west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "locking plate" 30 results
  • BRIDGING FIXATION WITH LONG LOCKING PLATE FOR DISPLACED MIDSHAFT CLAVICULAR FRACTURES

    Objective To evaluate the effectiveness of bridging fixation with long locking plate for displaced midshaft clavicular fractures. Methods Between October 2010 and December 2011, 18 patients with displaced midshaft clavicular fracture were treated with reduction and bridging fixation with 9 or 10 holes locking plate. There were 17 males and 1 female with an average age of 47 years (range, 23-82 years). Fracture was caused by traffic accident in 6 cases, by falling in 10 cases, by crushing in 1 case, and by crashing object in 1 case. All fractures were closed and displaced or shortened (range, 2.1-3.4 cm; mean, 2.62 cm) with angulation deformity. According to Robinson classification criteria, 5 cases were rated as type 2B1 and 13 as type 2B2. The duration from injury to surgery was 5 hours to 19 days (mean, 5 days). The fracture healing time and complication were recorded; the effectiveness evaluation was performed with Constant-Murley score and satisfaction to appearance. Results No neurologic or vascular complication occurred with primary healing of incision. All patients were followed up 12-22 months (mean, 14.7 months). The fracture healing time was 9-14 weeks (mean, 11.4 weeks). During follow-up, no loosening or breakage of internal fixator was observed. The Constant-Murley score was 82-98 (mean, 92.4) at last follow-up; the satisfaction rate of appearance was 88.9% (16/18). Conclusion Bridging fixation with long locking plate is an effective method for treatment of displaced midshaft clavicular fractures. Preserved blood supply and stable angle are important to fracture healing.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • PRELIMINARY EFFECTIVENESS OF I.T.S. LOCKING PLATE FOR INTRA-ARTICULAR CALCANEAL FRACTURES

    Objective To summarize the preliminary effectiveness of I.T.S. locking plate for intra-articular calcaneal fractures. Methods Between July 2010 and July 2011, 18 cases of intra-articular calcaneal fractures were treated. There were 10 males and 8 females with an average age of 46 years (range, 25-64 years). According to Sanders classification system, there were 3 cases of type II, 9 cases of type III, and 6 cases of type IV. The disease duration was 5-11 days (mean, 6 days). Open reduction and internal fixation with I.T.S. locking plate were performed via an L-shaped lateral extending incision. Results Superficial infection occurred in 1 case, and was cured after dressing changing; healing of incision by first intention was obtained in the other cases. Sixteen cases were followed up 14 months on average (range, 12-18 months). X-ray films demonstrated the bone union in all cases with an average union time of 12 weeks (range, 10-14 weeks). No implant failure or irritation of peroneal tendon occurred during follow-up. X-ray films showed subtalar post-traumatic arthritis with mild pain in 1 case at 11 months after operation, which was relieved by conservative treatment. At last follow-up, the Bouml;hler angle was improved from (12.9 ± 3.2)° preoperatively to (33.8 ± 4.0)° postoperatively, showing significant difference (t=22.78, P=0.00); the Gissane angle was improved from (83.6 ± 6.4)° preoperatively to (119.9 ± 8.5)° postoperatively, showing significant difference (t=17.02, P=0.00). The visual analogue scale (VAS) score was 1.3 ± 1.2, and the ankle and hindfoot scale of American Orthopaedic Foot and Ankle Society (AOFAS) was 80.3 ± 7.9 at last follow-up. Conclusion Treatment of intra-articular calcaneal fracture with I.T.S. locking plate can obtain a stable fixation, which is a safe and effective method.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • EFFECTIVENESS OF T-LOCKING PLATE FOR INTERNAL FIXATION OF MEDIAL CLAVICLE FRACTURE

    To investigate the effectiveness of T-locking plate in treating medial clavicle fracture so as to find out a therapy with safety and stabil ity. Methods Between October 2006 and January 2009, 13 patients with medial clavicle fracture were treated with open reduction and T-locking plate fixation. There were 9 males and 4 females, aged 18-68 years (mean, 47 years), including 7 cases of traffic accident injury, 4 cases of fall ing injury from height, and 2 cases of heavy object hit injury. The locations were left side in 5 cases and right side in 8 cases. All cases were closed fracture. The disease duration was 1 hour to 14 days. Results All incisions healed by first intention after operation. The X-ray films showed good reduction of fracture and internal fixation. All the 13 patients were followed up 12-18 months (mean, 15 months). The average fracture heal ing duration was 8 weeks (range, 6-12 weeks). No compl ication of infection, nerve or blood vessel injury, hemopneumothorax, or internal fixation loosening or failure occurred. The anatomical medial clavicle structure as well asappearances and functions were restored. According to Rockwood’s score method, the results were excellent in 11 cases and good in 2 cases. Conclusion The internal fixation of T-locking plate in treating medial clavicle fracture has the advantages of good stabil ity and low risk. Besides, the patients can do functional exercises early and the shoulder joint function can be improved in great degree.

    Release date:2016-08-31 05:48 Export PDF Favorites Scan
  • EFFECTIVENESS OF VERY LOW PROFILE/VARIABLE ANGLE LOCKING PLATE INTERNAL FIXATION IN TREATMENT OF POSTERIOR Pilon FRACTURES EXTENDING TO MEDIAL MALLEOLUS BY POSTEROMEDIAL APPROACH

    ObjectiveTo evaluate the effectiveness of very low profile/variable angle locking plate (VLP) internal fixation for posterior Pilon fractures extending to the medial malleolus by posteromedial approach. MethodsA retrospective analysis was made on the clinical data from 13 patients with posterior Pilon fractures extending to the medial malleolus between December 2011 and August 2012. There were 4 males and 9 females with an average age of 48.9 years (range, 23-68 years). Fractures were caused by falling in 9 cases and by traffic accident in 4 cases. The locations were the left ankle in 6 cases and the right ankle in 7 cases. According to the Orthopedic Trauma Association (OTA) classification, 6 cases were rated as type 43B1, 4 cases as type 43B2, and 3 cases as type 43B3. Twelve cases had fibular fractures, including 11 cases of Denis-Weber type B, 1 case of Denis-Weber type C. The interval of injury and operation was 7-14 days (mean, 11.4 days). Open reduction was performed and VLP internal fixation was used for posterior malleolar fracture by posteromedial approach. ResultsPrimary healing of incision was obtained in all patients. Tibial nerve palsy was observed in 2 cases, and was cured after oral administration of mecobalamin. Twelve cases were followed up 12-18 months (mean, 14.5 months). According to the Burwell-Charnley's radiological evaluation system, 11 cases achieved anatomical reduction, 1 case achieved fair reduction. The fracture union time was 3-6 months (mean, 3.7 months). No loosening or breakage of internal fixation occurred during follow-up. According to the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, the results were excellent in 7 cases, good in 4, and fair in 1; the excellent and good rate was 91.7%. ConclusionVLP internal fixation for posterior Pilon fractures extending to the medial malleolus by posteromedial approach can achieve good short-term effectiveness. The high quality of reduction is acquired under direct vision with low rate of soft tissue complications.

    Release date: Export PDF Favorites Scan
  • DEVELOPMENT OF POLYAXIAL LOCKING PLATE SCREW SYSTEM OF SACROILIAC JOINT

    ObjectiveTo develop an instrument for sacroiliac joint fixation with less injury and less complications. MethodsFirstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups:group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. ResultsAccording to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P>0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than that in group C, but there was no significant difference between group B and group C (P>0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. ConclusionThe polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw direction. The simulated application test shows satisfactory fixing effect.

    Release date: Export PDF Favorites Scan
  • Short-term effectiveness of polyaxial locking plate for fixation of femoral neck fracture in middle-aged and elderly patients

    Objective To evaluate the feasibility and short-term effectiveness of polyaxial locking plate for fixation of femoral neck fracture in the middle-aged and elderly patients. Methods A retrospective analysis was made on the clinical data of 13 patients with femoral neck fracture undergoing fixation with polyaxial locking plates between September 2013 and June 2015 (group A) and 13 patients with femoral neck fracture undergoing fixation with three cannulated screws in the same period (group B). There was no significant difference in gender, age, side, cause of injury, Garden type, type of fracture position, type of Pauwels angle, Singh index, time between injury and operation, and preoperative complications between 2 groups (P>0.05). The femoral neck shortening at 1 year postoperatively, and fracture nonunion, femoral head necrosis, and Harris hip score at last follow-up were compared between 2 groups. Results The follow-up time was (19.23±3.98) months in group A and (18.00±3.61) months in group B, showing no significant difference between 2 groups (t=2.063,P=0.417). No femoral head necrosis occurred in group A, but head necrosis occurred in 1 case of group B, and hemiarthroplasty was performed. There was no significant difference in the rate of femoral head necrosis between 2 groups (χ2=0.000,P=1.000). Bone union was obtained in the other patients of 2 groups. The Harris hip score of group A (85.23±2.95) was significantly higher than that of group B (81.92±3.64) at last follow-up (t=2.064,P=0.018). No infection or internal fixation failure occurred in 2 groups. One case had pain at the outer thigh at 1 month after operation in group A, but pain relief was achieved at 3 months after operation. At 1 year after operation, no femoral neck shortening occurred in group A, but degree I, II, and III femoral neck shortening was observed in 3, 2, and 8 cases of group B, respectively, showing significant difference between 2 groups (Z=–4.714,P=0.000). Conclusion Although fixation with polyaxial locking plate for femoral neck fracture in the middle-aged and elderly patients has similar femoral head necrosis rate to fixation with cannulated screws, it has advantages in preventing neck shortening and improving hip joint function after operation.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
  • Surgical techniques and effectiveness of volar locking plates for senile delayed distal radius fractures

    Objective To investigate the surgical technique and effectiveness of volar locking plates for senile delayed distal radius fractures. Methods Between October 2014 and September 2015, 25 cases of delayed distal radius fractures were treated by volar locking plates. There were 3 males and 22 females with an average age of 73 years (range, 65-87 years). Injury was caused by tumble in 19 cases and by traffic accident in 6 cases. All the cases had closed fracture. According to the AO classification, 10 cases were rated as type A2, 7 cases as type A3, 3 cases as type B3, and 5 cases as type C1. The manual reduction and plaster immobilization were performed in 18 cases first, but reduction failed; no treatment was given in 7 cases before surgery. The time from injury to surgery was from 33 to 126 days (mean, 61 days). Preoperatively, the volar tilting angle was (–16.0±3.1)°; the ulnar inclining angle was (10.8±7.0)°; the radial shortening was (11.2±3.6) mm; the wrist range of motion was (41.0±7.5)° in flexion and was (42.0±6.3)° in extension; and the grip strength was 33.0%±3.1% of normal side. Results All incisions healed primarily, and no postoperative complication occurred. The patients were followed up 1-1.5 years (mean, 1.3 years). The X-ray films showed that fracture union was achieved in all the patients, with the mean healing time of 9.2 weeks (range, 8-12 weeks); the displacement of the articular surface was less than 1 mm. At last follow-up, the volar tilting angle was (13.1±3.2)°; the ulnar inclining angle was (21.9±4.6)°; the radial shortening was (2.0±1.1) mm; the wrist range of motion was (52.0±11.7)° in flexion and was (65.0±4.8)° in extension; and the grip strength was 84.0%±4.2% of normal side; all showed significant difference when compared with preoperative ones (P<0.05). According to the Gartland and Werley score, the results were excellent in 15 cases, good in 6 cases, fair in 2 cases, and poor in 2 cases at last follow-up; the excellent and good rate was 84%. Conclusion By the good design of the volar locking plate and the command of surgical techniques, good effectiveness can be achieved in the treatment of senile delayed distal radius fracture.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • A finite element analysis of petal-shaped poly-axial locking plate fixation in treatment of Y-shaped patellar fracture

    Objective To establish the finite element model of Y-shaped patellar fracture fixed with titanium-alloy petal-shaped poly-axial locking plate and to implement the finite element mechanical analysis. Methods The three-dimensional model was created by software Mimics 19.0, Rhino 5.0, and 3-Matic 11.0. The finite element analysis was implemented by ANSYS Workbench 16.0 to calculate the Von-Mises stress and displacement. Before calculated, the upper and lower poles of the patella were constrained. The 2.0, 3.5, and 4.4 MPa compressive stresses were applied to the 1/3 patellofemoral joint surface of the lower, middle, and upper part of the patella respectively, and to simulated the force upon patella when knee flexion of 20, 45, and 90°. Results The number of nodes and elements of the finite element model obtained was 456 839 and 245 449, respectively. The max value of Von-Mises stress of all the three conditions simulated was 151.48 MPa under condition simulating the knee flexion of 90°, which was lower than the yield strength value of the titanium-alloy and patella. The max total displacement value was 0.092 8 mm under condition simulating knee flexion of 45°, which was acceptable according to clinical criterion. The stress concentrated around the non-vertical fracture line and near the area where the screws were sparse. Conclusion The titanium-alloy petal-shaped poly-axial locking plate have enough biomechanical stiffness to fix the Y-shaped patellar fracture, but the result need to be proved in future.

    Release date:2017-12-11 12:15 Export PDF Favorites Scan
  • Tunnel-type open reduction and internal fixation of rib fractures with titanium locking plate

    Objective To investigate the tunnel-type open reduction and internal fixation of rib fractures (ORIF) with titanium locking plate in traumatic rib fractures. Methods Clinical data of 10 patients with multiple rib fractures from June 2016 to January 2017 in the Sixth People’s Hospital Affiliated to Shanghai Jiaotong University were analyzed. There were 6 males and 4 males with an average age of 38.5±9.0 years (range, 30–63 years). All patients underwent emergency treatment, chest CT and ultrasound examination before they admitted to the hospital. According to rib fractures and injuries, patients were given the tunnel-type ORIF of rib fractures with titanium locking plates, the chest tube and negative suction drainage. The patients were followed up over three months. Results All patients were cured. There was no complication during follow-up. No wound infection and death occurred. Postoperative three-month follow-up showed that chest pain was significantly relieved without pulmonary atelectasis and pleural effusion or other complications. Conclusion Tunnel-type internal fixation of rib fractures with titanium locking plates is effective, which can quickly restore the stability and integrity of the thorax. Surgical procedure is simple and can get fast postoperative recovery to improve the patient's quality of life.

    Release date:2017-12-04 10:31 Export PDF Favorites Scan
  • Flexible internal fixation with locking plate for distal femoral fractures

    Objective To analyze the effectiveness of flexible internal fixation with locking plate for distal femoral fractures. Methods Between January 2015 and June 2016, 21 cases of distal femoral fractures were treated. There were 5 males and 16 females with an average age of 62 years (range, 32-88 years). Injury was caused by falling in 14 cases, by traffic accident in 5 cases, and by falling from height in 2 cases. The fractures located at the left side in 13 cases and the right side in 8 cases. Twenty cases were fresh closed fractures and 1 case was open fracture. According to AO/Association for the Study of Internal Fixation (AO/OTA) typing, there were 5 cases of type 33-A1, 3 of type 33-A2, 8 of type 33-A3, 2 of type 33-C2, and 3 of type 33-C3. The time from injury to operation was 3-13 days (mean, 6.5 days). Results All operation incisions healed primarily. Eighteen patients were followed up 12-24 months (mean, 16 months). All fractures healed, and the healing time was 8-24 weeks (mean, 16.6 weeks). The articular surface was smooth and the thigh length was recovered. No screw loosening, plate breakage, valgus or varus of the knee, stiff of the knee or non-unions occurred during follow-up. There was no significant difference in visual analogue scale (VAS) score between at 6 and 12 months after operation (P>0.05), and the difference was significant bewteen the other time points (P<0.05). There were significant differences in the range of motion of knee between 1 month and 3, 6, 12 months (P<0.05); there was no significant difference between 3, 6, and 12 months (P>0.05). There were significant differences in the Neer scores between 1, 3, 6, and 12 months after operation (P<0.05). According to Neer score criteria, the results were excellent in 12 cases and good in 6 cases at 12 months after operation. Conclusion Flexible internal fixation with locking plate for distal femoral fractures can get good functional recovery.

    Release date:2018-01-09 11:23 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content