Objective To investigate the current situation of self-monitoring of blood glucose (SMBG) in patients with type 2 diabetes mellitus (T2DM) in Sichuan province, and to analyze the influencing factors of SMBG, so as to provide evidence for improving the level of SMBG. Methods By the convenience sampling method, 410 patients with T2DM for more than 1 year were selected from 17 hospitals and community health service centers in 7 cities across Sichuan province, and their SMBG was investigated with a questionnaire. Results Among 410 eligible patients, the average frequency of SMBG was 7.3 times per month. There were 268 patients (65.4%) performed SMBG less than 4 times per month, 94 (22.9%) performed 4-15 times per month, 29 (7.1%) performed 6-29 times per month, and 19 (4.6%) performed over 30 times per month. Just 234 patients (57.1%) monitored the HbA1c in the past 6 months. FPG, 2-hour PPG and HbA1c were negatively correlated with the frequency of SMBG. The influencing factors of SMBG were insulin treatment and education. Conlusion The SMBG status in D2TM patients is relatively poor in Sichuan province, and the compliance of SMBG is expected to be improved by enhancing diabetic education.
Objective To review published literature on telemedicine in China using qualitative analysis. Methods Such databases as CBM, VIP, CNKI, and CSSCI were electronically and comprehensively searched for clinical studies related to telemedicine from inception to March 2013. References of the included studies were also retrieved. Two reviewers independently identified the literature according to inclusion and exclusion criteria, extracted data, and assessed the quality of the included studies. Then, qualitative analysis was performed in aspects of the application fields, range, and effects of the included studies. Result Finally, 19 studies were eligible for the analysis, including 16 quasi-randomized controlled trials and 3 observational studies. According to methodological evaluation standards (JBI, 2005), among 16 quasi-randomized controlled trials, 12 were of medium quality and four were of low quality; and 3 observational studies were all of low quality. The results of qualitative analysis showed that, literature on telemedicine had increased by year since 1995. However, the literature on relevant research of telemedicine had been published since 2002. The number of literature increased evenly and sporadically in journals. According to the classification of the application fields of telemedicine, 15 (80%) related to remote monitoring, especially related to remote fetal monitoring, 4 (21%) were remote consultation, and 3 (16%) were remote treatment. The results of 19 studies showed that, telemedicine had better effects than traditional medicine. Conclusion In China, literature related to telemedicine increases by year but the quality of them are low. High quality studies are further needed. The distribution of the application fields of telemedicine is uneven, most of which focuses on remote monitoring. The quality of research is low and need high-quality research in future. The therapeutic effects of telemedicine are better with accurate monitoring data and convenience to patients..
Objective To investigate the antihypertensive effects of continuous airway positive pressure( CPAP) plus antihypertensive drugs on patients with obstructive sleep apnea hypopnea syndrome ( OSAHS) and hypertension.Methods 82 OSAHS patients with hypertension were enrolled in this study. They were randomly divided into a CPAP treatment group( 44 patients, treated with antihypertensive drugs and CPAP) , and a control group( 38 patients, treated with antihypertensive drugs only) . All the patients were performed polysomnography and 24-hour blood pressure monitoring before and 12 weeks after the treatment. Results After 12 weeks treatment, except the systolic pressure in night time( nSBP) , all the parameters of 24-hour blood monitoring improved better in the CPAP group than in the control group( all P lt; 0. 05) . The blood pressure dropped to normal in 75. 0% ( 33/44) CPAP patients and in 52. 6% ( 20 /38) control patients. In the CPAP group, 8( 18. 2% ) cases were withdrawn from antihypertensive drugs, 13( 29. 5% )cases required single agents, and 9( 20. 5% ) cases required three agents to achieve blood pressure control.But in the control group, all the patients needed two or more antihypertensive agents, in which 23( 60. 6% )patients needed three agents to achieve blood pressure control. After the treatment, the patients with dipping pattern blood pressure increased from10 to 29( 22. 7% -65. 9% , P lt;0. 05) in the CPAP group, and from10to 14( 26. 3% -36. 8%, P gt;0. 05) in the control group. Conclusions Combination therapy with CPAP and antihypertensive drugs controls blood pressure better than antihypertensive medication only for OSAHS patients with hypertension with fewer types of antihypertensive agents or even withdrawal from antihypertensive medication in some patients.
Abstract: Cardiac transplantation is an effective therapeutic method for terminalstage heart diseases. The immunosuppressive treatment based on calcineurin inhibitors (CsA and FK506) is most commonly used, monoclonal antibodies are also used in some recipients as induction therapy before and/or after transplantation. Some new immunosuppressive drugs, such as Rapamycin and Everolimus, can not only inhibit the acute transplant rejection but also prevent cardiac vasculopathy. The application of some relatively nontraumatic tests, such as immunological indexes, cardiac markers and other serological parameters, are helpful for diagnosis and preventing postcardiac transplant rejection at early stage and improving the result of cardiac transplantation.
Abstract: Objective To evaluate the effect on gastroesophageal reflux and gastric emptying in the different route of gastroesophageal anastomosis objectively after esophagectomy for patients with midesophageal carcinoma. Methods Forty patients with midesophageal carcinoma were randomly divided into two groups. Esophageal bed group (n=20): the gastroesophageal anastomosis were performed while the stomach were pulled on through the esophageal bed after esophagectomy; endothoracic group (n=20): gastroesophageal anastomosis were performed while the stomach were pulled on in the thoracic cavity. Ten persons had no disease of digestive system and healthy volunteers were recruited as normal control group. 24-hour esophageal pH monitoring and radioisotope gastric emptying checkup were carried out in all experimental subjects 3 months after operation, so as to observe the changes of gastroesophageal reflux and gastric emptying. Results All of the patients’s operation were success. And no anastomotic leakage and no anastomotic stenosis. Three months after operation, the patients in both operation groups were with different level of reflux. DeMeester total appraise score, the times of regurgitation of gastric juice in 24h, gt;5 min reflux frequency, the longest time of keep reflux, pHlt;4.00 total time and pHlt;4.00 of total time percent, these targets in both operation groups were higher than those in control group (Plt;0.01) DeMeester total appraise score, the times of regurgitation of gastric juice in 24 hours, the longest time of keeping reflux, pHlt;4.00 of total time and pHlt;4.00 of total time percent in esophageal bed group were lower than those in endothoracic group(Plt;0.01). The recent period of gastric emptying percentage (GE) in both operative groups were lower than that in normal control group. GE in esophageal bed group experimental meal in the stomach after entering the 30,60,90,120,180 and 240 min were higher than those in endothoracic group. Conclusion After the operation of esophagogastric anastomosis through esophageal bed in upper aortic site,gastroesophageal reflux and delayed gastric emptying exist objectively, However, the technique is superior to the traditional technique to reduce the extent of gastroesophageal reflux and delayed gastric emptying, its mechanism might be the result of mechanical factors.
The body is at a hypo-coagulation status after the heart mechanic valve prosthesis replacement operation, and the incidence of anticoagulation complications is rather high because of that administration of warfarin may result in “anticoagulation vacuum” at an early stage. Moreover, the necessary application of other anticoagulation methods assisting the employment of warfarin have still not been scientifically normalized. Blood coagulation factor Ⅱ,Ⅶ, prothrombin fragment1+2 (F1+2 ), urine fibrimopeptide A (UFPA) , and International Normalized Ratio(INR), could exactly reflect the anticoagulation intensity 48-72 hours after the replacement operation,reasonable use of anticoagulant therapy as well as accurate and in-time monitoring methods is significant to reduce complications,elevate survival rate, and improve quality of life.
To introduce a micturition alert device dedicated to neurogenic bladders. Methods The design and mechanism of the micturition alert device were explained, the effectiveness was tested in a cranine experiment. Results The micturition alert device consisted of a permanent magnet sutured on the anterior bladder wall and a warning unit sutured on theinferior abdominal wall. The warning unit was assembled with a compass-l ike switch, a power supply, a buzzer and a power switch. Bladder volume determined the position of the magnet which determined the magnetic field at the point of the warning unit. The change of magnetic field was read by the warning unit. With increasing bladder volume from initial state to 200 mL in 8 dogs, the magnet moved cranially 32.8 mm averagely (from 31.3 mm to 34.1 mm) and the hand of warning unit turned 52° (from 47° to 57°). The value of the warning unit was correlated positively to the bladder volume (r =1.0, P lt; 0.01). If the desired bladder volume was determined as 150 mL to activate the warning unit to alarm in advance, the fullness of bladder was 147.6 mL averagely from135 mL to 160 mL, with an error less than 15 mL (10%). Conclusion The micturition alert device including a warning unit and permanent magnet could monitor bladder volume continuously and alarm in time for the patients with loss of micturition desire. It is simple, easily-made, cheap and conveniently used. It is worth of further study.
Objective To study major influential factors of the micturition alert device dedicated to neurogenic bladders for the product design and cl inical appl ication of the device. Methods One ferrite permanent magnet with thickness and diameter of 3 mm and 10 mm, respectively, and three NdFeB permanent magnets with the thickness of 3 mm and diameter of 10, 15 and 20 mm, respectively, were used. The effects of thickness of the abdominal wall as well as the position and type of permanent magnets on the micturition alert device dedicated to neurogenic bladders were measured in vitro simulated test, when the abdominal wall was set to 2, 3, 4, 5, 6, 7, 8 and 9 cm, respectively, and the position of permanent magnets was 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12 cm, respectively. The effect of the geomagnetic field on the device was measured under the condition that the thickness of the simulated abdominal wall was set to 2, 3, 4 and 5 cm, respectively,and the position of permanent magnets was 2, 3, 4, 5, 6, 7, 8, 9 and 10 cm, respectively. Results The value showed inthe warning unit was positively correlated with the position of the ferrite permanent magnet only when the thickness ofthe simulated abdominal wall was 2 cm (r=0.632, P lt; 0.05). The correlation between the value of the warning unit andthe position of NdFeB permanent magnets was significant (r gt; 0.622, P lt; 0.05), which was intensified with the increasingdiameter of NdFeB permanent magnets, but weakened with the increasing thickness of the simulated abdominal wall. The effect of the geomagnetic field was correlated with the exposition of the body, the position of the permanent magnet and the thickness of the abdominal wall. Conclusion The major influential factors of the micturition alert device dedicated to neurogenic bladder include the magnetism and location of the permanent magnet, the thickness of the abdominal wall and the geomagnetic field. These factors are correlated with and affect each other. Reasonable allocation of these factors may optimize the device.
Objective To investigate the biocompatibil ity of sil ica gel embedded permanent magnets of themicturition alert device dedicated to neurogenic bladder. Methods According to the national standards of biologicalevaluation of medical equipment (GB/T 16886), Shanghai Biomaterial Research and Test Center was confided to evaluate the biocompatibil ity of sil ica gel embedded permanent magnets both in vitro and in vivo, including cytotoxicity test, sensitization test, primary skin irritant test and acute general toxicity test. The cytotoxicity test was performed according to the agar diffusion method. The L929 cell discoloration index and cell lysis index were counted at 24 hours after the action of the specimen. The sensitization test was performed according to the maximal dose method. The skin response was evaluated in 30 male albino guinea-pigs at 24 and 48 hours after the routine induction and provocation of leaching l iquors of the specimen. The primary skin irritant test was evaluated in 2 male healthy New Zealand rabbits according to the local tissue response at 24, 48 and 72 hours after intradermal injection of leaching l iquors of the specimen. The acute general toxicity test was evaluated in 10 male Kumming mice musculus albus according to animal condition at 4, 24, 48 and 72 hours after injection of leaching l iquors of the specimen through the caudal vein. Both the general reaction of canines and the pathology of the local bladder walls were observed at 2, 4 and 8 weeks after a permanent magnet was fixed on the anterior wall of urinary bladder in three canines. Results No sensitization, no stimulation and no acute general toxicity were observed except sl ight cytotoxicity to sil ica gel embeddedpermanent magnets. After implantation of a permanent magnet, the canines showed excellent tolerace, which manifested as no abnormal ity in spirit, appetite, urine and stool, healed wounds and no infection. Adhesions occurred between the epiploon and the bladder wall around the permanent magnet in two canines at 2 and 4 weeks, and between the lower abdominal wall and the bladder wall around the permanent magnet in the other canine at 8 weeks. The local bladder wall below permanent magnet was thickened, the fibrous capsule around the permanent magnet was thin, but the bladder mucosa was normal. Inflammatory reaction such as congestion, edema and inflammatory cells lessened from the serosa layer to the mucosa layer microscopically. Conclusion Sil ica gel embedded permanent magnets used in the micturition alert device dedicated to neurogenic bladde has excellent biocompatibil ity and meet the criteria for cl inical appl ication.
Objective To investigate the effect of perioperative body temperature on the survival of skin flap grafting. Methods From July 2005 to November 2006, 50 cases of Ⅰ-Ⅱ grade patients undergoing elective skin flap grafting were randomly divided 2 groups. Pharyngeal temperature (PT) and skin temperature(ST) were monitored and recorded every 15 minutes. Operativetime, anesthetic time, time from the end of operation to extubation, the volume of blood transfusion, the volume of fluid transfusion and the flap survival 7 days after operation were recorded. In the experimental group, the body temperature was maintained in normal range with water market and forced air heater. In the control group, the body temperature was only monitored without any treatment. Results There were no significant differences in operating room temperature, operative time, anesthetic time, the volume of blood transfusion and fluid transfusion between 2 groups(Pgt;0.05). After induction, PT decreased gradually inboth groups during the first 45 minutes, compared with the time point of intubation(Plt;0.05),but there were no significant differences between the 2 groups(Pgt;0.05); and ST rose in both groups during the first45 minutes, compared with the time point of intubation (Plt;0.05). After 45 minutes of induction, in the experimental group, PT was in the normal range(36℃), and ST didn’t change compared with that of the timepoint of induction(Pgt;0.05). In the control group, both PT and ST decreasedgradually and timedependently compared with the time point of intubation (Plt;0.05). In the experimental group, PT and ST at each time point were higher than those in the control group (Plt;0.05). All the skin flap grafts survived in the experimental group, and skin flap grafts necrosed in 2 cases in the control group.Conclusion Keeping normal body temperature can improve the survival ofskin flap grafting. Therefore, the body temperature should be monitored and maintained in a normal range.