ObjectiveTo evaluate the feasibility and short-term effectiveness of bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach for osteoporotic vertebral compression fracture (OVCF) of lumbar.MethodsA retrospective analysis was made on the clinical data of 93 patients with OVCF of lumbar who met the selection criteria between January 2018 and June 2019. According to the different surgical methods, they were divided into group A (44 cases, treated with bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach) and group B [49 cases, treated with percutaneous kyphoplasty (PKP) via bilateral transpedicle approach]. There was no significant difference in gender, age, body mass index, T value of bone mineral density, injury cause, fractured level, time from injury to operation, comorbidities, and preoperative Cobb angle of injured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) between the two groups (P>0.05). The operation time, intraoperative fluoroscopy times, bone cement injection amount, and incidence of bone cement leakage were recorded and compared between the two groups; Cobb angle of the injured vertebrae, VAS score, and ODI were measured before operation, at 2 days and 1 year after operation. The contralateral distribution ratio of bone cement was calculated according to the anteroposterior X-ray film at 2 days after operation.ResultsThe operation time and the intraoperative fluoroscopy times in group A were significantly less than those in group B (P<0.05). There was no bone cement adverse reactions, cardiac and cerebrovascular adverse events, and no complications such as puncture needles erroneously inserted into the spinal canal and nerve injuries occurred in the two groups. Bone cement leakage occurred in 6 cases and 8 cases in groups A and B, respectively, all of which were asymptomatic paravertebral or intervertebral leakage, and no intraspinal leakage occurred; the bone cement injection amount and incidence of bone cement leakage between the two groups showed no significant differences (P>0.05). The contralateral distribution ratio of bone cement in group A was significantly lower than that in group B (t=2.685, P=0.009). Patients in both groups were followed up 12-20 months, with an average of 15.3 months. The Cobb angle of the injured vertebrae, VAS score, and ODI in the two groups were significantly improved at 2 days after operation, however, the Cobb angle of the injured vertebra at 1 year after operation was significantly lost when compared with the 2 days after operation, the VAS score and ODI at 1 year after operation were significantly further improved when compared with the 2 days after operation, the differences were all significant (P<0.05). There was no significant difference in the Cobb angle of the injured vertebrae, VAS score, and ODI between the two groups at each time point after operation (P>0.05).ConclusionBilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach is comparable to bilateral PKP in short-term effectiveness with regard to fracture reduction, reduction maintenance, pain relief, and functional improvement. It has great advantages in reducing operation time and radiation exposure, although it is inferior in bone cement distribution.
Objective To evaluate the deviation between actual and simulated screw placement after cervical pedicle screw placement assisted by 3D printed navigation template, and analyze the correlation between screw placement deviation and navigation pipe length. Methods A total of 40 patients undergoing cervical 1-7 pedicle screw insertion assisted by 3D printed navigation template in Zigong Fourth People’s Hospital between February 2018 and August 2020 were included in this prospective study. These patients were divided into 3 groups randomly, including 12 patients with a 5-mm pipe length (5 mm group), 13 patients with a 10-mm pipe length (10 mm group), and 15 patients with a 15-mm pipe length (15 mm group). Three-dimensional modeling was performed on preoperative cervical CT images of these patients and simulated pedicle screw was placed. Individualized pedicle screw navigation templates were designed according to the position and direction of simulated pedicle screws, and 3D printing was performed on the cervical model and navigation templates. Preoperative 3D printed model and navigation templates were used to simulate the surgical process to confirm the safety of screws. During the operation, pedicle screw placement was performed according to the preoperative design and simulated surgical process. The postoperative CT images were registered with the preoperative CT images in 3D model. The safety of screw placement was evaluated by the postoperative screw placement Grade, and the accuracy of screw placement was evaluated by measuring the deviation of screw placement point and the deviation of screw placement direction in horizontal plane (inclination angle) and sagittal plane (head inclination angle). The influence of different navigation pipe lengths on the safety and accuracy of screw placement was analyzed. Results A total of 164 pedicle screws were inserted with navigation template assistance, including 48 screws (38 in Grade 0 and 10 in Grade 1) in the 5 mm group, 52 screws in the 10 mm group (all in Grade 0), and 64 screws (52 in Grade 0 and 12 in Grade 1) in the 15 mm group, and the difference in the grade among the three groups was statistically significant (P<0.05). When the navigation pipe length was 5, 10, and 15 mm, respectively, the screw entry point deviation was (1.87±0.63), (1.44±0.63), and (1.66±0.54) mm, respectively, the inclination angle deviation was (2.72±0.25), (0.90±0.21), and (1.84±0.35)°, respectively, and the head inclination angle deviation was (8.63±1.83), (7.15±1.38), and (8.24±1.52)°, respectively. The deviations in the 10 mm group were all significantly less than those in the other two groups (P<0.05). Conclusions In the cervical pedicle screw placement assisted by navigation template, all the screws were Grade 0 or Grade 1, with high safety. The mean deviation of the screw entry point is within 2 mm, with high accuracy. When the length of navigation pipe is 10 mm, the safety and accuracy of screw placement can be fully guaranteed.
Thoracolumbar injury is a common injury in clinic. Accurate diagnosis and classification is of great significance for guiding treatment. Although there are many typing systems, no typing system has been widely accepted and used to guide clinical practice. Denis classification, spinal load classification, thoracolumbar injury classification system and severity score or thoracolumbar injury classification and severity score and AO classification have great influence in clinical practice, but they all have some shortcomings. In recent years, the classification of thoracolumbar injury has been updated, modified and supplemented constantly. When using these fracture types in clinical practice, different people often have some deviation. This paper reviews the widely used thoracolumbar injury classification system, discusses the main viewpoints, advantages and disadvantages of each classification system, and looks into the future research direction based on the current research progress.
Objective To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study. Methods Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T12 in 15 cases, L1 in 20 cases, L2 in 19 cases, and L3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded. Results In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant (P<0.05). Conclusion UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.