ObjectiveTo evaluate the effectiveness and safty of posterior popliteal fossa S-shaped incision with double-window approach for the treatment of posterior column of tibial plateau fractures.MethodsA retrospective analysis was made on the clinical data of 13 patients with complex tibial plateau fractures involving both posteromedial and posterolateral columns between May 2015 and July 2017. There were 9 males and 4 females, aged 33-64 years (mean, 46.5 years). The causes of injury included traffic accident in 5 cases, falling from height in 2 cases, falling from electric bicycle in 4 cases, and falling because of skiing in 2 cases. The preoperative range of motion of the affected knees was (35.1±9.2)°. The time from injury to surgery was 7-19 days (mean, 13.3 days). All patients underwent a posterior popliteal fossa S-shaped incision through the window of medial heads of gastrocnemius muscle (medial window) and the window between medial and lateral head of gastrocnemius muscle (popliteal fossa window) approaches. After a good visual control of fracture reduction, both posteromedial and posterolateral columns of tibial plateau fractures were fixed with buttress plate respectively. Bone union, limb alignment, articular surface, and range of motion were estimated after operation. The American Hospital for Special Surgery (HSS) score was used to evaluate functional outcomes of knees.ResultsAfter operation, 1 patient had fat liquefaction and dehiscence of incision, which healed after expanding the wound; the other patients’ incisions healed by first intention, and no vascular or nerve injury occurred during operation. All the 13 patients were followed up 12-18 months (mean, 16 months). The X-ray films showed that all patients obtained good fracture unions, the fracture healing time was 14-22 weeks (mean, 18 weeks). At 12 months after operation, the articular surface was smooth without collapse, and the knee range of motion was (109.5±13.6)°, showing significant difference when compared with preoperative value (t=18.879, P=0.000). No complication of infection, re-displacement of fracture, or secondary varus/valgus deformity was observed during follow-up. The HSS score was 82-96 (mean, 89.6) at 12 months after operation, with the result of excellent in 10 cases and good in 3 cases.ConclusionThe posterior column fracture of tibial plateau involving both posteromedial and posterolateral columns treated by double-window approach through posterior popliteal fossa S-shaped incision is safe and effective, with satisfactory results and good recovery of knee joint function.
ObjectiveTo explore the effectiveness of a new H-shaped anatomical titanium plate in treatment of posterior wall/posterior column acetabular fractures.MethodsBetween March 2012 and April 2019, 46 patients with acetabular fractures involving posterior wall/posterior column were treated with the new H-shaped anatomical titanium plates. There were 28 males and 18 females. The age ranged from 20 to 70 years, with an average of 45.5 years. Among the patients, 34 cases were injured by traffic accidents and 12 cases by falling from height. The time from injury to operation ranged from 2 to 14 days, with an average of 7 days. According to Letournel-Judet classification, there were 12 cases of posterior wall fractures, 1 case of posterior column fracture, 3 cases of transverse fractures, 9 cases of transverse fractures involving posterior walls, 8 cases of posterior column and posterior wall fractures, 2 cases of anterior column and posterior semi-transverse fractures, 3 cases of T-shaped fractures, and 8 cases of double column fractures. Matta reduction standard was used to evaluate fracture reduction and Merle d’Aubign-Postel score was used to evaluate hip joint function.ResultsAll operations were successfully completed. The time of posterior operation was 60-120 minutes, with an average of 80 minutes. The amount of intraoperative blood loss ranged from 200 to 600 mL, with an average of 300 mL. All the incisions healed by first intention and no infection, deep vein thrombosis, or sciatic nerve injury occurred. All 46 patients were followed up 6-72 months, with an average of 37 months. According to Matta reduction standard, 40 cases obtained anatomic reduction, 4 cases satisfactory reduction, 2 cases unsatisfactory reduction, and the satisfaction rate was 95.7% (44/46). All fractures healed, and the healing time was 3-6 months, with an average of 4.3 months. No internal fixation failure occurred during the follow-up. At last follow-up, the Merle d’Aubign-Postel score ranged from 6 to 18 (mean, 15.5), including 38 cases of excellent, 4 cases of good, 2 cases of fair, and 2 cases of poor, with an excellent and good rate of 91.3% (42/46). Heterotopic ossification occurred in 4 cases, traumatic arthritis in 4 cases, and osteonecrosis of femoral head in 2 cases after operation.ConclusionFor acetabular fractures involving posterior wall/posterior column, the new H-shaped anatomical titanium plate can provide stable fixation, satisfactory reduction, and good recovery of hip function.