west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "JIA Dan" 3 results
  • Impact of acoustic environmental pollution in outpatient clinics on medical staff and visitors and its countermeasures

    Acoustic environment is an important part of the overall environment of a hospital. Acoustic environmental pollution will have varying degrees of impact on human physiology and psychology. Acoustic environmental pollution in outpatient clinics has become a major concern for visitors and medical staff. Exploring the causes of outpatient acoustic environment pollution and adopting active countermeasures are effective methods to control outpatient acoustic environment pollution. This article will review the current situation of acoustic environmental pollution in outpatient clinics and the impact of acoustic environmental pollution on medical staff and visitors, and analyze the common causes of outpatient acoustic environmental pollution based on actual conditions, and propose corresponding solutions for the corresponding causes. It aims to provide a reference for clinically effective control of acoustic environmental pollution in outpatient clinics.

    Release date: Export PDF Favorites Scan
  • Analysis and consideration on the construction of multi-disciplinary team service system for rare diseases

    Rare diseases are a kind of diseases with very low incidence and prevalence. They are difficult to diagnose, treat and use drugs. Multi-disciplinary team (MDT) has become the main mode of modern medical diagnosis and treatment. Many hospitals at home and abroad have begun to apply MDT in the diagnosis and treatment of rare diseases. This paper introduces the MDT mode of rare diseases at home and abroad, focusing on the mode, work flow and content of the MDT service system for rare diseases in West China Hospital of Sichuan University, and discusses the problems and optimization suggestions of the current construction of the MDT service system for rare diseases. The purpose is to provide some reference for the establishment of MDT model of rare diseases in China.

    Release date: Export PDF Favorites Scan
  • Rapid and accurate measurement of body temperature in dense population during coronavirus disease 2019 pandemic

    ObjectiveTo study the method of rapid and accurate measurement of body temperature in dense population during the coronavirus disease 2019 pandemic.MethodsFrom January 27th to February 8th, 2020, subjects were respectively measured with two kinds of non-contact infrared thermometers (blue thermometer and red one) to measure the temperature of forehead, neck, and inner side of forearm under the conditions of 4–6℃ (n=152), 7–10℃ (n=103), and 11–25℃ (n=209), while the temperature of axillary was measured with mercury thermometer under the same conditions. Taking the mercury thermometer temperature as the gold standard, the measurement results with non-contact infrared thermometers were compared.ResultsAt 7–10℃, there was no statistical difference among the forehead temperatures measured by the two non-contact infrared thermometers and the axillary temperature (P>0.05); there was no difference among the temperature measured by blue thermometer on forehead, neck, and inner side of forearm (P>0.05); no difference was found between the temperature measured by the red thermometer on forehead and inner side of forearm (P>0.05), while there was statistical difference between the temperatures measured by the red thermometer on forehead and neck (P<0.05). Under the environment of 11−25℃, there was no statistical difference among the forehead temperatures measured by the two infrared thermometers and the axillary temperature (P>0.05); the difference between the temperatures of forehead and inner side of forearm measured by the blue thermometer was statistically significant (P<0.05), while no difference appeared between the forehead and neck temperatures measured by the blue thermometer (P>0.05); there was no statistical difference among the temperatures of three body regions mentioned above measured by the red thermometer (P>0.05). According to the manual, the allowable fluctuation range of the blue thermometer was 0.3℃, and that of the red one was 0.2℃. The mean differences in measured values between different measured sites of the two products were within the allowable fluctuation range. Therefore, the differences had no clinical significance in the environment of 7–25℃. Under the environment of 4–6℃, the detection rate of blue thermometer was 2.2% and that of the red one was 19.1%.ConclusionsThere is no clinical difference between the temperature measured by mercury thermometer and the temperature measured by temperature guns at 7–10 or 11–25℃, so temperature guns can be widely used. In order to maintain the maximum distance between the measuring and the measured persons and reduce the infection risk, it is recommended to choose the inner forearm for temperature measurement. Under the environment of ambient temperature 4–6℃, the detection rate of non-contact electronic temperature gun is low, requiring taking thermal measures for the instrument.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content