west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "vertebral arch-transverse pathway" 1 results
  • Clinical application of vertebral arch-transverse pathway in pedicle screw implantation

    ObjectiveTo investigate the safety and effectiveness of pedicle screw implantation via vertebral arch-transverse pathway in clinical application by a prospective randomized controlled trial.MethodsTwenty-four patients who were admitted between May 2015 and June 2017 and met the selection criteria for thoracic pedicle screw fixation were included in the study. According to the random number table method, they were divided into the trial group (screw implantation via vertebral arch-transverse pathway) and the control group (traditional screw implantation technology), with 12 patients in each group. There was no significant difference between the two groups in age, gender, cause of injury, injured segment, and the interval between injury and operation (P>0.05). The time of screw implantation was recorded and compared between the two groups. The acceptable rate of screw implantation and the penetration rate of pedicle wall were calculated after operation.ResultsThe time of screw implantation of trial group was (5.08±1.74) minutes, which was significantly shorter than that of control group [(5.92±1.66) minutes], and the difference was significant (t=4.258, P=0.023). Patients in both groups were followed up 1-2 years, with an average of 1.5 years. During the follow-up, no failure of internal fixation occurred. At 1 week after operation, the screw implantation in trial group was rated as gradeⅠin 54 screws, gradeⅡ in 3 screws, and grade Ⅲ in 2 screws, with the acceptable rate of 93.61%. The screw implantation in control group was rated as gradeⅠin 40 screws, grade Ⅱin 10 screws, grade Ⅲ in 8 screws, and grade Ⅳ in 1 screw, with the acceptable rate of 84.75%. There was significant difference in the acceptable rate of screw implantation between the two groups (χ2=3.875, P=0.037). The penetration rate of pedicle wall in trial group was 8.47% (5/59), which was significantly lower than that in the control group [32.20% (19/59); χ2=4.125, P=0.021].ConclusionCompared with the traditional technique, the pedicle screw implantation via vertebral arch-transverse pathway can obtain a good position of the screw canal with higher accuracy and simpler operation.

    Release date:2019-12-23 09:44 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content