west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "fluorescence imaging" 9 results
  • The clinical application and progress of indocyanine green-fluorescence imaging in liver tumor surgery

    Objective To summarize the application and progress of the indocyanine green-fluorescence imaging in liver tumor surgery, at the same time, to demonstrate the advantages, limitations, and prospects of this technology. Methods Clinical researches about indocyanine green-fluorescence imaging in liver tumor surgery were collected, to review the introduction and principle of indocyanine green-fluorescence imaginging, and its clinical application of detecting small lesions and demarcating boundaries in liver tumor surgery. Results Indocyanine green-fluorescence imaging had been used in liver tumors surgery. In the aspect of locating the tumors, detecting small lesions, and demarcating boundaries, it had begun to show its unique value. And it was provided to be a new way to reduce tumor recurrence, improve treatment effect, and prolong survival time. Conclusions Indocyanine green-fluorescence imaging is now in the stage of development and promotion, and it has great development potential in technology. But, it also needs advancement in identification ability of benign and malignant lesions, and the depth of detection.

    Release date:2018-08-15 01:54 Export PDF Favorites Scan
  • Effect of DDX46 gene on the growth of xenografted tumor of esophageal squamous cell carcinoma in nude mice

    Objective To observe the growth of xenografted tumor in nude mice after DDX46 expression decreased, and to further study the role of DDX46 in the development and progression of esophageal squamous cell carcinoma. Methods DDX46-shRNA mediated RNAi was applied to silencing DDX46 in Eca-109 cells. Twenty-five female BALB/c nude mice were divided into 3 groups: an experiment group (DDX46-shRNA-LV, n=10), a control group (Control-LV, n=10) and a blank control group (Het-1A, n=5). The prepared Eca-109 cells of DDX46-shRNA-LV and Control-LV were subcutaneously injected into the right armpit of mice (4×106 cells per mouse), while Het-1A cells were subcutaneously injected into the bilateral armpits of mice (4×106 cells per side). Tumor growth was monitored twice a week on the 14th day after injection. Tumor volume was measured with calipers, in vivo imager to observe the fluorescence of each group. Further, western blotting analysis was used to detect the changes of apoptosis signaling molecules in xenografted tumor after DDX46 silence. Results The growth of xenografted tumor in nude mice was significantly slower in the DDX46-shRNA-LV group than that in the Control-LV group throughout the study period (P<0.001). Western blotting analysis showed that silencing DDX46 effectively suppressed the expression of DDX46, and upregulated the expression of cleaved Caspase-3 and cleaved PARP-1 in xenografted tumor (P<0.01). Conclusion DDX46 is involved in the development and progression of esophageal squamous cell carcinoma, and the silence of DDX46 expression can inhibit the growth of esophageal squamous cell carcinoma, which probably by positive regulation of apoptosis signaling pathway.

    Release date:2019-01-23 02:58 Export PDF Favorites Scan
  • Laparoscopic Glissonean pedicle transection anatomic hepatectomy using indocyanine green fluorescence imaging technology

    ObjectiveTo evaluate efficacy and safety of laparoscopic Glissonean pedicle transection anatomic hepatectomy using indocyanine green (ICG) fluorescence imaging.MethodThe retrospective analysis was made on the preoperative clinical data, surgical treatment and postoperative status of a patient with hepatocellular carcinoma who underwent the laparoscopic Glissonean pedicle transection anatomic hepatectomy using the ICG fluorescence imaging technology in the Department of Liver Surgery, West China Hospital of Sichuan University.ResultsAccording to the preoperative history, imaging and laboratory examinations, the diagnosis of hepatocellular carcinoma was considered. The intraoperative exploration revealed that there was only one tumor located in the segment Ⅳ and was superficial. The ICG fluorescence imaging was used to perform the Glissonean pedicle transection anatomic hepatectomy. The postoperative pathological diagnosis was consistent with hepatocellular carcinoma without serious complications. The patient recovered well. No recurrence was found in the follow-up period up to 6 months.ConclusionsLaparoscopic Glissonean pedicle transection anatomic hepatectomy using ICG fluorescence technology can be used as a safe and precise treatment to solve problems such as bleeding during operation, difficult determination of tumor boundary, and whether having residual tumor in surgical margin.

    Release date:2019-05-08 05:37 Export PDF Favorites Scan
  • Application of indocyanine green fluorescence imaging in determining blood supply of parathyroid glands during thyroid surgery

    ObjectiveTo investigate the application value of indocyanine green (ICG) fluorescence imaging technology for determining the blood supply of parathyroid in thyroid surgery.MethodsThe patients who underwent total thyroidectomy and bilateral central lymph node dissection for papillary thyroid carcinoma (PTC) from June 1, 2017 to January 1, 2018 were prospectively enrolled and then divided into a study group and control group randomly. The study group used the ICG fluorescence imaging technology to evaluate the blood supply of the parathyroid glands, while the control group assessed the blood supply by naked eyes, then determined that whether the parathyroid glands were retained in situ or autotransplanted. The incidence of hypoparathyroidism, length of hospital stay, and parathyroid hormone (PTH) were compared between the two groups.Results① A total of 60 patients with PTC were included in the study, and 30 patients in each group. There were no significant differences in the baseline informations of the two groups such as the gender, age, comorbidities, and preoperative PTH, Ca2+ levels, etc. (P>0.05). ② The ICG score of type A parathyroid glands (except type A3) was lower than that of type B parathyroid glands (0.99±0.38 versus 1.45±0.58, t=–2.395, P<0.05). ③ The length of postoperative hospital stay was shorter in the study group than in the control group (t=–2.159, P=0.035). ④ The ICG fluorescence imaging could significantly reduce the incidence of temporary hypoparathyroidism (χ2=5.079, P=0.024). The incidence of permanent hypoparathyroidism was not statistically different between the two groups (χ2=1.000, P=0.317), and only 1 case appeared in the control group. ⑤ There were no statistically significant differences in the PTH and serum Ca2+ levels at day 1, month 1, month 3, and month 6 after the surgery between the two groups (P>0.05). ConclusionICG fluorescence imaging technology could be used to determine blood supply of parathyroid in situ in real time during operation. Further studies are needed to confirm this conclusion.

    Release date:2020-09-23 05:27 Export PDF Favorites Scan
  • Application progress of indocyanine green fluorescence imaging in laparoscopic anatomical liver resection

    ObjectiveTo summarize the application status and progress of indocyanine green fluorescence imaging in laparoscopic anatomic liver resection , and to analyze its advantages, limitations, and prospects.MethodThe literatures about indocyanine green fluorescence imaging in laparoscopic anatomic liver resection were reviewed.ResultsIndocyanine green fluorescence imaging had been preliminarily used in the operation of liver tumors and had shown its unique value in the anatomical liver resection, providing a new way to reduce the recurrence of liver cancer, improve the therapeutic effect, and prolong the survival time of patients.ConclusionsThe clinical application of indocyanine green fluorescence imaging in anatomic liver resection is still at the stage of development and popularization. Although it has unique advantages and development potential, it needs to be further improved in the aspects of tissue penetration, specificity, and staining success rate.

    Release date: Export PDF Favorites Scan
  • Application of near infra-red fluorescence imaging in biliary surgery

    ObjectiveTo summarize the research progress of near infra-red fluorescence imaging (NIRFI) in biliary tract surgery, and to provide protection for improvements of therapeutic effect and safety of biliary tract surgery.MethodThe relevant literatures about studies on NIRFI in the biliary tract surgery in recent years were reviewed.ResultsThe NIRFI had been preliminarily used in the surgical treatment of benign and malignant biliary diseases, and had shown its unique value in cholangiography. It provided a new method for effectively avoiding surgical complications, shortening operation time, reducing the rate of conversion to open surgery, evaluating blood supply of bile duct and improving the safety of operation.ConclusionsNIRFI has achieved notable successes in treatment of biliary tract diseases. With future application of fluorescence imaging in near infra-red Ⅱ window and new specific fluorescence targeting molecules, this technique will highlight its more important values in biliary surgery.

    Release date: Export PDF Favorites Scan
  • A control study of indocyanine green fluorescence imaging in bile duct reexploration

    Objective To investigate the value of indocyanine green fluorescence imaging in common bile duct reexploration. Methods The clinical data of 32 patients who underwent open common bile duct reexploration in the Affiliated Hospital of Southwest Medical University from January 2018 to December 2020 were collected retrospectively. All patients divided into the control group (conventional exploration group, 20 patients) and the fluorescence imaging group (using indocyanine green fluorescence imaging, 12 patients) according to the operational manner. The intraoperative and postoperative results of two groups were analyzed. Results The operative time [(165.2±6.9) min vs. (130.8±5.5) min], the time to find extrahepatic bile duct [(43.9±3.8) min vs. (23.1±4.1) min] and the amount of bleeding [(207.7±7.7) mL vs. (127.5±15.3) mL] in the control group were longer or more than those in the fluorescence imaging group (P<0.05). The incidence of postoperative infection in the control group [7 cases (35.0%) vs. 0 cases (0.0%)] and the length of hospital stay [(10.8±2.8) d vs. (7.1±1.3) d] were higher or longer than those in the fluorescence imaging group (P<0.05). There were no significant difference between the two groups in the incidence of postoperative bile fistula [6 cases (30.0%) vs. 2 cases (16.7%)] and the incidence of residual stones [3 cases (15.0%) vs. 3 cases (25.0%), P>0.05]. Conclusion Indocyanine green fluorescence imaging appears to be a feasible, expeditious, useful, and effective imaging method while performing reexploration.

    Release date: Export PDF Favorites Scan
  • Evaluation of blood perfusion of parathyroid glands by indocyanine green fluorescence imaging during total thyroidectomy

    Objective To explore the accuracy and efficiency of indocyanine green fluorescence (ICGF) imaging in evaluating blood perfusion of parathyroid gland (PG) during total thyroidectomy. Methods Seventy patients who underwent total thyroidectomy and bilateral central lymph node dissection for papillary thyroid carcinoma (PTC) from March 2021 to December 2021 were enrolled and randomly divided into experimental group (ICGF imaging, n=35) and control group (normal treatment, n=35). Blood perfusion of PGs was evaluated by ICGF imaging and naked eye in each group respectively. The perfusion of PGs, incidence of hypoparathyroidism, and number of autotransplanted PGs were analyzed between the two groups. Results There was no difference between two groups in the incidence of transient hypoparathyroidism (P=0.339), and no one occurred permanent hypoparathyroidism. More PGs were autotransplanted in the experimental group compared to the control group (P<0.001). At least one PG with good perfusion in the experimental group predicted an extremely high rate of normal parathyroid hormone levels of the patients postoperatively than the control group (P=0.003). Conclusion ICGF imaging can evaluate the blood perfusion of PGs accurately and guide their autotransplantation.

    Release date: Export PDF Favorites Scan
  • Progress of autofluorescence in the study of parathyroid gland

    Objective To summarize the development, clinical application, advantages and disadvantages, and future prospects of parathyroid autofluorescence in recent years. MethodThe literatures related to the research progress of parathyroid autofluorescence in recent years were searched, and launched a specific discussion. Results Autofluorescence of parathyroid gland was still in its infancy at home and abroad. The existing studies had shown that this technique was superior to visual recognition and could reduce the incidence of postoperative complications. Autofluorescence technology had shown some advantages in identifying parathyroid gland during operation, and its mechanism research and related equipment improvement should be focused in the future. ConclusionAutofluorescence technique is of great value in the identification of parathyroid glands in patients undergoing thyroidectomy or parathyroidectomy.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next