west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "elastography" 20 results
  • Evaluation of Coagulation in Orthotopic Liver Transplantation with Thrombelastography

    ObjectiveTo evaluate the changes in thrombelastography(TEG) during orthotopic liver transplantation (OLT) in Chinese. MethodsTwentyfive patients with cirrhosis of liver undergoing OLT were studied. They were composed of two groups: cirrhosis group (n=15) and liver neoplasm group (n=10). Anesthesia was induced with propofol 1.5-2 mg/kg,fentanyl 3-5 μg/kg and vecuronium 0.1 mg/kg and maintained with isoflurane or enflurane inhalation.The operation was divided into three phases: ① before operation and preanhepatic phase (120 min after operation was started), ② 30 min after liver was removed,③ 5 min before reperfusion and 5 min,15 min,30 min,60 min and 120 min after reperfusion.In 8 patients among the 25 patients heparinasecelite TEG was measured 5 min after reperfusion in addition to celite TEG.If there was significant differences in traces between the two TEG measurements,an intravenous bolus of 50-75 mg protamine was given and the heparinasecelite TEG was repeated.The measured variables included the r (reaction) time,representing the rate of initial fibrin formation K (coagulation) time, alpha angles (α) reflecting fibrinplatelet interaction, MA (maximal amplitude) indicating qualitative platelet function and percent fibrinolysis at 60 min. ResultsIn cirrhosis group changes in TEG occurred after liver was removed and in earlier period after reperfusion, while in liver neoplasm group changes in TEG were found in earlier period after reperfusion as compared with preoperative value.At 5 min after reperfusion there were significant differences in TEG (r,K,α and MA) values between celite and heparincelite TEG (P<0.01). ConclusionDuring OLT coagulation disorder occurs mainly at anhepatic and early reperfusion phase.

    Release date:2016-08-28 04:49 Export PDF Favorites Scan
  • APPLICATION OF ACUTE EXTREME HYPERVOLEMIC HEMODILUTION IN SPINE SURGERY

    Objective To evaluate the security and validity of the acute extreme hypervolemic hemodilution (AEHH) in spine surgery. Methods Thirteen patients(8 males, 5 females; age, 16-65 years; weight, 50-75 kg) who had undergone major spine operations were enrolled in this study. Eleven of them had undergone anterior decompression, who were given the grafting and the internal fixation for their thoracolumber spinal burst fractures; the other 2 patients were given the correction operation for their scoliosis. The baselines of the haematocrit (Hct)were 0.363-0.481 before operation. The patients had no cardiac, pulmonary, hepatic or renal dysfunction or coagulation abnormality. The hemodynamic status and the haematocrit were observed during operation. The parameters of thromboelastography (TEG),arterial blood gas, and electrolytes were measured and observed at the following time points: before AEHH, after AEHH, 60 minutes after AEHH, 120 minutes after AEHH, and the end of the operation. The total fluid volume was recorded. Results The autologous blood volume was1 050-1 575 ml (average,1 419±198 ml), plasma substitute 2 100-3 150 ml (average,2 838±397 ml), blood loss1 000-3 130 ml (average, 1 747±743 ml), urine 450-1 270 ml (average, 871±374 ml), and the net blood transfusion 1 206-2 661 ml(1 863±598 ml). The homogenous blood of 400 ml was transfused in 1 patient for making upthe blood loss of 3 130 ml. There were no statistically significant differencesin the hemodynamic measurements, arterial blood gas, and electrolyte variables when compared with the baseline values before the hemodilution (Pgt;0.05). The reaction time of TEG was longer 60 minutes after AEHH than before AEHH (Plt;0.05); the other parameters of TEG had no differences when compared with the baseline values (Pgt;0.05). Conclusion The AEHH is safe and efficient in reduction of the perioperative homogenous blood transfusion in spine surgery.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • The Initial Study of Real-time Shear Wave Elastography in Parotid and Submaxillary Gland of Healthy Adults

    ObjectiveTo study the Young's modulus obtained by the real-time shear wave elastography (SWE) in healthy adults' parotid gland and submaxillary gland and to explore the probable factors affecting the Young's modulus, such as bilateral parotid and submaxillary gland, sex, age, height and weight. MethodsThere were 35 healthy volunteers who underwent SWE in parotid gland and submaxillary gland between December 3 and 18, 2013. The difference of Young's modulus in bilateral parotid and submaxillary gland, and the modulus values of different sex, age, height and weight groups were also compared. ResultsThe Young's modulus of parotid gland was (8.14±1.78) kPa, and the Young's modulus of submaxillary gland was (11.52±2.34) kPa. The differences of Young's modulus between the two sides of parotid gland and submaxillary gland were not statistically significant (P>0.05); the differences of Young's modulus of parotid and submaxillary gland between different sex, age, height and weight groups had no statistical significance, either (P>0.05). ConclusionThe real-time shear wave elastography can be applied to evaluate the elasticity of parotid and submaxillary gland and to lay the foundation for further diagnosis of salivary lesions.

    Release date: Export PDF Favorites Scan
  • Real-time Tissue Elastography for Evaluation of Liver Fibrosis in Patients with Type B Chronic Hepatitis

    ObjectiveTo explore the significance of quantitative parameters of tissue diffusion included in the real-time ultrasound elastography (RTE), in diagnosing the degree of liver fibrosis. MethodFrom July 2012 to November 2014, liver biopsy being the gold standard for evaluating hepatic fibrosis stage, we performed RTE on 112 hepatitis patients and analyzed the elastogram we got. At the same time, we carried out quantitative analysis of tissue diffusion in these patients, and obtained the values of liver fibrosis index (LFI) of right liver parenchyma. Subsequently, we compared the biopsy pathological results with the values of LFI, and single-factor analysis of variance (ANOVA) was adopted to compare the LFI among patients with variant degrees of liver fibrosis. If there were any discrepancies, least significant difference method would be adopted in order to compare one with the other from different groups. Finally, critical value of LFI of different-stage liver fibrosis was obtained with the help of receiver operator characteristic (ROC)curve. ResultsChronological liver fibrosis was classified into stage 0, stage 1, stage 2, stage 3, and stage 4, and their LFI values were 2.36±0.46, 2.38±0.45, 2.84±0.54, 3.16±0.59, and 3.69±0.55, respectively. ANOVA showed that the LFI values of different-stage fibrosis had significant differences (F=29.959, P<0.001). However, there was no difference between stage 0 and stage 1 (P=0.920), or between stage 2 and stage 3 (P=0.076). The area under the ROC curve for stage 0-1 and stage 2-3, stage 2-3 and S4 was respectively 0.784 and 0.799, and their critical value was 2.83 and 3.69 respectively. ConclusionsThe real-time ultrasound elastography is a feasible and non-invasive method in diagnosing the degree of hepatitis fibrosis and LFI has advantage in distinguishing different stage of liver fibrosis.

    Release date: Export PDF Favorites Scan
  • Arterial Plaques Identification Based on Intravascular Ultrasound Elasticity Imaging

    Intravascular ultrasound (IVUS) is widely used in coronary artery examination. Ultrasonic elastography combined with IVUS is very conspicuous in identifying plaque component and in detecting plaque vulnerability degree. In this study, a simulation model of the blood vessel based on finite element analysis (FEA) was established. The vessel walls generally have radial changes caused by different intravascular pressure. The signals at lower pressures were used as the pre-deformation data and the signals at higher pressure were used as the post-deformation data. Displacement distribution was constructed using the time-domain cross-correlation method, and then strain images. By comparison of elastograms under different pressures, we obtained the optimal pressure step. Furthermore, on the basis of the obtained optimize pressure step, the simulation results showed that this method could effectively distinguish characteristics between different component plaques, and could guide the later experiments and clinical applications.

    Release date: Export PDF Favorites Scan
  • Transient Elastography: Progress in Predicting The Prognosis of Hepatic Surgery

    ObjectiveTo summarize the progress of transient elastography in predicting the prognosis of hepatic surgery. MethodsThe related literatures were reviewed. ResultsLiver stiffness can be measured by using transient elastography.In patients with hepatocarcinoma, the liver stiffness measurements are higher, the more likely they are to have surgical complications and hepatocarcinoma recurrence.Liver transplant recipients with higher liver stiffness measurements tend to have higher acute rejection and hepatitis C recurrence rates. ConclusionTransient elastography can evaluate hepatic functional reserve to help improve the outcome of hepatic surgery.

    Release date: Export PDF Favorites Scan
  • Influence of Hydroxyethyl Starch on Blood Coagulation of Patients after off-pump Coronary Artery Bypass Grafting by Thromboelastography

    ObjectiveTo investigate the influence of 6% hydroxyethyl starch (HES, 130/0.4)on blood coagulation of patients after off-pump coronary artery bypass grafting (opCAB)by thromboelastography (TEG). MethodsOne hundred patients undergoing elective opCAB in Department of Cardiovascular Surgery, General Hospital of Shenyang Military Area Command between May and July 2013 were enrolled in this study. All the patients were randomly divided into 2 groups using random number table method with 50 patients in each group. In the experimental group (G1 group), there were 27 males and 23 females with their age of 64.9±4.4 years, who received intravenous 6% HES (130/0.4)20 ml/kg in 4 hours postoperatively. In the control group (G2 group), there were 31 males and 19 females with their age of 63.1±5.8 years, who received intravenous lactated ringers 20 ml/kg in 4 hours postoperatively. After postoperative ICU admission, full blood count, coagulation tests and TEG were examined. Chest and mediastinal drainage was recorded at 6 hours and 24 hours postoperatively. ResultsThere was no statistical difference in chest and mediastinal drainage 24 hours postoperatively between the 2 groups (591.7±171.7 ml vs. 542.4±174.0 ml, P > 0.05). None of the patients received reexploration for bleeding. There was no statistical difference in hemoglobin, hematocrit, platelet count or traditional coagulation index between the 2 groups (P > 0.05). TEG showed no significant change in coagulation time after intravenous fluid infusion in either group. Reaction time was slightly extended in both groups, but there was no statistical difference in reaction time between the 2 groups (P > 0.05). Maximum amplitude (MA)of G1 group was significantly decreased after intravenous fluid infusion (55.9±10.0 mm vs. 62.8±7.9 mm, P < 0.05), but still within the normal range. There was no significant change in MA after intravenous fluid infusion in G2 group. ConclusionIntravenous infusion of 6% HES (130/0.4)20 ml/kg can reduce platelet function and clot strength, but does not significantly increase postoperative chest or mediastinal drainage, or the incidence of postoperative reexploration for bleeding. It's safe to administer 6% HES (130/0.4)for patients after OPCAB.

    Release date: Export PDF Favorites Scan
  • Value of Ultrasonographic Elastography in Differential Diagnosis of Benign/Malignant Thyroid Nodules in China: A Meta-Analysis

    ObjectiveTo systematically review the clinical value of ultrasonographic elastography (UE) for the differential diagnosis of benign/malignant thyroid nodules. MethodsWe comprehensively searched the databases including The Cochrane Library (Issue2, 2013), PubMed, EMbase, CNKI, WanFang Data, Medalink, VIP and CBM from inception to the December of 2013, for including clinical research reports of determining thyroid nodules using ultrasonographic elastography. Literature screening according to the inclusion and exclusion criteria, data extraction and methodological quality assessment were completed by two reviewers independently. Then Meta-DiSc software (version 1.4) was used for pooling analysis. ResultsA total of 35 studies including 4 127 patients were included. The results of metaanalysis showed that, specificity, sensitivity, positive likelihood radio, negative likelihood radio and diagnostic odds ratio (DOR) were 0.89 (0.88 to 0.90), 0.88 (0.86 to 0.90), 6.37 (5.44 to7.47), 0.13 (0.11 to 0.16) and 58.72 (43.12 to 79.98), respectively; and the area under SROC curve (AUC) was 0.936 9. ConclusionCurrent evidence shows that ultrasonographic elastography has fairly high sensitivity (88%) and specificity (89%) in differential diagnosis of benign/malignant thyroid nodules. The positive rate in the malignant thyroid group is 58.72 times higher that in benign thyroid cancer with better efficacy in differential diagnosis, so ultrasonographic elastography is of effective and feasible diagnostic value for thyroid benign/malignant nodules.

    Release date: Export PDF Favorites Scan
  • The diagnostic value of real-time tissue elastography in differentiating benign and malignant breast tumors

    ObjectiveTo explore the value of ultrasound real-time tissue elastography in the differential diagnosis between benign and malignant breast lesions.Methods A total of 131 cases of patients with breast lesions who underwent ultrasound examination in the People’s Hospital of Guangan City between December 2010 and December 2015 were enrolled as the research object. The patients took conventional color Doppler ultrasound diagnosis firstly, and then took ultrasound real-time tissue elastography diagnosis. The lesions were scored with improved 5-scoring system respectively. By the strain ratio measure method equipped with the ultrasonic machine, strain ratio of the lesion was calculated, with 3.08 as the cut-off pont. The results were campared with the pathologic diagnosis.ResultsThere were 182 breast lumps in the 131 patients. The conventional ultrasound examination detected 128 benign lesions and 54 malignant lesions. By ultrasound real-time tissue elastography examination, there were 121 benign tumors and 61 malignant tumors. For the benign tumors, the elasticity imaging score was 1.74±0.81, and the elastic strain rate ratio was 1.83±1.22; for the malignant tumors, the elasticity imaging score was 4.45±0.59, and the elastic strain rate ratio was 8.68±5.58. The 182 breast lumps were all removed by surgical resection, and the pathologic examination showed there were 121 benign lesions and 61 malignant lesions. The accuracy, sensitivity and specificity of conventional ultrasonic diagnosis of breast malignant lesions was 76.4%, 59.0% and 85.1%, respectively; while the indexes of ultrasound real-time tissue elastography diagnosis of breast malignant lesions was 96.7%, 95.1% and 97.5%, respectively, and the differences were statistically significant (P<0.05).ConclusionReal-time tissue elastography is helpful in the differential diagnosis between malignant and benign breast lesions.

    Release date:2017-07-21 03:43 Export PDF Favorites Scan
  • Diagnostic value of ultrasonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer: a systematic review

    ObjectiveTo systematically review the diagnostic value of the ultrasonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer.MethodsWe electronically searched the databases including The Cochrane Library, PubMed, CNKI, WanFang Data, VIP, MedaLink and CBM for studies about diagnostic value of the ultrasonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer from inception to October 2016. Two reviewers independently screened literature, extracted data and assessed the risk of bias of the included studies. Then meta-analysis was performed using MetaDisc 1.4 software.ResultsA total of 9 studies involving 735 lymph nodes were included. The results of meta-analysis showed that, the pooled sensitivity, pooled specificity, pooled positive likelihood ratio, pooled negative likelihood ratio and DOR were 0.82 (95%CI 0.78 to 0.86), 0.76 (95%CI 0.72 to 0.81), 3.32 (95%CI 2.57 to 4.27), 0.25 (95%CI 0.20 to 0.31), and 14.77 (95%CI 10.20 to 21.38), respectively. The AUC of the SROC curve was 0.8741.ConclusionUltrasonographic elastography has high sensitivity and specificity in the differential diagnosis of axillary lymph nodes in breast cancer, which indicates that it can be used to diagnosis axillary lymph nodes in breast cancer.

    Release date:2017-08-17 10:28 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content