Monitoring airway impedance has significant clinical value in accurately assessing and diagnosing pulmonary function diseases at an early stage. To address the issue of large oscillator size and high power consumption in current pulmonary function devices, this study adopts a new strategy of expiration-driven oscillation. A lightweight and low-power airway impedance monitoring system with integrated sensing, control circuitry, and dynamic feedback system, providing visual feedback on the system’s status, was developed. The respiratory impedance measurement experiments and statistical comparisons indicated that the system could achieve stable measurement of airway impedance at 5 Hz. The frequency spectrum curves of respiratory impedance (R and X) showed consistent trends with those obtained from the clinical pulmonary function instrument, specifically the impulse oscillometry system (IOS). The differences between them were all less than 1.1 cm H2O·s/L. Additionally, there was a significant statistical difference in the respiratory impedance R5 between the exercise and rest groups, which suggests that the system can measure the variability of airway resistance parameters during exercise. Therefore, the impedance monitoring system developed in this study supports subjects in performing handheld, continuous measurements of dynamic changes in airway impedance over an extended period of time. This research provides a foundation for further developing low-power, portable, and even wearable devices for dynamic monitoring of pulmonary function.
This study aimed to evaluate the effect of sanguinarine on biomechanical properties of rat airway smooth muscle cells (rASMCs) including stiffness, traction force and cytoskeletal stress fiber organization. To do so, rASMCs cultured in vitro were treated with sanguinarine solution at different concentrations (0.005~5 μmol/L) for 12 h, 24 h, 36 h, and 48 h, respectively. Subsequently, the cells were tested for their viability, stiffness, traction force, migration and microfilament distribution by using methylthiazolyldiphenyl-tetrazolium bromide assay, optical magnetic twisting cytometry, Fourier transform traction microscopy, scratch wound healing method, and immunofluorescence microscopy, respectively. The results showed that at concentration below 0.5 μmol/L sanguinarine had no effect on cell viability, but caused dose and time dependent effect on cell biomechanics. Specifically, rASMCs treated with sanguinarine at 0.05 μmol/L and 0.5 μmol/L for 12 and 24 h exhibited significant reduction in stiffness, traction force and migration speed, together with disorganization of the cytoskeletal stress fibers. Considering the essential role of airway smooth muscle cells (ASMCs) biomechanics in the airway hyperresponsiveness (AHR) of asthma, these findings suggest that sanguinarine may ameliorate AHR via alteration of ASMCs biomechanical properties, thus providing a novel approach for asthma drug development.
The properties of mucus in a person with asthma can alter with disease process so that it may lead to the airway embolism. Fe2O3 nanoparticles can be used for drug delivery. Up till now, however, little is known about how the Fe2O3 nanoparticles influence the properties of airway mucus. In this study, Fe2O3 nanoparticles were dispersed with ultrasound, and the morphological properties were measured with scanning electron microscope, atomic force microscope and nanometer laser particle size and zeta potential analyzer. Then the dispersed Fe2O3 nanoparticles were added to the simulated asthma airway mucus with different final concentration (0.03, 0.3, and 0.4 mg/mL). The measurements of flow curve, yield stress, large amplitude oscillatory shear (LAOS) and shock scanning were carried out with a rotational rheometer. Experimental results showed that the Fe2O3 nanoparticles reduced the zero shear viscosity of simulated asthma airway mucus. With increase of shear rate, the wind speed of mucus was reduced. The yield stress of simulated asthma airway mucus was 19.0 Pa, but the yield stresses of experimental group (0.03, 0.3 and 0.4 mg/mL) were 17.0, 0.99, and 0.7 Pa, respectively. The results showed that the viscoelastic modulus of asthma airway mucus treated with Fe2O3 nanoparticles were changed obviously as measured with large amplitude scanning and frequency scanning. By adopting the method of optical phase microscopy, we found that different structures of simulated airway mucus were absorbed. The results showed Fe2O3 nanoparticles distroyed mucus structure. The experimental results proved that Fe2O3 nanoparticles could change the rheological characteristics of simulated asthma airway mucus. This experimental result would lay a foundation for the further development of airway mucus sticky agent based on the function of Fe2O3 nanoparticles.