• Department of Orthopedics, Changzheng Hospital, Affiliated to Second Military Medical University, Shanghai, 200003, P. R. China;
HOUChunlin, Email: chunlin_hou@163.com
Export PDF Favorites Scan Get Citation

Objective To evaluate the long-term effects on the lower limb function after S1 nerve root transection as dynamic source. Methods Between January 2007 and December 2011, 47 patients with atonic bladder dysfunction underwent S1 nerve root transposition to reconstrut the bladder function. There were 43 males and 4 females, with an average age of 40.7 years (range, 22-66 years). The locations were LS1 in 33 cases, LS2 in 5 cases, LS3 in 2 cases, TS12, LS1 in 3 cases, LS1, LS2 in 1 case, LS1, LS3 in 1 case, LS1, LS4 in 1 case, and LS2, LS3 in 1 case. The anastomosis of the SS2 or SS3 nerve root to S1 nerve root was performed from 4 to 24 months (mean, 8 months) after spinal cord injury. The strength of ankle plantar flexion was grade 4 in 5 cases and grade 5 in 42 cases before operation. Results The strength of ankle plantar flexion had no obvious decrease (grade 4 or 5) in 31 cases, reduced 0.5 grade in 16 cases at 2 days after operation. All the patients were followed up 3-8 years (mean, 5.1 years). At 2 weeks after operation, the nerve electrophysiological examination showed neurogenic damage at operated side in most patients, including reduced amplitude tibial nerve in 19 cases, for common peroneal nerve in 13 cases, and for tibial nerve and common peroneal nerve in 9 cases. Except the velocity of common peroneal nerve (t=-1.881, P=0.093), the other electric physiological indexes showed significant differences between at pre- and post-operation (P<0.05). The muscle strength basically recovered to preoperative level (grade 4 or 5) during follow-up, and there was no impairment of lower limb function. Conclusion S1 transection has no significant effects on lower limb function, so S1 nerve can be used as dynamic nerve for nerve function reconstruction.

Citation: LEIDeqiao, HOUChunlin, ZHAOJianguo, LINHaodong. LONG-TERM EFFECTS ON LOWER LIMB FUNCTION AFTER S1 NERVE ROOT TRANSECTION AS DYNAMIC SOURCE. Chinese Journal of Reparative and Reconstructive Surgery, 2015, 29(7): 849-852. doi: 10.7507/1002-1892.20150184 Copy

  • Previous Article

    APPLICATION OF HIGH VISCOSITY BONE CEMENT IN UNILATERAL PUNCTURE PERCUTANEOUS VERTEBROPLASTY FOR TREATMENT OF FRESH VERTEBRAL FRACTURE
  • Next Article

    STUDY ON RELATIONSHIP BETWEEN DIFFUSION TENSOR IMAGING AND VISUAL EVOKED POTENTIAL IN VISUAL PATHWAY OF NEUROMYELITIS OPTICA