west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "electrocardiogram signal" 12 results
  • An Improved Wavelet Threshold Algorithm for ECG Denoising

    Due to the characteristics and environmental factors, electrocardiogram (ECG) signals are usually interfered by noises in the course of signal acquisition, so it is crucial for ECG intelligent analysis to eliminate noises in ECG signals. On the basis of wavelet transform, threshold parameters were improved and a more appropriate threshold expression was proposed. The discrete wavelet coefficients were processed using the improved threshold parameters, the accurate wavelet coefficients without noises were gained through inverse discrete wavelet transform, and then more original signal coefficients could be preserved. MIT-BIH arrythmia database was used to validate the method. Simulation results showed that the improved method could achieve better denoising effect than the traditional ones.

    Release date: Export PDF Favorites Scan
  • Removal Algorithm of Power Line Interference in Electrocardiogram Based on Morphological Component Analysis and Ensemble Empirical Mode Decomposition

    Electrocardiogram (ECG) signals are susceptible to be disturbed by 50 Hz power line interference (PLI) in the process of acquisition and conversion. This paper, therefore, proposes a novel PLI removal algorithm based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD). Firstly, according to the morphological differences in ECG waveform characteristics, the noisy ECG signal was decomposed into the mutated component, the smooth component and the residual component by MCA. Secondly, intrinsic mode functions (IMF) of PLI was filtered. The noise suppression rate (NSR) and the signal distortion ratio (SDR) were used to evaluate the effect of de-noising algorithm. Finally, the ECG signals were re-constructed. Based on the experimental comparison, it was concluded that the proposed algorithm had better filtering functions than the improved Levkov algorithm, because it could not only effectively filter the PLI, but also have smaller SDR value.

    Release date: Export PDF Favorites Scan
  • Design of Electrocardiogram Signal Generator Based on Typical Electrocardiogram Database

    Using LabVIEW programming and highspeed multifunction data acquisition card PCI6251, we designed an electrocardiogram (ECG) signal generator based on Chinese typical ECG database. When the ECG signals are given off by the generator, the generator can also display the ECG information annotations at the same time, including waveform data and diagnostic results. It could be a useful assisting tool of ECG automatic diagnose instruments.

    Release date: Export PDF Favorites Scan
  • Study on Electrocardiogram Signal De-noising Methods Based on Ensemble Empirical Mode Decomposition Decomposed by White Noise

    Ensemble empirical mode decomposition (EEMD) is an effective method for non-stationary signal analysis, such as electrocardiogram (ECG) signals. However, the precision and correctness of EEMD are affected by the two parameters, ratio of the added noise and ensemble number. The values of two parameters are set relying on experience and lacking of adaptability for uncertain signals. In order to solve these problems, we proposed a method based on white noise decomposed by EEMD in the present study shown in this paper. Empirical mode decomposition (EMD) was applied to decompose the signal to different intrinsic mode functions (IMFs) in the de-noising process. The white noise IMFs were selected to constitute high frequency part based on the character that the product of the energy density of white noise and its average period tended to be a constant. Then the two parameters of EEMD were adaptively obtained according to the criterion which was used to avoid modal aliasing. Experimental results showed that the method was an effective one for ECG signal de-noising.

    Release date: Export PDF Favorites Scan
  • Study on Non-invasive Detection of Atherosclerosis Based on Electrocardiogram and Pulse Wave Signals

    Artery stiffness is a main factor causing the various cardiovascular diseases in physiology and pathology. Therefore, the development of the non-invasive detection of arteriosclerosis is significant in preventing cardiovascular problems. In this study, the characterized parameters indicating the vascular stiffness were obtained by analyzing the electrocardiogram (ECG) and pulse wave signals, which can reflect the early change of vascular condition, and can predict the risk of cardiovascular diseases. Considering the coupling of ECG and pulse wave signals, and the association with atherosclerosis, we used the ECG signal characteristic parameters, including RR interval, QRS wave width and T wave amplitude, as well as the pulse wave signal characteristic parameters (the number of peaks, 20% main wave width, the main wave slope, pulse rate and the relative height of the three peaks), to evaluate the samples. We then built an assessment model of arteriosclerosis based on Adaptive Network-based Fuzzy Interference System (ANFIS) using the obtained forty sets samples data of ECG and pulse wave signals. The results showed that the model could noninvasively assess the arteriosclerosis by self-learning diagnosis based on expert experience, and the detection method could be further developed to a potential technique for evaluating the risk of cardiovascular diseases. The technique will facilitate the reduction of the morbidity and mortality of the cardiovascular diseases with the effective and prompt medical intervention.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • Research and design for optimal position of electrocardio-electrodes in monitoring clothing for men

    In order to reduce the mortality rate of cardiovascular disease patients effectively, improve the electrocardiogram (ECG) accuracy of signal acquisition, and reduce the influence of motion artifacts caused by the electrodes in inappropriate location in the clothing for ECG measurement, we in this article present a research on the optimum place of ECG electrodes in male clothing using three-lead monitoring methods. In the 3-lead ECG monitoring clothing for men we selected test points. Comparing the ECG and power spectrum analysis of the acquired ECG signal quality of each group of points, we determined the best location of ECG electrodes in the male monitoring clothing. The electrode motion artifacts caused by improper location had been significantly improved when electrodes were put in the best position of the clothing for men. The position of electrodes is crucial for ECG monitoring clothing. The stability of the acquired ECG signal could be improved significantly when electrodes are put at optimal locations.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • An echo state network algorithm based on recursive least square for electrocardiogram denoising

    Electrocardiogram (ECG) is easily submerged in noise of the complex environment during remote medical treatment, and this affects the intelligent diagnosis of cardiovascular diseases. Considering this situation, this paper proposes an echo state network (ESN) denoising algorithm based on recursive least square (RLS) for ECG signals. The algorithm trains the ESN through the RLS method, and can automatically learn the deep nonlinear and differentiated characteristics in the noisy ECG data, and then the network can use these characteristic to separate out clear ECG signals automatically. In the experiment, the proposed method is compared with the wavelet transform with subband dependent threshold and the S-transform method by evaluating the signal-to-noise ratio and root mean square error. Experimental results show that the denoising accuracy is better and the low frequency component of the signal is well preserved. This method can effectively filter out complex noise and effectively preserve the effective information of ECG signals, which lays a foundation for the recognition of ECG signal feature waveform and the intelligent diagnosis of cardiovascular disease.

    Release date:2018-08-23 05:06 Export PDF Favorites Scan
  • Research progress on fabric electrode technologies for electrocardiogram signal acquisition

    In recent years, wearable devices grew up gradually and developed increasingly. Aiming at the problems of skin sensibility and the change of electrode impedance of Ag/AgCl electrode in the process of long-term electrocardiogram (ECG) signal monitoring and acquisition, this paper discussed in detail a new sensor technology–fabric electrode, which is used for ECG signal acquisition. First, the concept and advantages of fabric electrode were introduced, and then the common substrate materials and conductive materials for fabric electrode were discussed and evaluated. Next, we analyzed the advantages and disadvantages from the aspect of textile structure, putting forward the evaluation system of fabric electrode. Finally, the deficiencies of fabric electrode were analyzed, and the development prospects and directions were prospected.

    Release date:2018-10-19 03:21 Export PDF Favorites Scan
  • Study on the quality evaluation of electrocardiogram signal in wearable physiological monitoring system

    As a novel technology, wearable physiological parameter monitoring technology represents the future of monitoring technology. However, there are still many problems in the application of this kind of technology. In this paper, a pilot study was conducted to evaluate the quality of electrocardiogram (ECG) signals of the wearable physiological monitoring system (SensEcho-5B). Firstly, an evaluation algorithm of ECG signal quality was developed based on template matching method, which was used for automatic and quantitative evaluation of ECG signals. The algorithm performance was tested on a randomly selected 100 h dataset of ECG signals from 100 subjects (15 healthy subjects and 85 patients with cardiovascular diseases). On this basis, 24-hour ECG data of 30 subjects (7 healthy subjects and 23 patients with cardiovascular diseases) were collected synchronously by SensEcho-5B and ECG Holter. The evaluation algorithm was used to evaluate the quality of ECG signals recorded synchronously by the two systems. Algorithm validation results: sensitivity was 100%, specificity was 99.51%, and accuracy was 99.99%. Results of controlled test of 30 subjects: the median (Q1, Q3) of ECG signal detected by SensEcho-5B with poor signal quality time was 8.93 (0.84, 32.53) minutes, and the median (Q1, Q3) of ECG signal detected by Holter with poor signal quality time was 14.75 (4.39, 35.98) minutes (Rank sum test, P=0.133). The results show that the ECG signal quality algorithm proposed in this paper can effectively evaluate the ECG signal quality of the wearable physiological monitoring system. Compared with signal measured by Holter, the ECG signal measured by SensEcho-5B has the same ECG signal quality. Follow-up studies will further collect physiological data of large samples in real clinical environment, analyze and evaluate the quality of ECG signals, so as to continuously optimize the performance of the monitoring system.

    Release date:2021-04-21 04:23 Export PDF Favorites Scan
  • A fetal electrocardiogram signal extraction method based on long short term memory network optimized by genetic algorithm

    Fetal electrocardiogram signal extraction is of great significance for perinatal fetal monitoring. In order to improve the prediction accuracy of fetal electrocardiogram signal, this paper proposes a fetal electrocardiogram signal extraction method (GA-LSTM) based on genetic algorithm (GA) optimization with long and short term memory (LSTM) network. Firstly, according to the characteristics of the mixed electrocardiogram signal of the maternal abdominal wall, the global search ability of the GA is used to optimize the number of hidden layer neurons, learning rate and training times of the LSTM network, and the optimal combination of parameters is calculated to make the network topology and the mother body match the characteristics of the mixed signals of the abdominal wall. Then, the LSTM network model is constructed using the optimal network parameters obtained by the GA, and the nonlinear transformation of the maternal chest electrocardiogram signals to the abdominal wall is estimated by the GA-LSTM network. Finally, using the non-linear transformation obtained from the maternal chest electrocardiogram signal and the GA-LSTM network model, the maternal electrocardiogram signal contained in the abdominal wall signal is estimated, and the estimated maternal electrocardiogram signal is subtracted from the mixed abdominal wall signal to obtain a pure fetal electrocardiogram signal. This article uses clinical electrocardiogram signals from two databases for experimental analysis. The final results show that compared with the traditional normalized minimum mean square error (NLMS), genetic algorithm-support vector machine method (GA-SVM) and LSTM network methods, the method proposed in this paper can extract a clearer fetal electrocardiogram signal, and its accuracy, sensitivity, accuracy and overall probability have been better improved. Therefore, the method could extract relatively pure fetal electrocardiogram signals, which has certain application value for perinatal fetal health monitoring.

    Release date:2021-06-18 04:50 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content