west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "tension band" 6 results
  • A BIOMECHANICAL STUDY ON INTERNAL FIXATION OF PROXIMAL ULNA COMBINED WITH OLECRANON FRACTURE

    Objective To compare the biomechanical stability of Kirschner wire and tension band wiring, reconstruction plate combined with tension band wiring, and olecranon anatomical plate in fixing proximal ulna combined with olecranon fracture, so as to provide the theoretical evidence for clinical selection of internal fixation. Methods Eight specimens of elbow joints and ligaments were taken from eight fresh male adult cadaveric elbows (aged 26-43 years, mean 34.8 years) donated voluntarily. The model of proximal ulna combined with olecranon fracture was made by an osteotomy in each specimen. Fracture end was fixed successively by Kirschner wire and tension band wiring (group A), reconstruction plate combined with tension band wiring (group B), and olecranon anatomical plate (group C), respectively. The biomechanical test was performed for monopodium compression experiments, and load-displacement curves were obtained. The stability of the fixation was evaluated according to the load value when the compression displacement of fracture segment was 2 mm. Results No Kirschner wire withdrawal, broken plate and screw, loosening and specimens destruction were observed. The load-displacement curves of 3 groups showed that the displacement increased gradually with increasing load, while the curve slope of groups B and C was significantly higher than that of group A. When the compression displacement was 2 mm, the load values of groups A, B, and C were (218.6 ± 66.9), (560.3 ± 116.1), and (577.2 ± 137.6) N, respectively; the load values of groups B and C were significantly higher than that of group A (P lt; 0.05), but no significant difference was observed between groups B and C (t=0.305, P=0.763). Conclusion The proximal ulna combined with olecranon fracture is unstable. Reconstruction plate combined with tension band wiring and olecranon anatomical plate can meet the requirement of fracture fixation, so they are favorable options for proximal ulna combined with olecranon fracture. Kirschner wire and tension band wiring is not a stable fixation, therefore, it should not be only used for proximal ulna combined with olecranon fracture.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • TREATMENT OF ULNAR COLLATERAL LIGAMENT AVULSION FRACTURE OF THUMB METACARP-OPHALANGEAL JOINT USING A COMBINATION OF Kirschner WIRE AND SILK TENSION BAND

    Objective To investigate the effectiveness of Kirschner wire combined with silk tension band in the treatment of ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint. Methods Between September 2008 and October 2011, 14 patients with ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint were treated using a combination of Kirschner wire and silk tension band. There were 8 males and 6 females, aged 23-55 years (mean, 40.8 years). The causes of injury were machinery twist injury in 5 cases, manual twist injury in 4 cases, falling in 4 cases, sports injury in 1 case. The time from injury to operation was 2 hours-14 days. All the patients presented pain over the ulnar aspect of the metacarpophalangeal joint of the thumb, limitation of motion, and joint instability with pinch and grip. The lateral stress testing of the metacarpophalangeal joint was positive. Function training was given at 2 weeks after operation. Results All incisions healed by first intention. The lateral stress testing of the metacarpophalangeal joint was negative. All the patients were followed up 6-18 months (mean, 13.1 months). The X-ray films showed good fracture reduction and healing with an average time of 7 weeks (range, 4-10 weeks). At last follow-up, the thumbs had stable flexion and extension of the metacarpophalangeal joint, normal opposition function and grip and pinch strengths. According to Saetta et al. criteria for functional assessment, the results were excellent in 11 cases and good in 3 cases; the excellent and good rate was 100%. Conclusion It is an easy and simple method to treat ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint using Kirschner wire combined with silk tension band, which can meet the good finger function.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • Effectiveness of cerclage and a figure-of-eight tension band by a single titanium wire in treatment of patellar fracture

    ObjectiveTo estimate the outcome of cerclage followed by a figure-of-eight tension band with a single titanium wire for the treatment of patellar fracture.MethodsA retrospective analysis was made on the clinical data of 46 patients with patellar fractures treated between June 2012 and November 2014. There were 30 males and 16 females, aged 20-86 years (mean, 54 years). The fracture causes included falling in 27 cases, traffic accident in 16 cases, and knock in 3 cases. There were 41 cases of closed fractures and 5 cases of open fracture. The injury located at the left side in 24 cases and the right side in 22 cases. According to AO classification, fracture was rated as type 34-A in 3 cases, as type 34-B in 1 case, as type 34-C1 in 7 cases, as type 34-C2 in 13 cases, and as type 34-C3 in 22 cases. The time between injury and operation ranged 1-12 days (mean, 3.7 days). During operations, a single titanium wire was used to pass around the patellar, followed a figure-of-eight wrapping, to tight and fix at the tension of 35 kg.ResultsAll incisions healed primarily. The patients were followed up 20.6 months on average (range, 6-24 months). Partial wire loosening was found in 2 cases, irritation of skin or soft tissue in 1 case. The X-ray examination showed bony healing at 3 months after operation, without breakage of titanium wire. The internal fixation was removed in 38 cases at 12 months after operation. According to the Böstman rating score, the mean score was 28.34 (range, 24-30) at 12 months after ope-ration; the results were excellent in 42 cases and good in 4 cases, with an excellent and good rate of 100%.ConclusionFor patellar fracture, cerclage followed by a figure-of-eight tension band with a single titanium wire is able to achieve an effective stability and to allow early motion for patient with less complication.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Indirect reduction technique via Nice knot for transverse fracture of patella

    ObjectiveTo assess the outcomes in indirect reduction technique via Nice knot for transverse patellar fractures.MethodsThe clinical data of 25 patients with transverse patellar fractures meeting the inclusion criteria between January 2017 and December 2018 were retrospectively analyzed. The patients were divided into trial group (n=13) and control group (n=12) according to different intraoperative reduction methods. No significant difference was found in gender, age, affected side, cause of fracture, classification, or the time from injury to operation between the two groups (P>0.05). In the trial group, No.2 suture was used to cross the quadriceps tendon and patellar tendon to construct the Nice knot, then the suture was tightened to make the distal and proximal fracture segments contact in an indirect reduction pattern. Depend on Nice knot’s sliding compression and self-stabilizing function, the suture mesh created an anterior tension band as a temporary fixation. In the control group, Weber’s clamp was used to hold the fracture segments directly and fixed temporarily. After reduction, terminal fixation was conducted using a titanium Kirschner wire with titanium cable in both groups. The operation time, intraoperative blood loss, follow-up time, fracture healing time, and complications were recorded and compared in the two groups. At last follow-up, the knee function was evaluated according to the Böstman scoring criteria for efficacy in patellar fractures.ResultsThe operation time in the trial group was significantly shorter than that in the control group (t=−2.165, P=0.041). There was no significant difference of intraoperative blood loss between the two groups (t=0.514, P=0.612). The incisions of the two groups healed by first intention. All the patients were followed up 12-16 months, with an average of 14.4 months, no significant difference was found in the follow-up time between the two groups (t=−0.309, P=0.760). One patient in the control group developed soft tissue irritation symptoms at 1 day after operation, and no special treatment was given, the symptoms disappeared at 2 months after operation. The fractures of the two groups healed at the 12-week follow-up. During the follow-up, there was no complication such as loosening and fracture of titanium cables and tendon tissue calcification. At last follow-up, the Böstman score presented no significant difference between the two groups (t=−0.086, P=0.932). In the trial group, an 80-year-old female patient was evaluated as good (score, 27) due to atrophy of the quadriceps femoris, leg weakness, and affected stair climbing, and the rest 24 patients were all evaluated as excellent.ConclusionThe indirect reduction with Nice knot can shorten the operation time in the treatment of transverse patellar fractures, and obtain good effectiveness.

    Release date:2021-06-30 03:55 Export PDF Favorites Scan
  • Comparative study on the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures

    ObjectiveTo compare the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures.MethodsBetween January 2017 and January 2019, 26 patients with type C patellar fractures were treated with improved Kirschner wire tension band fixation (group A), and 24 patients were treated with traditional Kirschner wire tension band fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, and side and type of fracture between 2 groups (P>0.05). The operation time, intraoperative blood loss, the visual analogue scale (VAS) scores at 1 and 3 days after operation, the fracture healing time, and the occurrence of complications (skin irritation of Kirschner wires, failure of internal fixation, fracture reduction loss) were recorded, and the knee function was evaluated by Lysholm scoring standard in 2 groups.ResultsThe operation time in group A was significantly less than that in group B (t=−4.742, P=0.000). There was no significant difference in the intraoperative blood loss and VAS scores at 1 and 3 days after operation between 2 groups (P>0.05). All incisions healed by first intention. All patients were followed up 8-15 months, with an average of 11 months. The fracture healing time was (3.3±0.6) months in group A and (3.2±0.6) months in group B, showing no significant difference (t=0.589, P=0.559). At last follow-up, the knee joint function was evaluated according to Lysholm scoring standard. And there were 15 cases of excellent, 8 cases of good, and 3 cases of fair, with an excellent and good rate of 88.5% in group A; there were 8 cases of excellent, 7 cases of good, 7 cases of fair, and 2 cases of poor, with an excellent and good rate was 62.5%. The difference between 2 groups was significant (Z=2.828, P=0.005). The internal fixators were removed after the fracture healed in 2 groups. At last follow-up, no skin irritation of Kirschner wires occurred in group A, but 3 cases in group B. X-ray films reexamination showed that 5 cases of internal fixation failure and no fracture reduction loss were found in group A, while 9 cases of internal fixation failure and 1 case of fracture reduction loss in group B. The incidence of complications in group A was 19.2% (5/26), which was significantly lower than that in group B (54.2%, 13/24) (χ2=6.611, P=0.010).ConclusionCompared with the traditional Kirschner wire tension band fixation, the improved Kirschner wire tension band fixation in treatment of type C patellar fracture can shorten the operation time, reduce the incidence of complications, and benefit the functional recovery of knee joint.

    Release date: Export PDF Favorites Scan
  • Effectiveness of transverse double “8”-shaped tension band technique for Lawrence zoneⅠ fracture of the fifth metatarsal base

    Objective To explore the effectiveness of transverse double “8”-shaped tension band technique in the treatment of Lawrence zoneⅠfracture of the 5th metatarsal base. Methods Between February 2019 and October 2021, 15 patients with Lawrence zoneⅠfracture of the 5th metatarsal base were treated with transverse double “8”-shaped tension band technique. There were 8 males and 7 females, with a median age of 40 years (range, 23-59 years). The fractures were caused by sprains. The time from injury to operation was 3-7 days (mean, 4.1 days). X-ray films were taken to observe the fracture healing and the anchor looseness and detachment. The foot function was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS) score, and the eversion angle of the calcaneal talus joint. Results The incisions healed by first intention after operation in 14 cases and the incision healed poorly in 1 case. All patients were followed up 8-12 months (median, 10 months). The imaging examination showed that all fractures healed well, with a healing time of 10-14 weeks (mean, 11.7 weeks). At last follow-up, AOFAS score was 82-100 (median, 98); 13 cases were excellent and 2 cases were good, with an excellent and good rate of 100%. VAS score was 0-3 (median, 1). Three cases had mild limited ankle joint range of motion, while 12 cases had normal range of motion. The eversion angle of the calcaneal talus joint was 25°-32° (median, 30°). Conclusion The application of transverse double “8”-shaped tension band technique for Lawrence zone Ⅰ fracture of the 5th metatarsal base has advantages such as simple operation, avoidance of secondary operation, and reduction of foreign body sensation, with definite effectiveness.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content