Generally, P-wave is the wave of low-frequency and low-amplitude, and it could be affected by baseline drift, electromyography (EMG) interference and other noises easily. Not every heart beat contains the P-wave, and it is also a major problem to determine the P-wave exist or not in a heart beat. In order to solve the limitation of suiting the diverse morphological P-wave using wavelet-amplitude-transform algorithm and the limitation of selecting the pseudo-P-wave sample using the wavelet transform and neural network, we presented new P-wave detecting method based on wave-amplitude threshold and using the multi-feature as the input of neural networks. Firstly, we removed the noise of ECG through the wavelet transform, then determined the position of the candidate P-wave by calculating modulus maxima of the wavelet transform, and then determine the P-wave exist or not by wave-amplitude threshold method initially. Finally we determined whether the P-wave existed or not by the neural networks. The method is validated based on the QT database which is supplied with manual labels made by physicians. We compared the detection effect of ECG P-waves, which was obtained with the method developed in the study, with the algorithm of wavelet threshold value and the method based on "wavelet-amplitude-slope", and verified the feasibility of the proposed algorithm. The detected ECG signal, which is recorded in the hospital ECG division, was consistent with the doctor's labels. Furthermore, after detecting the 13 sets of ECG which were 15min long, the detection rate for the correct P-wave is 99.911%.
Due to the characteristics and environmental factors, electrocardiogram (ECG) signals are usually interfered by noises in the course of signal acquisition, so it is crucial for ECG intelligent analysis to eliminate noises in ECG signals. On the basis of wavelet transform, threshold parameters were improved and a more appropriate threshold expression was proposed. The discrete wavelet coefficients were processed using the improved threshold parameters, the accurate wavelet coefficients without noises were gained through inverse discrete wavelet transform, and then more original signal coefficients could be preserved. MIT-BIH arrythmia database was used to validate the method. Simulation results showed that the improved method could achieve better denoising effect than the traditional ones.
The study of neuronal activity with low frequency has shown an increasing interest for its greater stability and reliability recent years. One challenge in analyzing this kind of activity is to find similarities and differences between signals efficiently and effectively. The traditional analysis methods, such as short-time Fourier transform, are easily obscured by background noises and often involve a large number of parameters. Therefore, this paper introduces a novel time-frequency analysis method based on wavelet transformation and half-ellipsoid modeling to extract instantaneous frequency and instantaneous phase information. This method overcomes some shortcomings of conventional time-frequency analysis. In this method, wavelet transformation is used to provide high-level representations of raw signals, and parsimonious half-ellipsoid models are used to extract changes in time domain and frequency domain of neural recordings. The method was validated to local field potentials (LFPs) of olfactory bulb of anesthetized rats during three different odor stimuli. The results suggested that this method could detect odor-relevant features from olfactory signals with large variability. The Odors then were classified with support vector machine (SVM) algorithm and the classification accuracy reached 79.4%.
To solve the problems of noise interference and edge signal weakness for the existing medical image, we used two-dimensional wavelet transform to process medical images. Combined the directivity of the image edges and the correlation of the wavelet coefficients, we proposed a medical image processing algorithm based on wavelet characteristics and edge blur detection. This algorithm improved noise reduction capabilities and the edge effect due to wavelet transformation and edge blur detection. The experimental results showed that directional correlation improved edge based on wavelet transform fuzzy algorithm could effectively reduce the noise signal in the medical image and save the image edge signal. It has the advantage of the high-definition and de-noising ability.
In this work, a new method of heart sound signal preprocessing is presented. First, the heart sound signals are decomposed by using multilayer wavelet transform. And then double parameters as thresholds are used in processing each layer after decomposition for denoising. Next, reconstruction of heart sound signals could be done after processing last layer. Four methods, i.e. wavelet transform, Hilbert-Huang transform (HHT), mathematical morphology, and normalized average Shannon energy, were used to extract the envelop of the heart sound signals respectively after reconstruction of heart sounds. All methods were improved in this study. We finally in our study chose 30 cases of raw heart sound signals, which were selected randomly from a database comed from The Clinical Medicine Institute of Montreal, and processed them by using the improved methods. The results were satisfactory. It showed that the extracted envelope with the original signal has a high degree of matching, whether it is a low frequency portion or high frequency portion. Most of all information of heart sound has been maintained in the envelope.
The purpose of using brain-computer interface (BCI) is to build a bridge between brain and computer for the disable persons, in order to help them to communicate with the outside world. Electroencephalography (EEG) has low signal to noise ratio (SNR), and there exist some problems in the traditional methods for the feature extraction of EEG, such as low classification accuracy, lack of spatial information and huge amounts of features. To solve these problems, we proposed a new method based on time domain, frequency domain and space domain. In this study, independent component analysis (ICA) and wavelet transform were used to extract the temporal, spectral and spatial features from the original EEG signals, and then the extracted features were classified with the method combined support vector machine (SVM) with genetic algorithm (GA). The proposed method displayed a better classification performance, and made the mean accuracy of the Graz datasets in the BCI Competitions of 2003 reach 96%. The classification results showed that the proposed method with the three domains could effectively overcome the drawbacks of the traditional methods based solely on time-frequency domain when the EEG signals were used to describe the characteristics of the brain electrical signals.
We proposed a multi-resolution-wavelet-transform based method to extract brainstem auditory evoked potential (BAEP) from the background noise and then to identify its characteristics correctly. Firstly we discussed the mother wavelet and wavelet transform algorithm and proved that bi-orthogonal wavelet bior5.5 and stationary discrete wavelet transform (SWT) were more suitable for BAEP signals. The correlation analysis of D6 scale wavelet coefficients between single trails and the ensemble average of all trails showed that the trails with good correlation (> 0.4) had higher signal-to-noise ratio, so that we could get a clear BAEP from a few trails by an average and wavelet filter method. Finally, we used this method to select desirable trails, extracted BAEP from every 10 trails and calculated theⅠ-Ⅴinter-waves' latency. The results showed that this strategy of trail selection was efficient. This method can not only achieve better de-noising effect, but also greatly reduce the stimulation time needed as well.
All the collected original electroencephalograph (EEG) signals were the subjects to low-frequency and spike noise. According to this fact, we in this study performed denoising based on the combination of wavelet transform and independent component analysis (ICA). Then we used three characteristic parameters, complexity, approximate entropy and wavelet entropy values, to calculate the preprocessed EEG data. We then made a distinguishing judge on the EEG state by the state change rate of the characteristic parameters. Through the anesthesia and non-anesthesia EEG data processing results showed that each of the three state change rates could reach about 50.5%, 21.6%, 19.5%, respectively, in which the performance of wavelet entropy was the highest. All of them could be used as a foundation in the quantified research of depth of anesthesia based on EEG analysis.
Characteristics in pulse wave signals (PWSs) include the information of physiology and pathology of human cardiovascular system. Therefore, identification of characteristic points in PWSs plays a significant role in analyzing human cardiovascular system. Particularly, the characteristic points show personal dependent features and are easy to be affected. Acquiring a signal with high signal-to-noise ratio (SNR) and integrity is fundamentally important to precisely identify the characteristic points. Based on the mathematical morphology theory, we design a combined filter, which can effectively suppress the baseline drift and remove the high-frequency noise simultaneously, to preprocess the PWSs. Furthermore, the characteristic points of the preprocessed signal are extracted according to its position relations with the zero-crossing points of wavelet coefficients of the signal. In addition, the differential method is adopted to calibrate the position offset of characteristic points caused by the wavelet transform. We investigated four typical PWSs reconstructed by three Gaussian functions with tunable parameters. The numerical results suggested that the proposed method could identify the characteristic points of PWSs accurately.
Calculation of cardiac hemodynamic parameters is based on accurate detection of feature points in impedance cardiogram. According to these parameters, doctors can determine heart conditions, so it is very important to accurately detect the feature point of impedance differential signals. This article presents a process in which we used wavelet threshold method to de-noise signals, and then detected the feature points after six layers wavelet decomposition by using bior3.7. The experimental data were collected from healthy persons in our laboratory and twenty two clinical patients in Chongqing Daping Hospital by using KF_ICG instrument. The results indicated that this method could precisely detect feature points whether it was from healthy people or clinical patients. This helps to achieve the application of noninvasive detection cardiac hemodynamic parameters in clinical treatments by using impedance method.