Objective To evaluate the incidence of heterotopic ossification (HO) after single-level Bryan cervical artificial disc replacement, and to identify the relationship between HO and the effectiveness. Methods The cl inical data of 48 patients undergoing single-level Bryan cervical artificial disc replacement between October 2005 and October 2007 were reviewedretrospectively. There were 27 males and 21 females with an average age of 40.5 years (range, 33-51 years), including 8 cases of cervical myelopathy, 27 cases of nerve root cervical spondylosis, and 13 cases of mixed cervical spondylosis with an average disease duration of 10.3 months (range, 2-14 months). The involved segments included C3, 4 in 3 cases, C4, 5 in 6 cases, C5, 6 in 30 cases, and C6, 7 in 9 cases. The outcomes were evaluated using Visual Analogue Scale (VAS) score, the neck disabil ity index (NDI), and cervical range of motion (ROM). According to patients with or without HO, 48 patients were divided into 2 groups (HO group and no HO group). VAS score, NDI, and cervical ROM were compared between 2 groups at 1, 2, 3, and 4 years after operation. Results No severe complication occurred during and after operation in all patients. Forty-eight patients were followed up 48-72 months (mean, 56.6 months). VAS score and NDI were significantly improved when compared with preoperative values at all time points (P lt; 0.05); except at 3 days after operation, no significant difference was found in cervical ROM at the other time points when compared with preoperation (P gt; 0.05). Thirteen patients (27.08%) had HO at 4 years after operation, including 8 cases of grade 1, 3 cases of grade 2, and 2 cases of grade 3. There was no significant difference in VAS score, NDI, and cervical ROM between 2 groups at 1, 2, 3, and 4 years (P gt; 0.05). Conclusion The incidence of HO after single-level Bryan cervical artificial disc replacement is relatively high. However, HO has no effect on the cervical ROM and the effectiveness.
ObjectiveTo summarize the design and the biomechanical characteristics of Sivash-range of motion femoral modular stem (S-ROM) prosthesis and mainly to introduce its clinical use in developmental dysplasia of hip (DDH) and hip revision. MethodsLiterature concerning S-ROM prosthesis was extensively reviewed and analyzed. ResultsThe S-ROM prosthesis based on the modularity feature can reach press-fit in metaphysis and diaphysis of femur concurrently. Additionaly, S-ROM prosthesis can fit for anatomic differences of the DDH femur and is capable of use in correction osteotomy and hip revision. ConclusionModular junctions of S-ROM prosthesis increase the potentials of implant fracture and metallic debris production, so further follow-up study is needed to verify the long-term effectiveness.
Objective To evaluate the cl inical outcomes and values of anterior segmental decompression and double-plate fixation (ASDDF) for treatment of ski p cervical spondylotic myelopathy (SCSM). Methods Between June 2005 and June 2008, 17 patients with SCSM were treated with ASDDF. There were 10 males and 7 females with an average age of 58.8 years (range, 41-74 years) and an average disease duration of 9.7 months (range, 6-39 months). According to JapaneseOrthopaedic Association (JOA) score system, 2 patients were rated as extreme severe condition, 7 as severe, 7 as moderate, and 1 as mild. MRI images showed 42 affected cervical disc levels, including 26 disc levels with high-intensity intramedullary lesions on T2, 4 with low-intensity intramedullary lesions on T1, and 12 with significant cord compression but no signal change; according to Nagata classification scale, there were 5 abnormal segments at class I, 21 at class II, and 16 at class III. The rate of fusion, the Cobb angle, and the range of motion (ROM) of the cervical spine were measured preoperatively and postoperatively by the X-ray examinations. The improvement of the neurological function was evaluated by the JOA score. Results The average time of follow-up was 28.6 months (range, 24-58 months). After operation, dysphagia occurred in 2 cases (symptom rel ief after 1 month), hoarseness in 1 case (symptom rel ief after 3 months of methylcobalamin treatment), and degeneration of adjacent segments without symptom in 3 cases. The X-ray films showed the fusion rate of 100% at 12 months after operation without displacement, resorption or collapse of bone graft, and without breakage or loosening of plate and screw. The Cobb angles were (13.3 ± 10.4)° preoperatively, (15.8 ± 10.8)° immediately postoperatively, and (15.4 ± 11.4)° at last follow-up; the ROM of the cervical spine were (41.3 ± 17.4)° preoperatively and (23.8 ± 18.8)° at last follow-up; and the JOA scores were 8.2 ± 2.9 preoperatively, 13.7 ± 3.0 at 12 months postoperatively, and 13.9 ± 2.8 at last follow-up. All indexes showed significant differences between before operation and after operation (P lt; 0.05). The results of JOA scores were excellent in 8 cases, good in 6, fair in 2, and poor in 1 with an average improvement rate of 66.8% (range, 14%-88%) for the neurological function. Conclusion Adequate decompression, high rate of fusion, sol id mechanical stabil ity, improvement of total cervical lordosis,and the neurological function can be achieved through ASDDF for treatment of SCSM.
【Abstract】 Objective To determine the three-dimensional stabil ity of atlantoaxial reconstruction withanterior approach screw fixation through C2 vertebral body to C1 lateral mass and Gall ie’s technique (ASMG) for C1,2instabil ity. Methods Twenty-five human cadaveric specimens (C0-3 ) were divided randomly into 5 groups (n=5). Thethree-dimensional ranges of motion C1 relative to C2 were measured under the five different conditions:the intact state group (group A), type II odontoid fracture group (group B), posterior C1,2 transarticular screw fixation group (group C), ASM group (group D) and ASMG group (group E). The three-dimensional ranges of motions C1 relative to C2 by loading ± 1.5 Nm were measured under the six conditions of flexion/extension, left/right lateral bending, and left/right axial rotation. The obtained data was statistically analyzed. Results In each group, the three-dimensional ranges of motion C1 relative to C2 under the six conditions of flexion/extension, left/right lateral bending, and left/right axial rotation were as follows: in group A (8.10 ± 1.08), (8.49 ± 0.82), (4.79 ± 0.47), (4.93 ± 0.34), (28.20 ± 0.64), (29.30 ± 0.84)°; in group B (13.60 ± 1.25), (13.80 ± 0.77), (9.64 ± 0.53), (9.23 ± 0.41), (34.90 ± 0.93), (34.90 ± 1.30)°; in group C (1.62 ± 0.10), (1.90 ± 0.34), (1.25 ± 0.13), (1.37 ± 0.28), (0.97 ± 0.14), (1.01 ± 0.17)°; in group D (2.03 ± 0.26), (2.34 ± 0.49), (1.54 ± 0.22), (1.53 ± 0.30), (0.80 ± 0.35), (0.76 ± 0.30)°; in group E (0.35 ± 0.12), (0.56 ± 0.34), (0.44 ± 0.15), (0.55 ± 0.16), (0.43 ± 0.07), (0.29 ± 0.06)°. Under the six conditions, there were generally significant differences between group A and other four groups, and between group B and groups C, D and E (P lt; 0.001), and between group E and groups C, D in flexion/ extension and left/right lateral bending (P lt; 0.05). There was no significant difference between group E and groups C, D in left/right axial rotation (P gt; 0.05). Conclusion In vivo biomechanical studies show that ASMG operation has unique superiority in the reconstruction of the atlantoaxial stabil ity, especially in controll ing stabil ity of flexion/extension and left/right lateral bending, and thus it ensures successful fusion of the implanted bone. It is arel iable surgical choice for the treatment of the obsolete instabil ity or dislocation of C1, 2 joint.
A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 N·m to 5 N·m. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.
Objective To summarize the progress of larger flexion gap than extension gap in total knee arthro-plasty (TKA). Methods The domestic and foreign related literature about larger flexion gap than extension gap in TKA, and its impact factors, biomechanical and kinematic features, and clinical results were summarized. Results During TKA, to adjust the relations of flexion gap and extension gap is one of the key factors of successful operation. The biomechanical, kinematic, and clinical researches show that properly larger flexion gap than extension gap can improve both the postoperative knee range of motion and the satisfaction of patients, but does not affect the stability of the knee joint. However, there are also contrary findings. So adjustment of flexion gap and extension gap during TKA is still in dispute. Conclusion Larger flexion gap than extension gap in TKA is a new joint space theory, and long-term clinical efficacy, operation skills, and related complications still need further study.
Objective To evaluate the short-term effectiveness of Kirschner wire (K-wire) elastic fixation in the treatment of Doyle type Ⅰ and Ⅱ mallet finger. Methods Between July 2016 and March 2017, 18 patients with Doyle type Ⅰ and Ⅱ mallet finger were treated. There were 12 males and 6 males, with an average age of 45 years (range, 16-61 years). The index finger was involved in 2 cases, the middle finger in 3 cases, the ring finger in 10 cases, and the little finger in 3 cases. The interval from injury to operation ranged from 2 hours to 45 days (median, 5.5 hours). There were 8 patients of closed wound and 10 patients of open wound. Fourteen patients were simply extensor tendon rupture and 4 were extensor tendon rupture complicated with avulsion fracture. The distal interphalangeal joints (DIPJ) of injured fingers were elastically fixed with the K-wire at mild dorsal extend position. The K-wire was removed after 6 weeks, and the functional training started. Results The operation time was 34-53 minutes (mean, 38.9 minutes). Patients were followed up 3-8 months (mean, 5 months). All incisions healed primarily and no K-wire loosening or infection happened during the period of fixation. All mallet fingers were corrected. The range of motion (ROM) in terms of active flexion of injured DIPJ was (75.83±11.15)° at 6 weeks after operation, showing significant difference when compared with the normal DIPJ of contralateral finger [(85.28±6.06)°] (t=3.158, P=0.003). The ROM in terms of active flexion was (82.67±6.78)° in 15 patients who were followed up at 8 months after operation, showing no significant difference when compared with the normal DIPJ of contralateral finger [(86.00±5.73)°] (t=1.454, P=0.157). After the removal of K-wire at 6 weeks, visual analogue scale (VAS) score of active flexion and of passive flexion to maximum angle were 1.78±0.88 and 3.06±1.06, respectively. According to the total active motion criteria, the effectiveness was rated as excellent in 10 cases, good in 5 cases, moderate in 2 cases, and poor in 1 case, and the excellent and good rate was 83.33%. The patients’ satisfaction were accessed by Likert scale, which were 3-5 (mean, 4.2). Conclusion K-wire elastic fixation in the treatment of Doyle typeⅠand Ⅱ mallet finger can repair the extensor effectively, correct the mallet finger deformity, and also be benefit for the flexion-extension function restoration of DIPJ.
ObjectiveTo summarize research progress of the effect of knee flexion position on postoperative blood loss and knee range of motion (ROM) after total knee arthroplasty (TKA).MethodsThe relevant literature at home and abroad was reviewed and summarized from mechanism, research status, progress, and clinical outcome. The differences of clinical results caused by different positions, flexion angles, and keeping time were compared.ResultsKeeping knee flexion after TKA can reduce postoperative blood loss through the angle change of blood vessels and increase knee early ROM by improving flexion muscle strength. When the flexion angle of the knee is large and the flexion position is keeping for a long time, the postoperative blood loss and the knee ROM can be significantly improved. However, the amount of blood loss and ROM are not further improved in the patients with keeping knee flexion for more than 24 hours compared with less than 24 hours.ConclusionKeeping knee flexion after TKA is a simple and effective method to reduce postoperative blood loss and improve knee ROM. However, the optimal knee flexion angle and time are needed to be further explored.
ObjectiveTo investigate the effectiveness of arthroscopic 360° capsular release for frozen shoulder.MethodsBetween April 2018 and April 2019, 42 patients with frozen shoulders were treated with arthroscopic 360° capsular release. There were 13 males and 29 females, with an average age of 52.3 years (range, 45-56 years). There were 14 left shoulders and 28 right shoulders. The disease duration ranged from 5 to 18 months (mean, 11.1 months). The main clinical symptoms were limited active and passive movement of the shoulder joint with severe pain. All patients excluded impingement syndrome and shoulder osteoarthritis. Preoperative range of motion was as follows: forward flexion (93.2±15.4)°, external rotation at side (15.9±6.0)°, external rotation at 90° abduction (18.4±9.9)°, and internal rotation reaching the greater trochanter in 5 cases, buttocks in 20 cases, S1 level in 17 cases. The visual analogue scale (VAS) score was 6.7±1.7 and the American Society of Shoulder and Elbow Surgery (ASES) score was 41.6±9.3. The active range of motion of shoulder joint, VAS score, and ASES score were recorded during follow-up.ResultsAll incisions healed by first intention, and no early complications occurred. Patients were followed up 12-24 months (mean, 15.6 months). After operation, forward flexion, external rotation at side, and external rotation at 90° abduction significantly improved when compared with preoperatively (P<0.05). The range of internal rotation restored to the level of T6-12 at 3 weeks, which was equivalent to that of the normal side at 12 months after operation (Z=–0.943, P=0.346). VAS scores decreased and ASES scores increased after operation, and the differences between pre- and post-operation were significant (P<0.05); and with time, the VAS scores and ASES scores improved further (P<0.05).ConclusionArthroscopic 360° capsular release can significantly increase the range of motion of the shoulder joint, release pain, and improve function. It is an effective method for the treatment of frozen shoulders.
Objective To compare the effects of cutting and retaining the pes anserinus tendon on effectiveness following tibial plateau fracture. MethodsA clinical data of 40 patients with tibial plateau fracture treated with open reduction and internal fixation with plate via posteromedial approach between January 2015 and January 2020 was retrospectively analyzed, including 18 patients retained the pes anserinus tendon (study group) and 22 patients cut the pes anserinus tendon (control group) during operation. There was no significant difference in gender, age, side of affected knee, cause of injury, Schatzker classification, time from injury to operation, and associated ligament injury between the two groups (P>0.05). The operation time, intraoperative blood loss, hospital stay, anatomic reduction rate, incidence of complications, fracture healing time, knee flexion and extension range of motion at 2 weeks and 12 months, and knee extension range of motion at 3 months after operation were recorded and compared between the two groups. The visual analogue scale (VAS) score was used to evaluate the early postoperative pain improvement at 1, 3, and 14 days after operation and hospital for special surgery (HSS) score was used to evaluate the improvement of knee function at 3, 6, and 12 months after operation. ResultsThe patients in both groups were followed up 12-15 months with an average of 12.8 months. There was no significant difference in operation time, intraoperative blood loss, and fracture healing time between the two groups (P>0.05). The hospital stay in the control group was significantly longer than that in the study group (t=8.339, P=0.000). There was no significant difference in the anatomic reduction rate (90.9% vs. 83.3%) between the control group and the study group (χ2=0.058, P=0.810). There were 1 case of proximal tibial osteomyelitis, 3 cases of skin necrosis, 3 cases of traumatic arthritis, and 2 cases of lower deep venous thrombosis after operation in the control group, and 1 case of metaphyseal nonunion, 2 cases of traumatic arthritis, and 1 case of lower deep venous thrombosis in the study group, showing no significant difference in the incidence of complications (40.9% vs. 22.2%) between the two groups (χ2=1.576, P=0.209). In the study group, knee flexion and extension range of motion at 2 weeks and 12 months and knee extension range of motion at 3 months after operation were significantly better than those of the control group (P<0.05). VAS scores and HSS scores in both groups improved with time after operation (P<0.05), in addition, the HSS score and VAS score of the study group were significantly better than those of the control group (P<0.05). ConclusionCompared with traditional pes anserinus tendon cutting group, pes anserinus tendon retaining group can significantly reduce postoperative short-term pain, improve postoperative knee range of motion and knee function within 1 year after operation.