west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "印飞" 15 results
  • 动静脉转流术结合拔甲在幼儿 Ishikawa Ⅱ区断指再植中的应用

    目的 总结动静脉转流术结合拔甲用于幼儿 Ishikawa Ⅱ区断指再植中的疗效。 方法 2013 年 9 月—2018 年 3 月,采用动静脉转流术结合拔甲对 23 例远端无静脉吻合条件的幼儿 IshikawaⅡ区断指进行再植。男 16 例(19 指),女 7 例(7 指);年龄 1~3 岁,平均 2.3 岁。致伤原因:门挤压伤 8 例,重物压砸伤 7 例,机器轧伤 3 例,机械绞伤 5 例。伤指指别:示指 8 指,中指 10 指,环指 8 指。受伤至手术时间 3~9 h,平均 4.7 h。 结果 术后 5 例出现静脉回流障碍,2 例出现指尖挑拨口皮肤软组织部分坏死,均经对症处理后成活;其余断指再植后均顺利成活。23 例患儿均获随访,随访时间 3~14 个月,平均 9.4 个月。指尖外形佳、指腹饱满,指体无明显萎缩,指甲生长较平整,手指外形满意。再植手指远指间关节活动度无受限。 结论 动静脉转流术结合拔甲用于远端无静脉吻合条件的幼儿 Ishikawa Ⅱ区再植中,能提高再植成活率,临床疗效良好。

    Release date:2018-12-04 03:41 Export PDF Favorites Scan
  • 不携带一级源血管的游离股前外侧穿支皮瓣修复儿童手背创面

    目的总结不携带一级源血管的游离股前外侧穿支皮瓣修复儿童手背创面的效果。方法2015 年 1 月—2018 年 11 月,采用不携带一级源血管的游离股前外侧穿支皮瓣修复 6 例儿童手背创面。男 4 例,女 2 例;年龄 18 个月~14 岁,平均 4.6 岁。受伤至皮瓣修复时间为 4~13 d,平均 5.1 d。手背创面范围为 5 cm×4 cm~11 cm×8 cm,皮瓣切取范围为 5.0 cm×5.0 cm~20.0 cm×4.5 cm。供区均直接缝合。结果术后皮瓣均顺利成活;1 例创面愈合不良经换药后愈合,其余创面Ⅰ期愈合。供区切口均Ⅰ期愈合。患儿均获随访,随访时间 5~43 个月,平均 22.3 个月。末次随访时,皮瓣外形、质地均满意,有排汗功能,恢复部分浅感觉;根据中华医学会手外科学会上肢部分功能评定试用标准:优 2 例,良 2 例,中 2 例。结论不携带一级源血管的游离股前外侧穿支皮瓣修复儿童手背创面具有血供可靠、供受区损伤小的优点,能获得较好疗效。

    Release date:2019-12-23 09:44 Export PDF Favorites Scan
  • A COMPARATIVE STUDY ON TREATMENT OF THORACOLUMBAR FRACTURE WITH INJURED VERTEBRA PEDICLE INSTRUMENTATION AND CROSS SEGMENT PEDICLE INSTRUMENTATION

    ObjectiveTo compare the effective of short-segment pedicle instrumentation with bone grafting and pedicle screw implanting in injured vertebra and cross segment pedicle instrumentation with bone grafting in injured vertebra for treating thoracolumbar fractures. MethodsA prospective randomized controlled study was performed in 40 patients with thoracolumbar fracture who were in accordance with the inclusive criteria between June 2010 and June 2012. Of 40 patients, 20 received treatment with short-segment pedicle screw instrumentation with bone grafting and pedicle screw implanting in injured vertebra in group A, and 20 received treatment with cross segment pedicle instrumentation with bone grafting in injured vertebra in group B. There was no significant difference in gender, age, affected segment, disease duration, Frankel grade, Cobb angle, compression rate of anterior verterbral height, visual analogue scale (VAS) score, and Japanese Orthopaedic Association (JOA) score between 2 groups before operation (P>0.05). The operation time, blood loss, Cobb angle, compression rate of anterior vertebral height, loss of disc space height, Frankel grade, VAS and JOA scores were compared between 2 groups. ResultsThere was no significant difference in the operation time and blood loss between 2 groups (P>0.05). Primary healing of incision was obtained in all patients, and no early complication of infection or lower limb vein thrombus occurred. Forty patients were followed up 12-16 months (mean, 14.8 months). No breaking or displacement of internal fixation was observed. The improvement of Frankel grading score was 0.52±0.72 in group A and 0.47±0.63 in group B, showing no significant difference (t=0.188, P=0.853) at 12 months after operation. The Cobb angle, compression rate of anterior verterbral height, and VAS score at 1 week and 12 months, and JOA score at 12 months were significantly improved when compared with preoperative ones in 2 groups (P<0.05). No significant difference was found in Cobb angle, disc space height, VAS score, and JOA score between 2 groups at each time point (P>0.05), but the compression rate of anterior verterbral height in group A was significantly lower than that in group B (P<0.05). The loss of disc space height next to the internal fixation or the injured vertebra was observed in 2 groups at 12 months, but showing no significant difference (P>0.05). ConclusionCompared with cross segment pedicle instrumentation, short-segment pedicle screw instrumentation with bone grafting and pedicle screw implanting in injured vertebra can recover and maintain the affected vertebra height in treating thoracolumbar fractures, but it could not effectively prevent degeneration of adjacent segments and the loss of kyphosis correction degree.

    Release date: Export PDF Favorites Scan
  • 肘关节后方入路结合钢板螺钉内固定治疗向后孟氏骨折脱位

    目的总结肘关节后方单切口入路结合钢板螺钉内固定治疗向后孟氏骨折脱位的疗效。 方法2012年1月-2014年1月,收治9例向后孟氏骨折脱位患者,均经肘关节后方单切口入路行钢板螺钉内固定。男6例,女3例;年龄25~49岁,平均33.7岁。致伤原因:高处坠落伤5例,摔伤4例。骨折分型:Jupiter A型3例,B型4例,C型2例。均合并不同程度桡骨小头骨折。伤后至手术时间为5~9 d,平均6.5 d。 结果术后患者切口均Ⅰ期愈合。9例患者均获随访,随访时间13~32个月,平均16.3个月。X线片复查示骨折均愈合,愈合时间2~4个月,平均3.2个月;随访期间无创伤性骨关节炎及异位骨化等发生。末次随访时,Mayo肘关节功能评分87~95分,平均91.7分;其中优6例,良3例,优良率100%。 结论采用肘关节单切口入路结合钢板螺钉内固定治疗向后孟氏骨折脱位具有手术视野显露充分、损伤小等优点,可获得较好疗效。

    Release date: Export PDF Favorites Scan
  • A COMPARATIVE STUDY ON TREATMENT OF MID-THORACIC OSTEOPOROTIC VERTEBRAL COMPRESSION FRACTURE USING PERCUTANEOUS KYPHOPLASTY WITH UNILATERAL AND BILATERAL APPROACHES

    ObjectiveTo compare the effectiveness of percutaneous kyphoplasty (PKP) between by unilateral approach and by bilateral approaches for treating mid-thoracic osteoporotic vertebral compression fracture (OVCF). MethodA prospective randomized controlled study was performed on 22 patients with mid-thoracic OVCF between September 2012 and June 2014. PKP was performed by unilateral approach in 11 cases (group A) and by bilateral approaches in 11 cases (group B). There was no significant difference in gender, age, causes of injury, disease duration, affected segment, preoperative bone mineral density, Cobb angle, compression rate of the anterior verterbral height, and Visual analogue scale (VAS) score between 2 groups (P>0.05) . The operation time, perspective times, hospitalization expenses, the leakage of cement, the sagittal Cobb angle, compression rate of the anterior vertebral height, and VAS scores were compared between 2 groups. ResultsThe operation time, perspective times, and hospitalization expenses of group A were significantly less than those of group B (P<0.05) . Twenty-two patients were followed up 13-34 months (mean, 15.3 months). Primary healing of incision was obtained in all patients, and no early complication of cement leakage, hypostatic pneumonia, or deep vein thrombosis occurred. At last follow-up, no new fracture occurred at the adjacent segments. The Cobb angle, compression rate of anterior verterbral height, and VAS score at 1 week and last follow-up were significantly improved when compared with preoperative ones in 2 groups (P<0.05) , but no significant difference was found between at 1 week and at last follow-up (P>0.05) . There was no significant difference in Cobb angle, compression rate of the anterior vertebral height, and VAS score between 2 groups at each time point (P>0.05) . ConclusionsPKP by both unilateral approach and bilateral approaches has the same effectiveness, but unilateral approach has shorter operation time, less perspective times, and less hospitalization expenses than bilateral approaches.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF PROXIMAL FEMORAL NAIL ANTI-ROTATION IN SUPINE “SCISSORS” POSITION AND IN LITHOTOMY POSITION TO TREAT FEMORAL INTERTROCHANTERIC FRACTURES OF OLD PATIENTS

    ObjectiveTo compare the effectiveness of proximal femoral nail anti-rotation (PFNA) between in the supine "scissors" position and in the lithotomy position for treating femoral intertrochanteric fractures of old patients. MethodsA retrospective study was performed on 58 patients with femoral intertrochanteric fractures treated with PFNA between January 2013 and January 2015. Fracture was treated with PFNA in the lithotomy position in 28 cases (group A) and in the supine "scissors" position in 30 cases (group B). There was no significant difference in gender, age, side, cause of injury, fracture type, and interval from injury to operation between 2 groups (P>0.05). The incision length, operation time, perspective times, intraoperative blood loss, complications, and fracture healing time were recorded; Harris hip score was used to access the effectiveness. ResultsThe wound healed by first intention without infection, pressure sores, deep vein thrombosis of lower extremity, and other complications. There was no significant difference in incision length between 2 groups (t=1.313, P=0.212). Group B was significantly better than group A in operation time, perspective times, and intraoperative blood loss (P<0.05). All patients were followed up 10-31 months (mean, 15.3 months). Stretch injury at normal side and perineal discomfort occurred in 1 case and 5 cases of group A respectively, and no nonunion and other complications was observed in the other patients. There was no significant difference in fracture healing time and Harris hip score at last follow-up between 2 groups (P>0.05). ConclusionPFNA in the supine "scissors" position has exact effectiveness and advantages of shorter operation time, less intraoperative blood loss, less perspective times, and fewer complications.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF CORACOCLAVICULAR LIGAMENT RECONSTRUCTION BETWEEN BY AUTOLOGOUS AND ALLOGENEIC TENDON GRAFTS COMBINED WITH HOOK PLATE FIXATION FOR TREATING ACROMIOCLAVICULAR JOINT DISLOCATION

    ObjectiveTo compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. MethodsThirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A (n=17), and with allogeneic tendon graft combined with hook plate fixation in group B (n=16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation (P>0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. ResultsThe operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B (P<0.05). There was no significant difference in hospitalization time (t=1.046, P=0.316). The incisions healed by first intention, and hook plate was removed after 3 months. The mean follow-up time was 21.3 months (range, 19-34 months) in group A and was 23.7 months (range, 18-37 months) in group B. X-ray examination showed no osteolysis. There was no significant difference in gap of acromiocavicular between 2 groups at preoperation, 1 week after operation, and last follow-up (P>0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups (P>0.05). ConclusionCoracoclavicular ligament reconstruction by autologous plantaris tendon or allogeneic tendon graft combined with hook plate fixation for the treatment of acromioclavicular joint dislocation can achieve good effectiveness. The appropriate treatment should be chosen according to the patient's economic situation.

    Release date: Export PDF Favorites Scan
  • Treatment of thoracolumbar burst fractures with short-segment pedicle instrumentation and recombinant human bone morphogenetic protein 2 and allogeneic bone grafting in injured vertebra

    Objective To investigate the effect of preventing the loss of correction and vertebral defects after thoracolumbar burst fractures treated with recombinant human bone morphogenetic protein 2 (rhBMP-2) and allogeneic bone grafting in injured vertebra uniting short-segment pedicle instrumentation. Methods A prospective randomized controlled study was performed in 48 patients with thoracolumbar fracture who were assigned into 2 groups between June 2013 and June 2015. Control group (n=24) received treatment with short-segment pedicle screw instrumentation with allogeneic bone implanting in injured vertebra; intervention group (n=24) received treatment with short-segment pedicle screw instrumentation combining with rhBMP-2 and allogeneic bone grafting in injured vertebra. There was no significant difference in gender, age, injury cause, affected segment, vertebral compression degree, the thoracolumbar injury severity score (TLICS), Frankel grading for neurological symptoms, Cobb angle, compression rate of anterior verterbral height between 2 groups before operation (P>0.05). The Cobb angle, compression rate of anterior vertebral height, intervertebral height changes, and defects in injured vertebra at last follow-up were compared between 2 groups. Results All the patients were followed up 21-45 months (mean, 31.3 months). Bone healing was achieved in 2 groups, and there was no significant difference in healing time of fracture between intervention group [(7.6±0.8) months] and control group [(7.5±0.8) months] (t=0.336, P=0.740). The Frankel grading of all patients were reached grade E at last follow-up. The Cobb angle and compression rate of anterior verterbral height at 1 week after operation and last follow-up were significantly improved when compared with preoperative ones in 2 groups (P<0.05). There was no significant difference in Cobb angle and compression rate of anterior verterbral height between 2 groups at 1 week after operation (P>0.05), but the above indexes in intervention group were better than those in control group at last follow-up (P<0.05). At last follow-up, there was no significant difference of intervertebral height changes of internal fixation adjacent upper position, injured vertebra adjacent upper position, injured vertebra adjacent lower position, and internal fixation adjacent lower position between 2 groups (P>0.05). Defects in injured vertebra happened in 18 cases (75.0%) in control group and 5 cases (20.8%) in intervention group, showing significant difference (χ2=14.108, P=0.000); and in patients with defects in injured vertebra, bone defect degree was 7.50%±3.61% in control group, and was 2.70%±0.66% in intervention group, showing significant difference (t=6.026, P=0.000). Conclusion Treating thoracolumbar fractures with short-segment pedicle screw instrumentation with rhBMP-2 and allogeneic bone grafting in injured vertebra can prevent the loss of correction and vertebral defects.

    Release date:2017-09-07 10:34 Export PDF Favorites Scan
  • Diagnosis and treatment of thumb polydactyly with symphalangism in children

    ObjectiveTo investigate the diagnosis and treatment of thumb polydactyly with symphalangism in children.MethodsSeven cases of thumb polydactyly with symphalangism were treated between January 2013 and May 2017. There were 5 males and 2 females, aged from 10 months to 11 years, with an average age of 3.1 years. The thumb-polydactyly was diagnosed with MRI and it was seen that the base of radial multi-finger and the proximal phalangeal joint were connected by cartilage. All patients were treated with resection, lateral collateral ligament reconstruction, bone osteotomy and internal fixation.ResultsThe operation was successfully completed, and there was no early complications such as infection and flap necrosis. All patients were followed up 6-23 months (mean, 14.1 months). At last follow-up, there was no deformity finger, scar contracture, and other complications. The extension of the interphalangeal joint was no limited, and the flexion range of the interphalangeal joint was 20-75° (mean, 56.7°). The appearance and function of the thumb was rated as excellent in 3 cases and good in 4 cases by Japanese Society for Surgery of the Hand (JSSH) scoring, with the excellent and good rate of 100%.ConclusionThe thumb polydactyly with symphalangism in children can be combined with clinical manifestations, X-ray film, and MRI examination to diagnose, and can obtain satisfactory results through the reconstruction of lateral collateral ligament, bone osteotomy, and internal fixation.

    Release date:2018-10-09 10:34 Export PDF Favorites Scan
  • Application of anterograde fascial flap of digital artery in Wassel Ⅳ-D thumb duplication reconstruction

    ObjectiveTo explore the effectiveness of anterograde fascial flap of digital artery in reconstruction of Wassel Ⅳ-D thumb duplication.MethodsTwelve cases of Wassel Ⅳ-D thumb duplication were treated with anterograde fascial flap of digital artery between June 2014 and March 2017. There were 7 boys and 5 girls with an age of 9-32 months (mean, 13.3 months). Eight cases were on the left side and 4 cases on the right side. The main bunion bed width was 70%-85% of the healthy side (mean, 75.3%). The degree of fullness was 50%-75% of the healthy side (mean, 62.4%). The anterograde fascial flap with one proper digital artery was used to fill the nail fold on the radial side of the finger and increase the circumference of the finger. At last follow-up, the ratio of circumference of deformed finger to contralateral finger was measured at the base of nail. The appearance and function of all reconstructed thumbs were evaluated with Japanese Society for Surgery of the Hand (JSSH) scoring.ResultsAll the operations were successfully completed without early complications such as infection and skin necrosis. All children were followed up 7-27 months (mean, 14.3 months). At last follow-up, there was no recurrence of deformity in the digital body and no obvious change of scar contracture in the surgical wound. Pulp and nail fold symmetry improved in all cases. The ratio of circumference of deformed finger to contralateral finger was 93%-96% (mean, 94.7%). The JSSH score was 15-20 (mean, 17.9); the results were excellent in 8 cases, good in 2 cases, and fair in 2 cases.ConclusionThe anterograde fascial flap of digital artery is a safe and effective approach to restore symmetry for esthetic improvement in treatment of Wassel Ⅳ-D thumb duplication.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content