Numerical simulation is one of the most significant methods to predict the temperature distribution in high-intensity focused ultrasound (HIFU) therapy. In this study, the adopted numerical simulation was used based on a transcranial ultrasound therapy model taking a human skull as a reference. The approximation of the Westervelt formula and the Pennes bio-heat conduction equation were applied to the simulation of the transcranial temperature distribution. According to the temperature distribution and the Time Reversal theory, the position of the treatable focal region was corrected and the hot spot existing in the skull was eliminated. Furthermore, the influence of the exposure time, input power and the distance between transducer and skull on the temperature distribution was analyzed. The results showed that the position of the focal region could be corrected and the hot spot was eliminated using the Time Reversal theory without affecting the focus. The focal region above 60℃ could be formed at the superficial tissue located from the skull of 20 mm using the hot spot elimination method and the volume of the focal region increases with the exposure time and the input power in a nonlinear form. When the same volume of the focal region was obtained, the more power was inputted, the less the exposure time was needed. Moreover, the volume of the focal region was influenced by the distance between the transducer and the skull.
The temperature during the brain tumor therapy using high-intensity focused ultrasound (HIFU) should be controlled strictly. This research aimed at realizing uniform temperature distribution in the focal region by adjusting driving signals of phased array transducer. The three-dimensional simulation model imitating craniotomy HIFU brain tumor treatment was established based on an 82-element transducer and the computed tomography (CT) data of a volunteer's head was used to calculate and modulate the temperature distributions using the finite difference in time domain (FDTD) method. Two signals which focus at two preset targets with a certain distance were superimposed to emit each transducer element. Then the temperature distribution was modulated by changing the triggering time delay and amplitudes of the two signals. The results showed that when the distance between the two targets was within a certain range, a focal region with uniform temperature distribution could be created. And also the volume of focal region formed by one irradiation could be adjusted. The simulation results would provide theoretical method and reference for HIFU applying in clinical brain tumor treatment safely and effectively.
The effect of relaxation time in hyperbolic heat transfer model on the temperature field of microwave ablation of atrial fibrillation was investigated. And the results were compared with those calculated by Pennes model. A three-dimensional model of microwave ablation of atrial fibrillation was constructed. The relaxation time (τ) was 0, 1, 5, 8, 10, 15 and 20 s, respectively. And the temperature field of myocardial tissue was obtained. The results showed that the highest temperature of the hyperbolic model was 21.8 ℃ lower than that of the Pennes model at the beginning of ablation. With the increase of ablation time, the highest temperature tended to be the same. The lesion dimensions appeared at 3, 4, 6, 7, 8, 9, and 10 s, respectively after ablation. Therefore, the influence of hyperbolic model on temperature will decrease with the increase of the ablation time. At the beginning of ablation, the relaxation time will hinder the speed of myocardial thermal diffusion. The larger the relaxation time is, the slower the speed of thermal diffusion is. This study provides a reference for the application of hyperbolic model in microwave ablation of atrial fibrillation.