west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "ultrasonic" 17 results
  • CONTROL STUDY OF INFRA-RED LIGHT SCANNING AND COLORED ULTRASONIC DOPPLER IN DIAGNOSIS OF BREAST MASSES

    【Abstract】Objective To estimate the value of the infra-red light scanning and the colored ultrasonic Doppler in diagnosis of breast masses. Methods Two hundred and seventy nine patients with breast mass were examined with the infrared light scanning and the colored ultrasonic Doppler in our hospital.Following the two examinations the masses were resected and pathologically examined as a control. Results The conformity of the infra-red light scanning with pathologic diagnosis was 94.0% in 182 hyperplasia masses, while that of the ultrasonic Doppler was 84.6%(P<0.01). The conformity of the infra-red light scanning with pathology was 91.7% and that of the colored ultrasonic Doppler was 83.3%(Pgt;0.05). The colored ultrasonic Doppler was seemingly more effective than infrared light scanning in diagnosing 9 galactocele and 5 intraductal papilloma, but there is no significant difference(Pgt;0.05). The conformity of the two exams with pathology in 59 fibroadenoma was almost the same.Conclusion The infra-red light scanning is more effective than the colored ultrasonic Doppler in diagnosing the hyperplasia masses, there is no significant difference in diagnosing the breast cancer and the fibroadenoma between the two exams. Combined use of this two exams would increase the accurase of the breast masses.

    Release date:2016-08-28 05:30 Export PDF Favorites Scan
  • Development and Design of a New Sonography Rigid Bronchoscopy and Corollary Vacuum-assisted Biopsy Device System

    The present study was to develop and design a new sonography rigid bronchoscopy and corollary vacuum-assisted biopsy device system with less injury and complication. The system combined ultrasonic-probe with ultrasound catheter, a new medical ultrasound technique, and rigid bronchoscopy (RB) which is improved with an auxiliary vacuum-assisted biopsy device. The principle of the device is vacuum suction and rotary knife. The reduced outer diameter of the RB led to less pain and lower complications for the patient. With the help of ultrasonic-probe (30 MHz), lesions and blood vessels can be identified clearly and unintentional puncture and damage to blood vessels can be avoided. Plenty of lesions can be obtained quickly through the vacuum-assisted biopsy device without getting puncture needle in and out repeatedly. The novel endobronchial sonography rigid bronchoscopy and matched vacuum-assisted biopsy device has many remarkable advantages. It can enlarge the applied range of the RB from endobronchial to mediastinal lesions, avoiding unintentional puncture of vessels. Obtaining multiple samples with a higher accuracy rate than that by other sampling techniques, minimizing operation time, alleviating pain and decreasing the complication rate, the system makes up the technical deficiency for the diagnosis and treatment of the mediastinal lesions, to a certain degree.

    Release date: Export PDF Favorites Scan
  • Effect of Hemorheology on Ultrasonic Doppler Blood Flow Spectrum Diagram

    The present research aims to point out the long-existing defect of analyzing the spectrum diagram only from the perspective of haemodynamics instead of haemorheology. In the light of the theories of haemodynamics and haemorheology, the causes of spectrum diagram formation of carotid artery blood at the rapid and slow flow can be clarified completely and accurately. Four conclusions have been drawn in the end. As long as the velocity gradient is large enough, obvious red blood cells concentrate to the shaft even in the big or bigger blood vessels; the spectrum diagram is the powerful proof of the two phase flow model of blood; the spectrum diagram can be completely and accurately analyzed only by combining haemodynamics with haemorheology; and only when the red blood cells concentrate to the shaft, the big or bigger blood vessels can be regarded as haemogeneous fluid.

    Release date: Export PDF Favorites Scan
  • Measurement Method of Arterial Shear Stress of Rats Model Based on Ultrasonic Particle Imaging Velocimetry

    The development and progression of atherosclerosis and thrombosis are closely related to changes of hemodynamics parameters. Ultrasonic pulse wave Doppler technique is normally used for noninvasively blood flow imaging. However, this technique only provides one-dimensional velocity and depends on the angle between the ultrasound beam and the local velocity vector. In this study, ultrasonic particle image velocimetry method was used to assess whole field hemodynamic changes in normal blood vessels. By using the polynomial fitting method, we investigated the velocity gradient and assessed the shear in different blood flow velocity of 10 healthy rats. It was found that using four polynomial fitting could result in optimal measurement results. The results obtained by ultrasonic particle image velocimetry accorded with the results obtained using Doppler technique. The statistical average of cyclical vessel wall shear stress was positively related to the locational mean velocity. It is proven that ultrasonic particle image velocimetry method could be used to assess directly the real-time whole field hemodynamic changes in blood vessels and was non-invasively, and should be a good prosperous technique for monitoring complex blood flow in stenotic arteries.

    Release date: Export PDF Favorites Scan
  • Research on Visualization of Ultrasonic Rhinitis Therapeutic Apparatus Based on V4L2

    This paper reports the study and design of a visualization system of the ultrasonic rhinitis therapeutic apparatus with the function of endoscopic sinus. On Linux operating platform, we captured the video data of a video capture card that connected the endoscopic sinus using Video4Linux (V4L2) that was provided by the operating system. The video images were displayed by Qt. The visualization system solved the problem that the current ultrasonic rhinitis therapeutic apparatus had to rely on the large and expensive endoscopy equipment. And this simplified the doctors' operation, met the need of monitoring nasal cavity in the process of operating, greatly reduced the costs of treatment and would contribute to the promotion of the instrument. As a result, it has been tested that the nasal endoscopic image achieved by the system is clear and smooth, and fully meet the clinical needs of ultrasonic treatment of rhinitis.

    Release date: Export PDF Favorites Scan
  • The imaging diagnosis of pancreatic cancer: recent advances

    Objective To summary the recent progression of imaging methods which mainly applied on the early detection and qualitative diagnosis of pancreatic cancer. Method The newest related literatures between home and abroad were collected and reviewed. Results Ultrasonic, computed tomography, magnetic resonance imaging and positron emission tomography mostly be used on pancreatic cancer detection and diagnosis. Conclusion Each method gets its own advantage even computed tomography seems like dominated on the detection and diagnosis pancreatic cancer, moreover, magnetic resonance imaging has been improved rapidly in recent years which shows its enormous potential.

    Release date:2017-04-18 03:08 Export PDF Favorites Scan
  • Application of ultrasonic bone curette in posterior cervical single open-door laminoplasty

    Objective To investigate the safety and reliability of ultrasonic bone curette in posterior cervical single open-door laminoplasty. Methods The clinical data were retrospectively analyzed, from 193 patients who underwent single open-door laminoplasty (C 3–7) from January 2012 to January 2016. The patients were divided into three groups according to different instruments: posterior single open-door laminoplasty was performed with ultrasonic bone curette in 61 cases (group A), with bite forceps in 73 cases (group B), and with micro-grinding drill in 59 cases (group C). There was no significant difference in gender, age, the course of disease, underlying disease and preoperative Japanese Orthopedic Association (JOA) score, visual analogue scale (VAS) between groups (P>0.05). The operative time, intraoperative blood loss, drainage volume at 48 hours, JOA score, improvement rate, VAS and perioperative com-plication were compared. Results The operative time, intraoperative blood loss, and drainage volume at 48 hours of group A were significantly less than those in groups B and C (P<0.05), but there was no significant between groups B and C (P>0.05). The follow-up time was 12-21 months (mean, 14.6 months) in group A, 24-36 months (mean, 27.5 months) in group B, and 28-47 months (mean, 38.1 months) in group C. There were no cerebrospinal fluid leakage and incision infection in three groups. No complications of internal fixation loosening and rupture occurred during the follow-up. Rediating pain occurred in 6 cases of group A, 8 cases of group B, and 6 cases of group C, and was cured at 1 week after dehydration and physical therapy. No nerve root palsy was found in three groups. Fracture of portal axis occurred in 5 cases (7 segments) of group B and was fixed by micro titanium plate. The JOA score and VAS score at last follow-up were significantly improved when compared with preoperative scores in three groups (P<0.05); there was no significant difference in JOA score and improvement rate and VAS score between groups (P>0.05). Conclusion It is safe and reliable to use the ultrasonic bone curette in posterior cervical single open-door laminoplasty. It can shorten the operative time and has similar clinical curative effect to the traditional operation, and the lateral rotation of the lamina can be avoided.

    Release date:2017-06-15 10:04 Export PDF Favorites Scan
  • Application of thyroidectomy by meticulous capsular dissection technique through neck incision approach in treatment of 75 patients with type Ⅰ substernal goiter

    Objective To assess clinical value of thyroidectomy by meticulous capsular dissection technique through neck incision approach in treatment of 75 patients with type Ⅰ substernal goiter. Methods The clinical data of 75 patients with type Ⅰ substernal goiter in the Department of General Surgery of the Central Hospital of Xiaogan from April 2013 to April 2017 were retrospectively analyzed. These patients received the surgical resection by the meticulous capsular dissection technique with an ultrasonic scalpel and a bipolar coagulation forcep through neck incision approach. Results There were 12 Hashimoto thyroiditis, 10 thyroid adenoma, 41 nodular goiter, and 12 thyroid carcinoma in the 75 patients with type Ⅰ substernal goiter. Five cases underwent the unilateral total thyroidectomy. Fifty-eight cases underwent the bilateral total thyroidectomy. The bilateral total thyroidectomy plus central lymph node dissection were performed in the 9 patients with thyroid carcinoma, the bilateral total thyroidectomy plus central lymph node dissection plus affected ipsilateral neck lymph node dissection were performed in the 3 patients with thyroid carcinoma. The average operative time was 100 min, the average intraoperative blood loss was 50 mL, the average postoperative hospital stay was 5 d. The rate of parathyroid injury was 2.7% (2/75), the rate of hypocalcemia caused by parathyroid injury was 2.7% (2/75). There were 3 cases (4.0%) of unilateral recurrent laryngeal nerve injury, 1 case (1.3%) of the outer branch of the upper laryngeal nerve injury. There were 2 cases of tracheal partial softening in the 75 patients. None of postoperative bleeding and seroma happened. No death and the tumor recurrence and metastasis of patients happened during follow-up period. Conclusions Preliminary results in this study show that operation of meticulous capsular dissection technique with an ultrasonic scalpel and a bipolar coagulation forcep through neck incision approach in treatment of type Ⅰ substernal goiter is safe and feasible, it could effectively reduce postoperative complications of thyroidectomy, and protect parathyroid and it’s function, recurrent laryngeal nerve, and superior laryngeal nerve.

    Release date:2018-02-05 01:53 Export PDF Favorites Scan
  • Risk assessment of thyroid papillary carcinoma with ultrasound

    ObjectiveTo evaluate the value of preoperative risk assessment of papillary thyroid carcinoma with ultrasound for clinic diagnosis and treatment.MethodsThe data of 400 patients with papillary thyroid carcinoma received operative treatment in 2017 were retrospectively analyzed. Recorded and analyzed the ultrasonic risk assessment and postoperative grading of clinic risk assessment, to evaluate coherence and correlation between them.ResultsThere were 400 lesions with an average size of (12.8±8.5) mm. Among 400 lesions, diameter of 214 lesions less than 10 mm, diameter of 178 lesions were between 10 mm and 40 mm, and diameter of 8 lesions were larger than 40 mm. A total of 242 cases had lymph node metastasis and 309 cases had capsule invasion. Clinical and ultrasoud risk assessment was performed on 400 lesions. There were 224 lesions with low risk of clinical risk stratification vs. 111 lesions with low ultrasonic risk, 148 lesions with intermediate risk of clinical risk stratification vs. 270 lesions with intermediate ultrasonic risk, and 28 lesions with high risk of clinical risk stratification vs. 19 lesions with high ultrasonic risk. The consistency of postoperative recurrence risk stratification and preoperative ultrasound recurrence risk stratification was moderate (κ=0.414, P<0.01). In addition, the consistency between ultrasound examination and clinical lymph node metastasis was poor (κ=0.291, P<0.05), and the consistency of invasion of the capsule was moderate (κ=0.402, P<0.05).ConclusionPre- operative evaluation of recurrence risk grading before thyroid ultrasound, focusing on individualized preoperative assessment, the assessment is more detailed and detailed, and is helpful for follow-up treatment and early screening for recurrence risk.

    Release date:2018-12-13 02:01 Export PDF Favorites Scan
  • A preliminary study of the hemodynamics of concealed perforator flap in animal model with ultrasonic Doppler technique

    Objective To study the hemodynamic characteristics of concealed perforator flap in mini-pigs by ultrasonic Doppler technique. Methods Seven 7-month-old mini-pigs, weighing 20-25 kg, were included in the study. The saphenous artery perforator flap (group A, n=4), saphenous artery concealed perforator flap (group B, n=5), and saphenous artery concealed perforator flap combined with sarcolemma (group C, n=5) models were established randomly on both hind limbs of pigs. The pigs and flap survival conditions were observed after operation. The percentage of flap survival area was calculated by Photoshop CS5 software at 5 days after operation. Ultrasonic Doppler technique was performed on the flaps before operation and at immediate, 3 days, and 5 days after operation to record the hemodynamic changes of the flaps. The hemodynamic indicators of saphenous artery (inner diameter, peak systoli velocity, resistance index, and blood flow) and saphenous vein (inner diameter, maximum velocity, and blood flow) were recorded. Results At 1 day after operation, 1 pig died of infection, and the rest survived until the experiment was completed. Finally, the 3 flaps of group A, 4 of group B, and 5 of group C were included in the study. The flaps of the 3 groups all showed swelling after operation, which was most significant at 3 days. At 3 days after operation, the flaps in group B showed partial bruising and necrosis. At 5 days after operation, the flaps in groups A and C were basically alive, and the necrosis area of flap in group B increased further. The percentage of flap survival area in groups A, B, and C were 99.7%±0.5%, 74.8%±26.4%, and 100%, respectively. The percentage of flap was significantly lower in group B than in groups A and C (P<0.05). There was no significant difference between groups A and C (P>0.05). There were significant differences in the hemodynamic indicators of saphenous artery and vein between different time points in 3 groups (P<0.05). There was no significant difference in each indicator between groups at each time point (P>0.05). Conclusion Both the saphenous artery concealed perforator flap and the flap combined with sarcolemma have stable blood flow, but the survival area of the latter was better than the former.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content