west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "monitoring" 92 results
  • Current Situation and Influencing Factors of Self-Monitoring of Blood Glucose in Type 2 Diabetic Patients in Sichuan Province

    Objective To investigate the current situation of self-monitoring of blood glucose (SMBG) in patients with type 2 diabetes mellitus (T2DM) in Sichuan province, and to analyze the influencing factors of SMBG, so as to provide evidence for improving the level of SMBG. Methods By the convenience sampling method, 410 patients with T2DM for more than 1 year were selected from 17 hospitals and community health service centers in 7 cities across Sichuan province, and their SMBG was investigated with a questionnaire. Results Among 410 eligible patients, the average frequency of SMBG was 7.3 times per month. There were 268 patients (65.4%) performed SMBG less than 4 times per month, 94 (22.9%) performed 4-15 times per month, 29 (7.1%) performed 6-29 times per month, and 19 (4.6%) performed over 30 times per month. Just 234 patients (57.1%) monitored the HbA1c in the past 6 months. FPG, 2-hour PPG and HbA1c were negatively correlated with the frequency of SMBG. The influencing factors of SMBG were insulin treatment and education. Conlusion The SMBG status in D2TM patients is relatively poor in Sichuan province, and the compliance of SMBG is expected to be improved by enhancing diabetic education.

    Release date: Export PDF Favorites Scan
  • Status Quo of Telemedicine in China

    Objective To review published literature on telemedicine in China using qualitative analysis. Methods Such databases as CBM, VIP, CNKI, and CSSCI were electronically and comprehensively searched for clinical studies related to telemedicine from inception to March 2013. References of the included studies were also retrieved. Two reviewers independently identified the literature according to inclusion and exclusion criteria, extracted data, and assessed the quality of the included studies. Then, qualitative analysis was performed in aspects of the application fields, range, and effects of the included studies. Result Finally, 19 studies were eligible for the analysis, including 16 quasi-randomized controlled trials and 3 observational studies. According to methodological evaluation standards (JBI, 2005), among 16 quasi-randomized controlled trials, 12 were of medium quality and four were of low quality; and 3 observational studies were all of low quality. The results of qualitative analysis showed that, literature on telemedicine had increased by year since 1995. However, the literature on relevant research of telemedicine had been published since 2002. The number of literature increased evenly and sporadically in journals. According to the classification of the application fields of telemedicine, 15 (80%) related to remote monitoring, especially related to remote fetal monitoring, 4 (21%) were remote consultation, and 3 (16%) were remote treatment. The results of 19 studies showed that, telemedicine had better effects than traditional medicine. Conclusion In China, literature related to telemedicine increases by year but the quality of them are low. High quality studies are further needed. The distribution of the application fields of telemedicine is uneven, most of which focuses on remote monitoring. The quality of research is low and need high-quality research in future. The therapeutic effects of telemedicine are better with accurate monitoring data and convenience to patients..

    Release date: Export PDF Favorites Scan
  • Antihypertensive Effects of Continuous Airway Positive Pressure Plus Antihypertensive Drugs on OSAHS Patients with Hypertension

    Objective To investigate the antihypertensive effects of continuous airway positive pressure( CPAP) plus antihypertensive drugs on patients with obstructive sleep apnea hypopnea syndrome ( OSAHS) and hypertension.Methods 82 OSAHS patients with hypertension were enrolled in this study. They were randomly divided into a CPAP treatment group( 44 patients, treated with antihypertensive drugs and CPAP) , and a control group( 38 patients, treated with antihypertensive drugs only) . All the patients were performed polysomnography and 24-hour blood pressure monitoring before and 12 weeks after the treatment. Results After 12 weeks treatment, except the systolic pressure in night time( nSBP) , all the parameters of 24-hour blood monitoring improved better in the CPAP group than in the control group( all P lt; 0. 05) . The blood pressure dropped to normal in 75. 0% ( 33/44) CPAP patients and in 52. 6% ( 20 /38) control patients. In the CPAP group, 8( 18. 2% ) cases were withdrawn from antihypertensive drugs, 13( 29. 5% )cases required single agents, and 9( 20. 5% ) cases required three agents to achieve blood pressure control.But in the control group, all the patients needed two or more antihypertensive agents, in which 23( 60. 6% )patients needed three agents to achieve blood pressure control. After the treatment, the patients with dipping pattern blood pressure increased from10 to 29( 22. 7% -65. 9% , P lt;0. 05) in the CPAP group, and from10to 14( 26. 3% -36. 8%, P gt;0. 05) in the control group. Conclusions Combination therapy with CPAP and antihypertensive drugs controls blood pressure better than antihypertensive medication only for OSAHS patients with hypertension with fewer types of antihypertensive agents or even withdrawal from antihypertensive medication in some patients.

    Release date:2016-08-30 11:53 Export PDF Favorites Scan
  • Immunosuppressive Treatment and Immunological Monitoring after Cardiac Transplantation

    Abstract: Cardiac transplantation is an effective therapeutic method for terminalstage heart diseases. The immunosuppressive treatment based on calcineurin inhibitors (CsA and FK506) is most commonly used, monoclonal antibodies are also used in some recipients as induction therapy before and/or after transplantation. Some new immunosuppressive drugs, such as Rapamycin and Everolimus, can not only inhibit the acute transplant rejection but also prevent cardiac vasculopathy. The application of some relatively nontraumatic tests, such as immunological indexes, cardiac markers and other serological parameters, are helpful for diagnosis and preventing postcardiac transplant rejection at early stage and improving the result of cardiac transplantation.

    Release date:2016-08-30 06:13 Export PDF Favorites Scan
  • Clinical Study of Gastroesophageal Reflux and Gastric Emptying after Esophagectomy with Gastric Replacement Through Esophageal Bed

    Abstract: Objective To evaluate the effect on gastroesophageal reflux and gastric emptying in the different route of gastroesophageal anastomosis objectively after esophagectomy for patients with midesophageal carcinoma. Methods Forty patients with midesophageal carcinoma were randomly divided into two groups. Esophageal bed group (n=20): the gastroesophageal anastomosis were performed while the stomach were pulled on through the esophageal bed after esophagectomy; endothoracic group (n=20): gastroesophageal anastomosis were performed while the stomach were pulled on in the thoracic cavity. Ten persons had no disease of digestive system and healthy volunteers were recruited as normal control group. 24-hour esophageal pH monitoring and radioisotope gastric emptying checkup were carried out in all experimental subjects 3 months after operation, so as to observe the changes of gastroesophageal reflux and gastric emptying. Results All of the patients’s operation were success. And no anastomotic leakage and no anastomotic stenosis. Three months after operation, the patients in both operation groups were with different level of reflux. DeMeester total appraise score, the times of regurgitation of gastric juice in 24h, gt;5 min reflux frequency, the longest time of keep reflux, pHlt;4.00 total time and pHlt;4.00 of total time percent, these targets in both operation groups were higher than those in control group (Plt;0.01) DeMeester total appraise score, the times of regurgitation of gastric juice in 24 hours, the longest time of keeping reflux, pHlt;4.00 of total time and pHlt;4.00 of total time percent in esophageal bed group were lower than those in endothoracic group(Plt;0.01). The recent period of gastric emptying percentage (GE) in both operative groups were lower than that in normal control group. GE in esophageal bed group experimental meal in the stomach after entering the 30,60,90,120,180 and 240 min were higher than those in endothoracic group. Conclusion After the operation of esophagogastric anastomosis through esophageal bed in upper aortic site,gastroesophageal reflux and delayed gastric emptying exist objectively, However, the technique is superior to the traditional technique to reduce the extent of gastroesophageal reflux and delayed gastric emptying, its mechanism might be the result of mechanical factors.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
  • Usage and Monitoring of Anticoagulant During Earlier Period after Mechanical Prosthetic Valve Replacement

    The body is at a hypo-coagulation status after the heart mechanic valve prosthesis replacement operation, and the incidence of anticoagulation complications is rather high because of that administration of warfarin may result in “anticoagulation vacuum” at an early stage. Moreover, the necessary application of other anticoagulation methods assisting the employment of warfarin have still not been scientifically normalized. Blood coagulation factor Ⅱ,Ⅶ, prothrombin fragment1+2 (F1+2 ), urine fibrimopeptide A (UFPA) , and International Normalized Ratio(INR), could exactly reflect the anticoagulation intensity 48-72 hours after the replacement operation,reasonable use of anticoagulant therapy as well as accurate and in-time monitoring methods is significant to reduce complications,elevate survival rate, and improve quality of life.

    Release date:2016-08-30 06:25 Export PDF Favorites Scan
  • Accuracy of Newer-generation Home Blood Glucose Meter in Patients with IGR and Newly-diagnosed Type 2 Diabetes Mellitus

    Objective To evaluate the accuracy of newer-generation home blood glucose meter (Accu-Check? Integra) in patients with impaired glucose regulation (IGR) and newly-diagnosed type 2 diabetes mellitus. Methods A cross-sectional study was performed on 109 cases with newly-diagnosed type 2 diabetes or IGR who were asked to take oral glucose tolerance test (OGTT), while paired samples, that were Accu-Check? Integra in capillary blood glucose (CBG) and laboratory glucose in venous plasma glucose (VPG ), were taken simultaneously. Taking VPG as the reference value, the accuracy of the home glucose meter was assessed according to the international standardization organization (ISO), including, the accuracy was studied by means of Median absolute difference (Median AD) and Median absolute relative difference (Median RAD), the consistency of CBG and VPG was studied by Clarke Error Grid analysis, the correlation of CBG and VPG was analyzed according to liner regression analysis, and the sensitivity and specificity for hyperglycemia were also calculated. Results There were 292 VPG values paired with CBG values, among which 93.49% of CBG values met ISO home glucose meter criteria, the median AD was 7.2 mg/dL, and the median RAD was 4.76%. Paired glucose measurements from the Accu-Check Integra meter and laboratory glucose measurement demonstrated that 100% of paired points in the overall subject population fell in zones A and B of the Clarke Error Grid. The CBG value was well correlated to VPG value in the overall level, and the sensitivity and specificity were 94.6% and 95.7% respectively for hyperglycemia. Conclusion The newer-generation home blood glucose meter (Accu-Check? Integra) demonstrates a high degree of accuracy, and it can precisely report the real value of blood glucose.

    Release date:2016-09-07 10:59 Export PDF Favorites Scan
  • International Comparative Analyses of Incidents Reporting Systems for Healthcare Risk Management△

    Objective To compare administration of incidence reporting systems for healthcare risk management in the United Kingdom, the United States, Canada, Australia, and Taiwan, and to provide evidence and recommendations for healthcare risk management policy in China. Methods We searched the official websites of the healthcare risk management agencies of the four countries and one district for laws, regulatory documents, research reports, reviews, and evaluation forms concerned with healthcare risk management and assessment. Descriptive comparative analysis was performed on relevant documents. Results (1) A total of 142 documents were included in this study. The United States had the most relevant documents (68). (2) The type of incidents from reporting systems has expanded from medication errors and hospital-acquired infections to near-misses, and now includes all patient safety incidents. (3) The incidence-reporting systems can be grouped into two models: government-led and legal/regulatory/NGO-collaborative. (4) In two cases, reporting systems were established for specific incident types: One for death or serious injury events (the sentinel events database in Britain, SIRL), and one for healthcare-associated infections (NHSN in America). (5) Compared to the four countries, Taiwan’s system put more emphasis on public welfare, confidentiality, and information sharing. The contents of reporting there covered every aspect of risk management to create a more secure environment. Conclusion (1) Britain’s national reporting and learning system was representative of a government-led model; (2) The United States was the earliest country to have a reporting system, which included a limited range of incident types. Management of incidents became more reliable with increased application of laws, regulations, and guidances; (3) Both the Canadian and the Australian systems drew from the American experience and are still developing; (4) The Taiwanese system was comprehensive and is an instructional case.

    Release date:2016-09-07 11:03 Export PDF Favorites Scan
  • Risk Monitoring of Biologicals Derived from Adverse Reaction Management of Natalizumab: A Systematic Review Based on Serious Adverse Reaction Reports and Related Regulatory Documents

    Objective To analyze the withdrawal reason of natalizumab in depth based on the serious adverse reaction reports and approval channel, and to provide decision references for more safe and effective report method of other biologicals. Methods We searched MEDLINE, EMbase, and the official websites of Food and Drug Administration (FDA) for case reports, approval channel, and the relevant information of drug marketing or withdrawal. Results Four case reports and fourteen official reports were included. Three cases of progressive multifocal leukoencephalopathy (PML) were reported in the clinical trials after natalizumab’s initially approval with two dead and one disabled, which could be retrieved by hemodialysis (2 cases hitherto). Consequently, multiple sclerosis (MS) patients were willing to bear the risk. Two cases of natalizumab-related PML (0.06‰) were confirmed in 32 000 patients without death report after two years of its remarketing, in July 2008. Another PML patient was reported in October 2008. Because of its non-substitutability for treating MS and Crohn disease (CD), FDA announced that patients could still use natalizumab under the close monitoring. Conclusion (1) The most serious adverse reaction of treating MS and CD with natalizumab is PML, but it can be preventable and curable now. The monitoring findings of efficacy and adverse reaction during the postmarketing indicate that the review system is perfect and practicable relatively, and can give references for other high-risk drugs on the fast or standard approval channel, for example, Chinese medicine injection can draw lessons from it. (2) The remarketing of natalizumab not only provide significant risk management precedent for other drug-development firms, but also brings hope to the remarketing or relaunching clinical trials for the suspected sideeffect drugs. (3) Because of the fast-track reviewing of natalizumab and the overlap between the research of Good Clinical Practice (GCP) and the post-marketing evaluation, we should continue to track the information and provide new evidence.

    Release date:2016-09-07 02:08 Export PDF Favorites Scan
  • Evidence-Based Safety Reassessment of Post Marketed Drug - Importance of Recall of Refecoxib

    This article aims to review the recall of refecoxib which increases the incidence of cardiovascular and cerebrovascular diseases and to find the methods to solve problems in post marked monitoring of drug safety.

    Release date:2016-09-07 02:25 Export PDF Favorites Scan
10 pages Previous 1 2 3 ... 10 Next

Format

Content