ObjectiveTo develop an instrument for sacroiliac joint fixation with less injury and less complications. MethodsFirstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups:group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. ResultsAccording to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P>0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than that in group C, but there was no significant difference between group B and group C (P>0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. ConclusionThe polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw direction. The simulated application test shows satisfactory fixing effect.
ObjectiveTo investigate the effectiveness of percutaneous double-segment lengthened sacroiliac screws internal fixation assisted by three-dimensional (3D) navigation technology in treatment of Denis type Ⅱ and Ⅲ sacral fractures. Methods A clinical data of 45 patients with the Denis type Ⅱ and Ⅲ sacral fractures admitted between January 2017 and May 2020 was retrospectively analyzed. There were 31 males and 14 females, with an average age of 48.3 years (range, 30-65 years). The pelvic fractures were all high energy injuries. According to the Tile classification standard, there were 24 cases of type C1, 16 cases of type C2, and 5 cases of type C3. The sacral fractures were classified as Denis type Ⅱ in 31 cases and type Ⅲ in 14 cases. The interval between injury and operation was 5-12 days (mean, 7.5 days). The lengthened sacroiliac screws were implanted in S1 and S2 segments respectively under the assistance of 3D navigation technology. The implantation time of each screw, the intraoperative X-ray exposure time, and the occurrence of surgical complications were recorded. After operation, the imaging reexamination was used to evaluate the screw position according to Gras standard and the reduction quality of sacral fractures according to Matta standard. At last follow-up, the pelvic function was scored with Majeed scoring standard. Results The 101 lengthened sacroiliac screws were implanted with the assisting of 3D navigation technology. The implantation time of each screw was 37.3 minutes on average (range, 30-45 minutes), and the X-ray exposure time was 46.2 seconds on average (range, 40-55 seconds). All patients had no neurovascular or organ injury. All incisions healed by first intention. The quality of fracture reduction was evaluated according to Matta standard as excellent in 22 cases, good in 18 cases, and fair in 5 cases, and the excellent and good rate was 88.89%. The screw position was evaluated according to Gras standard as excellent in 77 screws, good in 22 screws, and poor in 2 screws, and the excellent and good rate was 98.02%. All patients were followed up 12-24 months (mean, 14.6 months). All fractures healed and the healing time was 12-16 weeks (mean, 13.5 weeks). Pelvic function was evaluated according to Majeed scoring standard as excellent in 27 cases, good in 16 cases, fair in 2 cases, and the excellent and good rate was 95.56%. Conclusion Percutaneous double-segment lengthened sacroiliac screws internal fixation for the treatment of Denis type Ⅱ and Ⅲ sacral fractures is minimally invasive and effective. With the assistance of 3D navigation technology, the screw implantation is accurate and safe.