find Keyword "percutaneous screw implantation" 1 results
  • The safety of TiRobot-guided percutaneous transpedicular screw implantation

    ObjectiveTo evaluate the safety of TiRobot-guided percutaneous transpedicular screw implantation.MethodsThe medical records of 158 patients with thoracolumbar fractures and lumbar degenerative diseases who underwent percutaneous transpedicular screw implantation were retrospectively analyzed between January 2018 and December 2020. The patients were divided into trial group (TiRobot-guided screw implantation, 86 cases) and control group (fluoroscopy-guided screw implantation, 72 cases). There was no significant difference in gender, age, pathology, lesion segment, and the average number of screw implantation per case (P>0.05). The operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency were compared between the two groups. One day postoperatively, the convergence angle was measured and the penetration of the pedicle cortex was evaluated according to Gertzbein-Robbins classification standard.ResultsThe operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency of the trial group were significantly lesser than those of control group (P<0.05).One day postoperatively, the convergence angle of trial group was (21.10±4.08)°, which was significantly larger than control group (19.17±3.48)° (t=6.810, P=0.000). According to the Gertzbein-Robbins classification standard, 446 pedicle screws were implanted in trial group, trajectories were grade A in 377 screws, grade B in 46 screws, grade C in 23 screws, and the accuracy of screw implantation was 94.8%; 380 pedicle screws were implanted in control group, trajectories were grade A in 283 screws, grade B in 45 screws, grade C in 44 screws, grade D in 6 screws, grade E in 2 screws, and the accuracy of screw implantation was 86.3%. There was significant difference in the accuracy of screw implantation between the two groups (χ2=25.950, P=0.000). ConclusionCompared with traditional percutaneous transpedicular screw implantation, TiRobot-guided percutaneous transpedicular screw implantation can improve the accuracy of screw implantation, reduce radiation exposure, and improve surgical safety, which has a good application prospect.

    Release date:2021-06-30 04:43 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content