Robot rehabilitation has been a primary therapy method for the urgent rehabilitation demands of paralyzed patients after a stroke. The parameters in rehabilitation training such as the range of the training, which should be adjustable according to each participant’s functional ability, are the key factors influencing the effectiveness of rehabilitation therapy. Therapists design rehabilitation projects based on the semiquantitative functional assessment scales and their experience. But these therapies based on therapists’ experience cannot be implemented in robot rehabilitation therapy. This paper modeled the global human-robot by Simulink in order to analyze the relationship between the parameters in robot rehabilitation therapy and the patients’ movement functional abilities. We compared the shoulder and elbow angles calculated by simulation with the angles recorded by motion capture system while the healthy subjects completed the simulated action. Results showed there was a remarkable correlation between the simulation data and the experiment data, which verified the validity of the human-robot global Simulink model. Besides, the relationship between the circle radius in the drawing tasks in robot rehabilitation training and the active movement degrees of shoulder as well as elbow was also matched by a linear, which also had a remarkable fitting coefficient. The matched linear can be a quantitative reference for the robot rehabilitation training parameters.
Rapid development is undergoing in the field of rehabilitation robots, and more countries (regions) are participating in international cooperation and becoming academic contributors. Here in this study, the bibliometric method is used to determine the dynamics and developments of international cooperation in China. The publication data are indexed in Web of Science with search term of rehabilitation robot from 2000 to 2019. Compared with other countries (regions), publication with international co-authors and institutes participating in international cooperation are studied by assessment of indicators such as the cooperation degree, cooperation frequency, and the frequency of citations. The results show that in the past two decades, international scientific cooperation has shown a positive tendency in China, and participating in international collaboration could improve China’s impact on the global rehabilitation robot. The United States, England and Japan are the top three countries in number of cooperation with China. Our findings provide valuable information for researchers to better understand China’s international scientific collaboration in rehabilitation robot.
In order to study the effect of light with different wavelengths on the motion behavior of carp robots, phototaxis experiment, anatomical experiment, light control experiment and speed measurement experiment were carried out in this study. Blue, green, yellow and red light with different wavelength were used to conduct phototaxis experiments on carp to observe their movement behavior. By dissecting the skull bones of the carp to determine the appropriate location to carry the light control device, we independently developed a light control carrying device which was suitable for any illumination intensity environment. The experiment of the light-controlled carp robots was carried out. The motion behavior of the carp robot was checked by using computer binocular stereo vision technology. The motion trajectory of the carp robot was tracked and obtained by applying kernel correlation filter (KCF) algorithm. The motion velocity of the carp robot at different wavelengths was calculated according to their motion trajectory. The results showed that carps’ sensitivity to different light changed from strong to weak in the order of blue, red, yellow and green, so that using light with different wavelengths to control the speed of the carp robot has certain laws to follow. A new method to avoid brain damage in carp robots control can be provided in this study.
Bionic untethered micro-nano robots, due to their advantages of small size, low weight, large thrust-to-weight ratio, strong wireless mobility, high flexibility and high sensitivity, have very important application values in the fields of biomedicine, such as disease diagnosis, minimally invasive surgery, targeted therapy, etc. This review article systematically introduced the manufacturing methods and motion control, and discussed the biomedical applications of bionic untethered micro-nano robots. Finally, the article discussed the possible challenges for bionic untethered micro-nano robots in the future. In summary, this review described bionic untethered micro-nano robots and their potential applications in biomedical fields.
The application of robots in thoracic surgery is mainly based on the da Vinci general surgery robot. With the popularization of artificial intelligence (AI) application scenarios, the combination of AI and robots is more closely, and there is a strong clinical demand and huge application space for the development of specialized disease-specific robotic systems for thoracic surgery. This article aims to systematically describe the history of the rise of specialized surgical robots and the status of the localization of surgical robots in China, propose the concept of applying AI to the research and development of integrated specialized disease-specific robots in thoracic surgery, and clarify the ethics and prospects that intelligent specialized disease-specific surgical robots will face.
Objective To broaden the current understanding of the usage willingness about artificial intelligence (AI) robots and relevant influence factors for elderly patients. Methods The elderly patients in the inpatient ward, outpatient department and physical examination of the Department of Geriatrics, West China Hospital of Sichuan University were selected by convenient sampling for investigation between February and April 2020, to explore the willingness of elderly patients to use AI robots and related influencing factors. Results A total of 446 elderly patients were included. There were 244 males and 202 females. The willingness to use AI robots was (14.40±3.62) points. There were statistically significant differences among the elderly patients with different ages, marital status, living conditions, educational level, current health status, current vision status, current hearing status, self-care ability and family support in their willingness to use AI robots (P<0.05). Multiple linear regression analysis showed that age, education level and family support were the influencing factors of use intention (P<0.05). Among the elderly patients, 60.76% had heard of AI robots, but only 28.03% knew the medical application of AI robots, and only 13.90% had used AI robot services. Most elderly patients (>60%) thought that some adverse factors may reduce their usage willingness, like “the price is too expensive” and “the use is complex, or I don’t know how to use”. Conclusions Elderly patients’ cognition of AI robots is still at a low level, and their willingness to use AI robots is mainly affected by age, education level and family support. It is suggested to consider the personalized needs of the elderly in terms of different ages, education levels and family support, and promote the cheap and user-friendly AI robots, so as to improve the use of AI robots by elderly patients.
The neural stimulator is a core component of animal robots. While the control effect of animal robots is influenced by various factors, the performance of the neural stimulator plays a decisive role in regulating animal robots. In order to optimize animal robots, embedded neural stimulators had been developed using flexible printed circuit board technology. This innovation not only enabled the stimulator to generate parameter-adjustable biphasic current pulses through control signals, but also optimized its carrying mode, material, and size, overcoming the disadvantages of traditional backpack or head-inserted stimulators, which have poor concealment and are prone to infection. Static, in vitro, and in vivo performance tests of the stimulator demonstrated that it not only had precise pulse waveform output capability, but also was lightweight and small in size. It had excellent in vivo performance in both laboratory and outdoor environments. Our study has high practical significance for the application of animal robots.
Objective To analyze the accuracy of prosthesis size selection in Naton robot-assisted medial unicondyle knee arthroplasty by comparing the actual prosthesis size used during operation and the preoperative planning. Methods The clinical data of 100 patients (110 knees) who underwent Naton robot-assisted medial unicondylar knee arthroplasty between June 2023 and July 2024 was retrospectively analyzed, including 47 knees on left side and 63 knees on right side. There were 37 males (40 knees) and 63 females (70 knees) with a mean age of 65.4 years (range, 59-71 years). Body mass index was 22.2-28.6 kg/m2 (mean, 25.4 kg/m2). The disease duration ranged from 1 to 8 years (mean, 3.4 years). Preoperative planning was performed by Naton robotic surgical system based on lower limb CT data. The final prosthesis size after osteotomy was recorded and compared with the preoperative plan to analyse whether it was consistent with the preoperative plan, as well as the situation of knee flexion and extension gaps (<0.5 mm, >2.0 mm) corresponding to the different models of prostheses. ResultsDuring operation, 5 patients (5 knees) were treated with traditional UKA due to mechanical arm failure, software obstacles, significant bone amputation bias, or loose reference frame, and were excluded from the final analysis. The remaining 95 patients (105 knees) successfully received Naton robot-assisted surgery, and no related complications occurred. The prosthesis size was consistent with the preoperative plan in 101 knees (96.2%) on the femur side, 100 knees (95.2%) on the tibia side, and 97 knees (92.4%) on both femur and tibia sides. The prosthesis size was inconsistent in 3 cases (2.86%) on the femur side alone, 4 cases (3.81%) on the tibial side alone, and 1 case (0.95%) on both femur and tibial sides. Among the prostheses with different models, the flexion and extension gaps were less than 0.5 mm in 3 knees, the flexion gap was less than 0.5 mm and the extension gap was more than 2.0 mm in 3 knees, and the flexion gap was more than 2.0 mm and the extension gap was less than 0.5 mm in 2 knees. Conclusion The accuracy of prosthesis size selection for Naton robot-assisted medial unicondylar knee arthroplasty is relatively high.