patellofemoral ligament double bundle reconstruction

    Objective To investigate the effectiveness of transosseous suture in medial patellofemoral ligament (MPFL) double bundle reconstruction. Methods The clinical data of 75 patients with recurrent patella dislocation who met the selection criteria between January 2014 and December 2017 were retrospectively analyzed. All of them were treated with MPFL double bundle reconstruction, and divided into study group (39 cases, using new transosseous suture technique) and control group (36 cases, using traditional suture anchor fixation) depending on the intraoperative fixation technique. There was no significant difference in gender, age, body mass index, affected knee side, preoperative tibial tuberosity-trochlear groove distance, Insall-Salvati ratio, knee range of motion, Kujala score, International Knee Documentation Committee (IKDC) score, congruence angle, and tilt angle between the two groups (P>0.05). The operation time, intraoperative blood loss, hospital stay, and postoperative complications were recorded and compared between the two groups. Kujala score, IKDC score, and knee range of motion were used to evaluate the functional improvement of patients before and after operation. The congruence angle and tilt angle were measured on X-ray films. Results There was no significant difference in operation time, intraoperative blood loss, and hospital stay between the two groups (P>0.05). Patients in both groups were followed up 24-36 months, with an average of 29.4 months. There was no complication such as incision infection, fat liquefaction, patellar redislocation, and prepatellar pain during follow-up. At last follow-up, the Kujala score, IKDC score, knee range of motion, congruence angle, and tilt angle of two groups significantly improved when compared with those before operation (P<0.05), while there was no significant difference between the two groups (P>0.05). ConclusionThe application of suture anchor or transosseous suture to complete MPFL double bundle reconstruction can restore patellar stability, and there is no significant difference in the short-term effectiveness between them.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content