west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "fracture reduction" 11 results
  • Design and clinical application of a new extracorporeal reduction device for percutaneous pedicle screw fixation in treatment of thoracolumbar fractures

    Objective To design a new extracorporeal reduction device for percutaneous pedicle screw fixation of thoracolumbar fractures (short for “new reduction device”), and to evaluate its effectiveness. Methods According to the mechanism of thoracolumbar fractures and biomechanics characteristic of reduction, a new reduction device was designed and used in a combination with long U-shaped hollow pedicle screw system. Between January 2014 and January 2016, 36 patients (group A) with single segment thoracolumbar fracture without neurological complications underwent percutaneous pedicle screw fixation, and the clinical data were compared with those of another 39 patients (group B) with thoracolumbar fracture underwent traditional open pedicle screw fixation. There was no significant difference in gender, age, cause of injury, classification of fractures, segments of fractures, injury to operation interval, height percentage of injury vertebrae, and kyphotic angle between 2 groups (P>0.05). The 2 groups were compared in terms of operation time, length of incision, intraoperative blood loss, drainage volume, visual analogue scale (VAS) at postoperative 24 hours, fluoroscopy frequency, ambulation time, height percentage of injury vertebrae, kyphotic angle and correction. Results Group A was significantly better than group B in the operation time, length of incision, intraoperative blood loss, drainage volume, VAS score at postoperative 24 hours, and ambulation time (P<0.05). However, fluoroscopy frequency of group B was significantly less than that of group A (P<0.05). All patients were followed up 11.2 months on average (range, 7-15 months). There was no intraoperative and postoperative complications of iatrogenic nerve injury, infection, breakage of internal fixation. Mild pulling-out of pedicle screws occurred in 1 case of group A during operation. The kyphotic angle and height percentage of the fractured vertebral body were significantly improved at 3 days after operation when compared with preoperative ones (P<0.05), but no significant difference was found between 2 groups at 3 days after operation (P>0.05). Conclusion Minimally invasive extracorporeal reduction device for percutaneous pedicle screw fixation is an effective and safe treatment of thoracic vertebrae and lumbar vertebrae fractures, because of little trauma, less bleeding, and quicker recovery.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
  • The measurement and clinical significance of the rotation angles of head-neck fragments after cephalomedullary nail fixation in intertrochanteric fractures

    ObjectiveTo measure the rotation angle of the head-neck fragment of intertrochanteric fracture after cephalomedullary nail fixation by three-dimensional CT imaging, and to explore its clinical significance.MethodsThe clinical data of 68 patients with unstable intertrochanteric fracture of AO/Orthopaedic Trauma Association (AO-OTA) type 31-A2 treated with cephalomedullary nail fixation and with complete intraoperative fluoroscopy and postoperative three-dimensional CT imaging data between July 2016 and October 2018 were retrospectively analyzed. Among them, there were 21 males and 47 females, aged 68-93 years, with an average age of 81.8 years. There were 31 cases of AO/OTA type 31-A2.2 and 37 cases of 31-A2.3. Fracture reduction quality was evaluated according to Baumgaertner et al. and Chang et al. criteria. The anteromedial cortical contact or not of each patient was observed by three-dimensional CT imaging on T3DView software after operation. The rotation of head-neck fragments were divided into three types: non-rotation, flexion rotation, and hyperextension rotation. The rotation angles of each type were measured and the relationship between the rotation type of the head-neck fragments and the contact of the anteromedial cortex was analyzed.ResultsThe reduction and fixation of the small trochanter were not performed in 68 patients. According to Baumgaertner et al. criteria, the quality of fracture reduction was excellent in 15 cases (22.1%), acceptable in 50 cases (73.5%), and poor in 3 cases (4.4%). According to Chang et al. criteria, 31 cases were excellent (45.6%), 33 cases were acceptable (48.5%), and 4 cases were poor (5.9%). Thirty-nine cases (57.4%) received anteromedial cortical support and 29 cases (42.6%) did not receive cortical support. Three-dimensional CT imaging showed non-rotation in 12 cases (17.6%), flexion rotation in 39 cases (57.4%), and hyperextension rotation in 17 cases (25.0%). There were 7 cases (58.3%), 30 cases (76.9%), and 2 cases (11.8%) of cortical support in non-rotation group, flexion rotation group, and hyperextension rotation group, respectively. The rotation angles were (1.05±0.61), (13.96±6.17), (8.21±3.88)°, respectively. There were significant differences between groups (P<0.05).ConclusionIn the unstable intertrochanteric fracture after cephalomedullary nail fixation, the rotation of head-neck fragment exists in most patients, and the types of flexion rotation and non-rotation can easily obtain cortical support reduction.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • Research progress on anteromedial cortical positive support reduction in treatment of intertrochanteric fracture

    ObjectiveTo introduce the reduction concept of anteromedial cortical support in the treatment of intertrochanteric fracture, summarize the history, characteristics, biomechanics, and clinical applications, discuss the unsolved problems and prospect the future directions.MethodsRelevant domestic and foreign studies on cortical support reduction of intertrochanteric fracture in recent years were reviewed. Conclusions were drawn combined with clinical experience.ResultsThe positive cortical supportive reduction of intertrochanteric fracture, as a stable non-anatomical fracture reduction technique, has dual effects on mechanical buttress and biological bone healing. It does not increase the difficulty of doctors’ surgical procedure. For patients, it decreases the loss of femoral neck length, the loss of neck-shaft angle, the incidence rate of coxa vara, and maintains stable mechanical structure of the pelvis. It also shows a lower rate of instrument-related complications, and higher limb function scores. The mechanical stability of medial cortex apposition is more important than that of anterior cortex. For the best stability of the fracture, both sides should get positive support reduction pattern.ConclusionAnteromedial cortical support reduction can improve the postoperative stability of intertrochanteric fracture, enable better imaging and functional prognosis. As a kind of non-anatomic form of functional reduction, it can be used as a suboptimal choice secondary to anatomic reduction.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • Concept evolution and research progress of stability reconstruction for intertrochanteric fracture

    ObjectiveTo summarize the evolving concept and research progress on stability reconstruction in the surgical treatment of intertrochanteric fracture.MethodsRelated literature and author’s own experience concerning the surgical treatment of intertrochanteric fracture were reviewed and analyzed in terms of fracture pathoanatomy, stable and unstable pattern, adequate and in-adequate reduction, primary and secondary stability, postoperative stability evaluation, and early weight-bearing.ResultsIntertrochanteric fracture occur at the translational area of cervico-trochanteric junction, which has a nature tendency to varus instability. Fracture reduction quality is the paramount factor and is evaluated by two views, the anteroposterior and lateral Garden alignment and cortex apposition between the head-neck fragment and the femoral shaft. Rather than the posteromedial lesser trochanteric frag ment, the cortical support concept (positive, neutral, negative) emphasizes the reduction of anteromedial cortex to a nonanatomic positive apposition or an " anatomic” neutral apposition in intraoperative fluoroscopy. Postoperative radiographic stability score provides a quantitative assessment for early weight-bearing standing and walking. However, some fractures may lose cortical contact and buttress (negative) during the process of postoperative telescoping and secondary stability. Further studies are needed to elucidate the risk factors such as tilting, swing or rotation of the head-neck fragment, and propose new preventive methods.ConclusionStability reconstruction of intertrochanteric fracture requires adequate fracture reduction with Garden alignment and anteromedial cortical support apposition, and reliable sustainment by internal fixation implants. Early weight-bearing standing and walking is safe in patients with perfect postoperative stability score.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • Application of modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column

    ObjectiveTo explore effectiveness of reduction and internal fixation via modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column.MethodsBetween January 2016 and September 2018, 19 patients diagnosed as tibial plateau fractures involving posterolateral column were treated with reduction and internal fixation via modified anterolateral supra-fibular-head approach. There were 11 males and 8 females with an average age of 43.2 years (range, 28-65 years). The causes of tibial fracture were traffic accident (12 patients), falling injury (5 patients), and falling from height (2 patients). According to the Schatzker typing, the tibial fractures were rated as type Ⅱ in 9 cases, type Ⅲ in 4 cases, type Ⅴ in 4 cases, and type Ⅵ in 2 cases. The time from injury to operation was 5-13 days (mean, 8.5 days). There were 2 patients with osteoporosis. The operation time, intraoperative blood loss, and postoperative complications were recorded. The knee X-ray film was reviewed regularly to observe the fracture healing. At last follow-up, the fracture reductions were evaluated by Rasmussen radiological score. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score system.ResultsThe average operation time was 95 minutes (range, 65-130 minutes). The average intraoperative blood loss was 220 mL (range, 150-350 mL). All incisions healed by first intention. No complications such as infection or deep venous thrombosis occurred. All patients were followed up 12-20 months (mean, 15.4 months). X-ray films showed that the fractures healed with the healing time of 12-20 weeks (mean, 14.5 weeks). No complications such as loosening or breakage of internal fixation occurred. At last follow-up, according to the Rasmussen radiological score, the fracture reductions were evaluated as excellent in 13 cases, good in 4 cases, fair in 1 case, and poor in 1 case. HSS scores of knee joint function were excellent in 14 cases, good in 3 cases, fair in 1 case, and poor in 1 case. The knee joint range of motion was 90°-135°, with an average of 113.4°.ConclusionApplication of modified anterolateral supra-fibular-head approach in reduction and internal fixation for tibial plateau fractures involving posterolateral column has the advantages of full exposure, less trauma, safety, and reliable reduction and fixation.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Clinical application of disc reduction and anchorage for diacapitular condylar fracture with disc displacement

    Objective To investigate the effectiveness of disc reduction and anchorage in treatment of diacapitular condylar fracture with disc displacement. Methods Between June 2019 and June 2021, 20 patients (27 sides) with diacapitular condylar fractures with disc displacement were treated with disc reduction and anchorage combined with internal fixation. There were 15 males and 5 females with a median age of 40 years (range, 8-65 years). The fractures were caused by falling from height in 3 cases, traffic accident in 3 cases, and falling in 14 cases. Among them, there were 13 cases of unilateral fracture and 7 cases of bilateral fractures. Five sides were type A fractures and 22 sides were type B. There were 14 simple diacapitular condylar fractures, 12 diacapitular condylar fractures combined with mandibular chin fractures, and 1 diacapitular condylar fracture combined with mandibular angle fracture. The maximum opening was 5-20 mm (mean, 9.7 mm). The time from injury to operation was 4-20 days, with an average of 11.6 days. The postoperative imaging examination was performed to evaluate the reduction of fracture and disc. The maximum opening at 6 months after operation was recorded, and the clinical dysfunction index (Di) of Helkimo index was used to evaluate the temporomandibular joint function. Results All incisions healed by first intention. All 20 patients were followed up 6-10 months (mean, 8 months). Postoperative imaging examination showed that 27 fractures were well reduced, of which 26 were anatomically reduced and 1 was basically reduced; the reduction of the temporomandibular joint disc was excellent in 25 sides, good in 1 side, and poor in 1 side, and the effective rate of disc reduction and anchorage was 96.3%. The occlusion relationship of the patient was stable and basically reached the pre-injury level, the incision scar was hidden, and the mouth opening significantly improved when compared with the preoperative level. The maximum mouth opening was 32-40 mm (mean, 36.8 mm) at 6 months after operation. Maximum opening was more than 35 mm in 17 cases. At last follow-up, joint function reached Di 0 grade in 8 sides, DiⅠ grade in 18 sides, and DiⅡ grade in 1 side. After operation, 2 cases of opening deviation, 1 case of joint click, and 2 cases of temporary disappearance of frontal striae on affected side occurred, which recovered to normal after symptomatic treatment. ConclusionFor diacapitular condylar fractures with disc displacement, it is necessary to adopt disc reduction and anchorage at the same time of fracture reduction and internal fixation, which can achieve good clinical results.

    Release date: Export PDF Favorites Scan
  • Development and clinical application of robot-assisted technology in traumatic orthopedics

    ObjectiveTo review and evaluate the basic principles and advantages of orthopedic robot-assisted technology, research progress, clinical applications, and limitations in the field of traumatic orthopedics, especially in fracture reduction robots. Methods An extensive review of research literature on the principles of robot-assisted technology and fracture reduction robots was conducted to analyze the technical advantages and clinical efficacy and shortcomings, and to discuss the future development trends in this field. Results Orthopedic surgical robots can assist orthopedists in intuitive preoperative planning, precise intraoperative control, and minimally invasive operations. It greatly expands the ability of doctors to evaluate and treat orthopedic trauma. Trauma orthopedic surgery robot has achieved a breakthrough from basic research to clinical application, and the preliminary results show that the technology can significantly improve surgical precision and reduce surgical trauma. However, there are still problems such as insufficient evaluation of effectiveness, limited means of technology realization, and narrow clinical indications that need to be solved. ConclusionRobot-assisted technology has a broad application prospect in traumatic orthopedics, but the current development is still in the initial stage. It is necessary to strengthen the cooperative medical-industrial research, the construction of doctors’ communication platform, standardized training and data sharing in order to continuously promote the development of robot-assisted technology in traumatic orthopedics and better play its clinical application value.

    Release date: Export PDF Favorites Scan
  • Treatment of femoral neck fractures with closed reduction assisted by joystick technique and cannulated screw fixation

    Objective To investigate the effectiveness of joystick technique assisted closed reduction and cannulated screw fixation in the treatment of femoral neck fracture. Methods Seventy-four patients with fresh femoral neck fractures who met the selection criteria between April 2017 and December 2018 were selected and divided into observation group (36 cases with closed reduction assisted by joystick technique) and control group (38 cases with closed manual reduction). There was no significant difference in gender, age, fracture side, cause of injury, Garden classification, Pauwels classification, time from injury to operation, and complications (except for hypertension) between the two groups (P>0.05). The operation time, intraoperative infusion volume, complications, and femoral neck shortening were recorded and compared between the two groups. Garden reduction index was used to evaluate the effect of fracture reduction, and score of fracture reduction (SFR) was designed and was used to evaluate the subtle reduction effect of joystick technique. ResultsThe operation was successfully completed in both groups. There was no significant difference in operation time and intraoperative infusion volume between the two groups (P>0.05). All patients were followed up 17-38 months, with an average of 27.7 months. Two patients in the observation group received joint replacement due to failure of internal fixation during the follow-up, and the other patients had fracture healing. Within 1 week after operation, the Garden reduxtion index of the observation group was better than the control group; the SFR score of the observation group was also higher than that of the control group; the proportion of femoral neck shortening within 1 week after operation and at 1 year after operation in the observation group were lower than those in the control group. The differences of the above indexes between the two groups were significant (P<0.05). ConclusionThe joystick technique can improve the effectiveness of closed reduction of femoral neck fractures and reduce the incidence of femoral neck shortening. The designed SFR score can directly and objectively evaluate the reduction effect of femoral neck fracture.

    Release date: Export PDF Favorites Scan
  • Study on effectiveness of treating femoral neck fractures based on theory of “positive support”

    Objective To explore effectiveness of positive support reduction and internal fixation in the treatment of femoral neck fractures. Methods A clinical data of 74 patients with femoral neck fractures treated with hollow screw internal fixation between September 2017 and September 2021 was retrospectively analyzed. Based on the quality of fracture reduction, they were divided into positive support reduction group (group A, n=25), negative support reduction group (group B, n=21), and anatomical reduction group (group C, n=28). There was no significant difference in baseline data such as gender, age, cause of injury, disease duration, fracture side, Garden classification, and fracture line position classification between groups (P>0.05). The occurrence of complications such as early fixation failure, femoral neck shortening, non-union of fractures, and femoral head necrosis in three groups, as well as the Harris score of the hip joint were recorded and compared. Results All patients had primary healing of incisions after operation and were followed up more than 12 months. The follow-up time for groups A, B, and C was (21.1±5.7), (22.6±4.3), and (21.9±4.1) months, respectively; there was no significant difference between groups (P>0.05). There was no significant difference in the incidences of non-union of fractures, early internal fixation failure, and the femoral head necrosis between groups (P>0.05). The incidence and length of femoral neck shortening, and the hip Harris score at last follow-up in groups A and C were all superior to those in the group B, with significant difference (P<0.05). There was no significant difference in the above indicators between groups A and C (P>0.05). Conclusion Positive support reduction can provide a good biomechanical environment for the healing of femoral neck fractures, thereby achieving a higher fracture healing rate, reducing the occurrence of femoral neck shortening, minimizing the function of hip joint, and achieving effectiveness similar to anatomical reduction.

    Release date: Export PDF Favorites Scan
  • Morphological characteristics and reduction techniques of sagittal beak-like deformity of head-neck fragment in femoral intertrochanteric fractures

    Objective To summarize the morphological characteristics of sagittal beak-like deformity of head-neck fragment in femoral intertrochanteric fractures and to investigate the technical skills in fracture reduction. Methods A clinical data of 31 patients with femoral intertrochanteric fractures between May 2021 and April 2023 was retrospectively analyzed. The fractures had sagittal beak-like deformity of head-neck fragment in all patients. There were 13 males and 18 females, with an average age of 76.2 years (range, 68-83 years). The time from injury to operation was 36-76 hours (mean, 51.2 hours). Fractures were classified as type A1.2 in 10 cases, type A1.3 in 11 cases, type A2.2 in 6 cases, and type A2.3 in 4 cases according to the AO/Orthopaedic Trauma Association (AO/OTA)-2018 classification; and as type A1.3 in 10 cases, type A2.1 in 11 cases, type A2.2 in 6 cases, type A2.3 in 2 cases, and type A2.4 in 2 cases according to a novel comprehensive classification for femoral intertrochanteric fractures proposed by the “Elderly Hip Fracture” Research Group of the Reparative and Reconstructive Surgery Committee of the Chinese Rehabilitation Medical Association. Based on preoperative X-ray films, CT scan and three-dimensional reconstruction, the fractures were classified into two types: type 1 (14 cases), with uncomplicated fracture morphology, severe bone interlocking and (or) soft tissue incarceration; type 2 (17 cases), with severe fracture crushing, obvious dissociation between bone blocks, and severe soft tissue hinge destruction. After the failure of the closed reduction, all patients underwent fracture reduction assisted with instrument via anterior minimal incision and proximal femoral nail antirotation nails internal fixation. The operation time, intraoperative fluoroscopy, intraoperative visible blood loss, length of hospital stay, and incidence of complications were recorded. The fracture reduction quality and stability score were assessed at immediate after operation under fluoroscopy. The fracture healing was evaluated and healing time was recorded by X-ray films. The pain visual analogue scale (VAS) score was performed at 48 hours after operation and Parker-Palmer activity score at 3 months after operation for function evaluation. ResultsThe operation time was 39-58 minutes (mean, 46.3 minutes); fluoroscopy was performed 13-38 times (mean, 23.5 times) during operation; the intraoperative visible blood loss was 45-90 mL (mean, 65.3 mL). The fracture reduction quality and stability score were rated as good in 29 cases and acceptable in 2 cases. The pain VAS score was 2-6 (mean, 3.1) at 48 hours after operation. Eleven patients developed deep vein thrombosis of the lower limbs after operation. Patients were hospitalized for 6-10 days (mean, 7.3 days). All patients were followed up 5-8 months (mean, 6.5 months). All fractures healed at 3.5-8.0 months after operation (mean, 4.5 months). Parker-Palmer activity score at 3 months after operation was 9 in 28 cases and 6 in 3 cases. Conclusion The femoral intertrochanteric fracture with sagittal beak-like deformity of head-neck fragment is difficult to manually reduce. The pin combined with cannulated screw insertion to the neck cortex can hold the fragment and assist fracture reduction, which is a simple and effective technique.

    Release date:2024-06-14 09:52 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content