1. |
李钧, 胡继超, 王西迅, 等. 人工掌指关节置换术的临床应用. 中华手外科杂志, 2008, 24(6): 384.
|
2. |
丁自海, 谢昌平, 裴国献, 等. 足趾关节移植重建手指关节的应用解剖. 中国临床解剖学杂志, 1995, 13(4): 241-244.
|
3. |
Nagao T, Pamies-Teixeira JJ, Suh NP. Behavior of medium carbon steel under combined fatigue and wear. Wear, 1977, 44(1): 101-108.
|
4. |
Agee J, Hollister AM, King F. The longitudinal axis of rotation of the metacarpophalangeal joint of the fingers. J Hand Surg (Am), 1986, 11: 767.
|
5. |
Brannon EW, Klein G. Experiences with a finger-joint prosthesis. J Bone Joint Surg (Am), 1959, 41-A(1): 87-102.
|
6. |
Beevers DJ, Seedhom BB. Metacarpophalangeal joint prostheses: a review of past and current designs. Proc Inst Mech Eng H, 1993, 207(4): 195-206.
|
7. |
Flatt AE. Restoration of rheumatoid finger-joint function: Interim report on trial of prosthetic replacement. J Bone Joint Surg, 1961, 43(5): 753-774.
|
8. |
Blair WF, Shurr DG, Buckwalter JA. Metacarpophalangeal joint implant arthroplasty with a Silastic spacer. J Bone Joint Surg (Am), 1984, 66(3): 365-370.
|
9. |
Case CP, Langkamer VG, James C, et al. Widespread dissemination of metal debris from implants. J Bone Joint Surg (Br), 1994, 76(5): 701-712.
|
10. |
Beevers DJ, Seedhom BB. Metacarpophalangeal joint prostheses. A review of the clinical results of past and current designs. J Hand Surg (Br), 1995, 20(2): 125-136.
|
11. |
贝朝涌, 李朝旭, 王锐英, 等. 人工关节置换术治疗掌指关节损伤 11 例临床观察. 广西医科大学学报, 2015, 32(6): 956-957.
|
12. |
Foliart DE. Swanson silicone finger joint implants: a review of the literature regarding long-term complications. J Hand Surg (Am), 1995, 20(3): 445-449.
|
13. |
Olsen L, Gebuhr P, Sonne-Holm S. Silastic arthroplasty in rheumatoid MCP-joints. 60 joints followed for 7 years. Acta Orthop Scand, 1994, 65(4): 430-431.
|
14. |
Synnott K, Mullett H, Faull H, et al. Outcome measures following metacarpophalangeal joint replacement. J Hand Surg (Br), 2000, 25(6): 601-603.
|
15. |
Swanson AB. Flexible implant arthroplasty for arthritic finger joint. Plast Reconstr Surg, 1973, 51(1): 105.
|
16. |
Swanson AB, Maupin BK, Gajjar NV, et al. Flexible implant arthroplasty in the proximal interphalangeal joint of the hand. J Hand Surg (Am), 1985, 10(6 Pt 1): 796-805.
|
17. |
Takigawa S, Meletiou S, Sauerbier M, et al. Long-term assessment of swanson implant arthroplasty in the proximal interphalangeal joint of the hand. J Hand Surg, 2004, 29(5): 785-795.
|
18. |
Chan K, Ayeni O, McKnight L, et al. Pyrocarbon versus silicone proximal interphalangeal joint arthroplasty: a systematic review. Plast Reconstr Surg, 2013, 131(1): 114-124.
|
19. |
Goldfarb CA, Stern PJ. Metacarpophalangeal joint arthroplasty in rheumatoid arthritis. A long-term assessment. J Bone Joint Surg (Am), 2003, 85(10): 1869-1878.
|
20. |
Minamikawa Y. Pathomechanics and treatment of the fingers in rheumatoid arthritis. Ryumachi, 2001, 41(6): 968-979.
|
21. |
Linscheid RL, Dobyns JH. Total joint arthroplasty. The hand. Mayo Clinic Proc, 1979, 54(8): 516-526.
|
22. |
Jennings CD, Livingstone DP. Surface replacement arthroplasty of the proximal interphalangeal joint using the PIP-SRA implant: results, complications, and revisions. J Hand Surg, 2008, 33(9): 1565.e1-1565.e11.
|
23. |
Daecke W, Kaszap B, Martini AK, et al. A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty. J Hand Surg (Am), 2012, 37(9): 1770-1779.
|
24. |
Stoecklein HH, Garg R, Wolfe SW. Surface replacement arthroplasty of the proximal interphalangeal joint using a volar approach: case series. J Hand Surg (Am), 2011, 36(6): 1015-1021.
|
25. |
Reissner L, Schindele S, Hensler S, et al. Ten year follow-up of pyrocarbon implants for proximal interphalangeal joint replacement. J Hand Surg, 2014, 39(6): 582-586.
|
26. |
Simpson-White RW, Chojnowski AJ. Pyrocarbon metacarpophalangeal joint replacement in primary osteoarthritis. J Hand Surg Eur Vol, 2014, 39(6): 575-581.
|
27. |
Nunley RM, Boyer MI, Goldfarb CA. Pyrolytic carbon arthroplasty for posttraumatic arthritis of the proximal interphalangeal joint. J Hand Surg (Am), 2006, 31(9): 1468-1474.
|
28. |
朱金国, 夏建龙. 人工关节材料的研究进展与骨科临床应用. 中国组织工程研究, 2008, 12(19): 3697-3700.
|
29. |
Schaffer AW, Pilger A, Engelhardt C, et al. Increased blood cobalt and chromium after total hip replacement. J Toxicol Clin Toxicol, 1999, 37(7): 839-844.
|
30. |
Jarrett BT, Cofske J, Rosenberg AE, et al. In vivo biological response to vitamin E and vitamin-E-doped polyethylene. J Bone Joint Surg (Am), 2010, 92(16): 2672-2681.
|
31. |
Cook SD, Klawitter JJ, Weinstein AM. The influence of implant elastic modulus on the stress distribution around LTI carbon and aluminum oxide dental implants. J Biomed Mater Res, 1981, 15(6): 879-887.
|
32. |
Vaidya C, Alvarez E, Vinciguerra J, et al. Reduction of total knee replacement wear with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene. Proc Inst Mech Eng H, 2011, 225(1): 1-7.
|
33. |
Daecke W, Veyel K, Wieloch P, et al. Osseointegration and mechanical stability of pyrocarbon and titanium hand implants in a load-bearing in vivo model for small joint arthroplasty. J Hand Surg (Am), 2006, 31(1): 90-97.
|