Objective To explore the correlation between liver volume variation of posthepatitic cirrhosis patients and the severity of the disease. Methods One hundred and eleven patients with normal livers and 74 posthepatitic cirrhosis patients underwent volume CT scan. The relation between normal liver volume and body height, body weight and body surface area was studied by linear regression and correlation method, the standard liver volume equation was deduced. The change ratio of liver volume in cirrhotic patients was calculated and compared with Child classification. Results The mean normal liver volume of Chinese adults was (1 225.15±216.23) cm3, there was a positive correlation between liver volume and body height, body weight 〔liver volume (cm3)=12.712×body weight (kg)+450.44〕 and body surface area 〔liver volume (cm3)=876.02×body surface area (m2)-297.17〕. The mean liver volume of Child A, B and C patients were (1 077.77±347.01) cm3, (1 016.35±348.60) cm3 and (805.73±208.85) cm3 respectively. The liver volume and liver volume index was significantly smaller in Child C patients than those in Child A and B patients (P<0.05); while liver volume change ratio was higher in Child C patients (P<0.05). Conclusion Liver volume variation of cirrhotic patients can be quantitatively assessed by 16 slices helical CT volume measurement and standard liver volume equation. The change of the liver volume is correlated with the severity of liver cirrhosis.
Objective To investigate the use of intraoperative transit time flow measurement (TTFM) to accuratelyevaluate graft patency during sequential coronary artery bypass grafting (CABG). Methods Clinical data of 131 patientsundergoing sequential off-pump coronary artery bypass grafting (OPCAB) with the great saphenous vein (with or without internal mammary artery) as graft vessels in Beijing Anzhen Hospital from April 2012 to January 2013 were retrospectivelyanalyzed. There were 92 male and 39 female patients with their age of 61.35±8.24 years. During the operation,2 methods were used to measure mean blood flow volume,pulsatility index (PI) and diastolic filling (DF) of the graft vessels. For thenon-blocking method,blood flow in graft vessels was maintained,and TTFM was applied 2 cm proximal to the anastomoticsite in graft vessels to record above parameters. For the blocking method,blood flow in graft vessels was temporally blockedby clipping distal graft vessels with an atraumatic bulldog clamp,and TTFM was applied 2 cm proximal to the anastomotic site in graft vessels to record above parameters. Results Blood flow volumes of the diagonal branch (27.43±15.22 ml/minvs. 59.28±30.13 ml/min),obtuse marginal branch (26.14±19.74 ml/min vs. 47.19±24.27 ml/min) and posterior left ventr-icular branch (19.16±8.92 ml/min vs. 38.83±20.11 ml/min) measured by the blocking method were significantly smallerthan those measured by the non-blocking method (P<0.05) . PI values of the diagonal branch (2.93±1.30 vs. 2.31±0.91),obtuse marginal branch (2.62±1.17 vs. 2.01±0.87) and posterior left ventricular branch (2.33±0.92 vs. 1.80±0.73) meas-ured by the blocking method were significantly higher than those measured by the non-blocking method (P<0.05). There was no statistical difference in DF values measured by 2 methods at respective anastomotic sites,and all DF values were higher than 50%. Non-blocking method identified 1 anastomotic site and blocking method identified 3 anastomotic sites that were not patent,and these anastomotic sites became patent after graft reconstruction. Conclusion Blood flow velocity of sequential grafts is higher than that of single grafts,indicating that sequential grafts have the advantages of high blood flow volume and low risk of thrombosis. Blocking method can more accurately evaluate graft patency at the anastomotic sites and sensitively identify graft vessels that are not patent,which is helpful for anastomotic site reconstruction in time and enhancement of successful rate of CABG.
Objective To summarize the clinical application of esophagogastrostomy with layered anastomosis and to observe the healing quality of anastomotic stoma in animal experiments. Methods One thousand and twenty-four patients suffered from carcinoma of esophagus or carcinoma of gastric cardia had undergone esophagogastrostomy by layered anastomosis with absorbable suture. Twenty-four experimental dogs (adult male healthy hybrid dogs) were divided into two groups: the experimental group and the control group. The former (experimental group) underwent the layered anastomosis, the diameter of esophagogastric stoma and the length and depth of stomal scar were measured under anesthesia in both groups on 5th,8th,14th,and 42th postoperative day, respectively. So were done the histological measurement, such as the count infiltrating inflammatory cells, the proliferation of blood capillary and other cells. And the cytokines related to wound healing (LsAB technique) such as epidermal growth factor(EGF), transforming growth factor-beta 1 (TGF-beta 1) were detected, either. Results One thousand and twenty-four patients had no anastomotic leakage. There were only 6 patients suffered from mild anastomotic stricture, and they got well after one dilatation. The results of the measurement of 24 experimental dogs revealed that, in the experimental group, the mucosa was in good connecting condition, had a soften anastomotic stoma and a thin scar. The counts of inflammatory cells and fibroblast showed more in number at the early time after operation (Plt;0.05), while showed less in number at the advanced time of operation (Plt;0.05). In the control group, however, the mucosa were in a bad connecting condition, the scar was thicker, and the muscle layer was frequently exposed. The counts of inflammatory cells and fibroblast were fewer at the early time after operation, however, they had a clearly tendency of increasing at the anaphase after the operation. On the cytokines related to the healing of wound in the experimental group, there was a high expression and activity at the early period. There were a little expression up to postoperative 42 d. Whereas, in the control group, there had a low expression level,increased clearly on postoperative 8 d, and still a higher expression up to postoperative 42 d. Conclusions The esophagogastrostomy by layered anastomosis has a high healing quality with a thin scar. The proliferation of cells and the expression of growth factors benefits the normal healing of wound by first intention.
Objective To study the relation between competitive flow and graft flow in coronary artery bypass grafting. Methods Twelve adult healthy dogs (weighing 27. 62 ± 1. 63 kg) were anesthetized and received offpump coronary artery bypass grafting. During operation, flow meter was used to measure the degree of stenosis, and according to which four groups were classified. They were: non-stenosis group, 33% stenosis group, 50% stenosis group and 75 % stenosis group. Hemodynamic parameters including flow volume of graft, pulsatility indes (PI), heart rate(HR) and mean arterial pressure(MAP) were recorded with or without competitive flow. Results When there was a competitive flow, the flow volume of graft in all four groups was less than the flow volume of graft which has not been affected by competitive flow. PI of non-stenosis group and 33% stenosis group was lower than normal PI. 50% stenosis group PI decreased from 8. 36±3. 52 to 3. 02±0. 94; 75% stenosis group PI was more than 5. Conclusion Competitive flow will restrain the graft flow. The position of graft anastomosis may be affected graft's patency.
Objective To investigate and analyze the three-dimensional anatomic structure of glenoid bone in some Chinese people so as to provide the accurate anatomic data to design the new prosthesis of glenoid bone for Chinese people. Methods A total of 90 volunteers with two healthy shoulders (52 males and 38 females, aging 19-60 years with an average of 39.6 years) were selected. Five parameters were measured by use of three-dimensional computed tomography, volumerendering technique (VRT) and multiplanar reformation (MPR), including the maximum antero-posterior width (MAPW),antero-posterior radius of curvature (APROC), maximum supero-inferior height (MSIH), supero-inferior radius of curvature(SIROC) and version angle (VA) of glenoid. All parameters were measured two times, and the average values were analysed by SPSS13.0. The level of significance was set at P lt; 0.05. Results The average MAPW was (2.51 ± 0.32) cm, the average APROC was (5.50 ± 1.21) cm, the average MSIH was (3.45 ± 0.29) cm, the average SIROC was (3.98 ± 0.55) cm, and the average VA was (— 0.03 ± 4.66)°. There were no significant differences (P gt; 0.05) in MAPW, APROC, MSIH, SIROC and VA between two sides. There were significant differences (P lt; 0.05) in MAPW, MSIH, SIROC and VA, and no significant difference (P gt; 0.05) in APROC between female and male. MAPW was correlated with APROC, MAPW was correlated with MSIH, APROC was correlated with SIROC, and the correlation coefficient was 0.298, 0.495 and 0.262, respectively. Conclusion There are no significant differences in MAPW, APROC, MSIH, SIROC and VA of glenoid between two sides. There are sexual significant differences in MAPW, MSIH, SIROC and VA. The data and its statistical results may serve as guidel ines for the design of the glenoid component.
To assess the rel iabil ity of diabetic cutaneous ulcer surface area (DCUSA) measurement usingdigital planimetry method (A) and transparency tracing method (B). Methods Images of diabetic cutaneous ulcers from35 inpatients with diabetic skin ulcers from September 2005 to April 2007 were taken by a digital camera once a week or twice a week over a period of 12 weeks, resulting in 305 photographs; the ulcers were traced on a grid with acetate wound tracings, simultaneously. A total of 305 pairs of DCUSA which were calculated respectively throughout digital camera combined with Image J medical imaging software and transparency tracing with grid sheet by two independent observers sequentially were obtained. The intraclass correlation coefficients (ICCs, one-way random effect model) was used as an indicator of chancecorrected agreement to estimate the relative rel iabil ity for the interobserver data. Multiple l inear regression analysis was also used to measure the relationship of these two methods. Results DCUSA obtained from method A and obtained from method B was (4.84 ± 7.73) cm2 and (5.03 ± 7.89) cm2, respectively; no significant difference was found (P gt; 0.05). ICCs was high (ICCs=0.949 for method B and 0.965 for method A), indicating that the relative rel iabil ity for the interobserver was excellent. The method A were highly correlated with measurements obtained from method B (r = 0.957, P lt; 0.05). Conclusion The digital planimetry method described in this study represents a simple, practical, without any wound damage and contamination, and inexpensive technique to accurately evaluate the areas of diabetic cutaneous ulcers. The photographic technique combined with Image J medical imaging software should be considered for wound measurement.
This paper presents the preliminary design of data acquisition system of a portable uroflowmeter. The system uses double-hole cantilever pressure sensor. The signal is transferred to ATmega644PA microprogrammed control unit (MCU), converted by A/D (analog to digital) convertor. Then the further data are processed and get the corresponding relationship of weight-time and two curves of urine flow and urinary flow rate. In the measurement accuracy of the device about urine flow, two factors about the placement and height of the data acquisition are analyzed to show the accuracy of the equipment through the Origin 8.0 data analysis software. The design is characterized by low cost and high speed of data collection, real-time, high accuracy.
Based on the imaging photoplethysmography (iPPG) and blind source separation (BSS) theory the author put forward a method for non-contact heartbeat frequency estimation. Using the recorded video images of the human face in the ambient light with Webcam, we detected the human face through software, separated the detected facial image into three channels RGB components. And then preprocesses i.e. normalization, whitening, etc. were carried out to a certain number of RGB data. After the independent component analysis (ICA) theory and joint approximate diagonalization of eigenmatrices (JADE) algorithm were applied, we estimated the frequency of heart rate through spectrum analysis. Taking advantage of the consistency of Bland-Altman theory analysis and the commercial Pulse Oximetry Sensor test results, the root mean square error of the algorithm result was calculated as 2.06 beat/min. It indicated that the algorithm could realize the non-contact measurement of heart rate and lay the foundation for the remote and non-contact measurement of multi-parameter physiological measurements.
Accurate measurements of voltage and current from electrosurgery are the basis of development of electrosurgery with feedback function. We, therefore, developed a parameter measurement system based on PC, with high voltage and current from electrosurgery being sensed with transformers, amplified, filtered, transformed into single-ended signals, and then into RMS signals. The root mean square (RMS) signals were transformed into digital signals through DAQ card and the data was processed in PC with Labview. The process included sampling, displaying and storage. The experiment results indicated that the measurement system could measure the output parameters from electrosurgery steadily and correctly so that the development of the system has been successful. It can be the basis of development of embedded parameters measurement system and can provide accurate feedback information for intellectual electrosurgery.
Based on repeated experiments as well as continuous researching and improving, an efficient scheme to measure velocity and displacement of the coxa and knee movements based on video image processing technique is presented in this paper. The scheme performed precise and real-time quantitative measurements of 2D velocity or displacement of the coxa and knee using a video camera mounted on one side of the healing and training beds. The beds were based on simplified pinhole projection model. In addition, we used a special-designed auxiliary calibration target, composed by 24 circle points uniformly located on two concentric circles and two straight rods which can rotate freely along the concentric center within the vertical plane, to do the measurements. Experiments carried out in our laboratory showed that the proposed scheme could basically satisfy the requirements about precision and processing speed of such kind of system, and would be very suitable to be applied to smart evaluation/training and healing system for muscles/balance function disability as an advanced and intuitional helping method.