A method of ultrasonic simulation based on the FIELD II software platform for carotid artery plaque was proposed according to the analysis for geometrical shape, tissue characteristics and acoustic properties of carotid artery plaques in clinic, and then a simulation system was developed by using the MATLAB graphical user interface (GUI). In the simulation and development, a three-dimensional geometric model of blood vessel with plaques was set up by using the metaball implicit surface technique, and a tissue model was established based on the scatterers with spatial position of gamma random distribution. Comparison of the statistical and geometrical characteristics from simulated ultrasound B-mode images with those based on clinical ones and preset values, the results fully demonstrated the effectiveness of the simulation methods and system.
Due to their diverse types, complex causes, high incidence, and difficult treatment, lung diseases have become major killers threatening human life and health, and some lung diseases have a significant impact on alveolar morphology and histology. Numerical simulation of alveolar mechanical response, alveolar flow field information, multiphase flow, and material transport based on computational fluid dynamics is of great significance for lung disease diagnosis, clinical treatment, and in vitro experiments. Starting from the simplification and pathological differences of geometric and mechanical models, this paper analyzes and summarizes the conditions and application scenarios of the airflow dynamics calculation method in pulmonary alveoli, to provide a reference for further simulation and application of the alveolar region.
The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.