west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "杨必" 6 results
  • 角膜塑形镜配戴后眼总和散光发生改变一例

    Release date:2021-06-23 07:35 Export PDF Favorites Scan
  • Visual Performance in Moderate to Severe Astigmatism : Rigid Gas-permeable Contact Lenses versus Spectacles

    目的 比较中高度散光患者配戴框架眼镜和透气性硬性接触镜(RGPCL)的主客观视觉质量。 方法 选取2008年6月-2011年5月中高度角膜散光20例共40只眼进行角膜地形图、综合验光仪验光等检查后,选择合适试戴片作配适评估并定制RGPCL。要求患者戴镜后1周、1个月、3个月和6个月复查,记录矫正视力、镜片配适、眼部情况,并在第4次复查时进行对比敏感度视力检查及主观问卷调查。 结果 RGPCL矫正视力优于框架眼镜,但两者对比敏感度视力在各空间频率均无明显差异。主观评分时,远视力两者无明显差别;中距离视力框架眼镜评分(3.825 ± 0.245)分,RGPCL评分(3.525 ± 0.302)分,差异有统计学意义(t=5.339,P=0.000);近距离视力框架眼镜评分(3.795 ± 0.233)分,RGPCL评分(3.690 ± 0.194)分,差异有统计学意义(t=3.462,P=0.030)。有45%患者选择RGPCL为主要配戴方式;40%患者选择RGP CL和框架眼镜交替使用的方式;10%患者选择仅在有特殊社交需求时使用RGPCL;另5%患者放弃使用RGPCL。 结论 RGPCL和框架眼镜矫正中高度角膜散光均能取得较满意效果,在中近距离精细作业时框架眼镜矫正视力更为稳定清晰。但由于RGPCL在成像质量和外观上的优势,多数患者仍愿意坚持配戴RGPCL。

    Release date:2016-09-08 09:14 Export PDF Favorites Scan
  • Human Resource and Development Proposal of Optometry in China

    Optometry has become the second class course under the allied health professions since 2012, and has been the National undergraduate enrollment directory. According to the definition of optometry provided by the World Council of Optometry, the jobs of optometrist in China include the basic eye care, basic optometry, contact lens fitting, binocular vision anomaly treatment, strabismus and amblyopia treatment, low vision treatment, special ocular examination, maintenance of equipment related to optometry, operation and sales management. At present, the demand of professional optometrist is great. However, the development of optometrical education is limited by the lack of professional ranks. The professional ranks and titles for optometrist, corresponding registration and examination system should be established by the Ministry of Health as soon as possible, in order for the development of optometrical education and human resource management.

    Release date: Export PDF Favorites Scan
  • Comparison of the changes of corneal astigmatism after long-term spherical and toric orthokeratology wearing

    ObjectiveTo compare the changes of corneal astigmatism after long-term spherical and toric orthokeratology wearing, and to investigate the effects of different orthokeratology design on corneal astigmatism.MethodsThe medical records of myopic adolescent patients who have been prescribed spherical and toric orthokeratology in the contact lens clinic of West China Hospital, Sichuan University between January 2019 and December 2021 were analyzed retrospectively.The differences of corneal astigmatism changes after wearing spherical and toric orthokeratology for a long time and one month discontinuation were compared. The influencing factors of corneal astigmatism changes were analyzed. ResultsA total of 156 patients were included. There were 76 cases (76 eyes) in spherical orthokeratology group and 80 cases (80 eyes) in toric orthokeratology group. There was no significant difference between the two groups in age, gender, baseline myopia diopter and total lens wearing time (P>0.05). There were statistically significant differences between the spherical orthokeratology group and the toric orthokeratology group in the baseline corneal flat K value [42.1 (41.3, 43.3) vs. 43.1 (42.0, 44.1) D], baseline corneal steep K value [(43.4±1.3) vs. (44.6±1.5) D], baseline corneal astigmatism [(1.1±0.5) vs. (1.6±0.6) D], and baseline total eye astigmatism [−0.6 (−1.2, 0.0) vs. −1.4 (−1.8, −1.0) D] before wearing the orthokeratology (P<0.05). Compared with the baseline value, 1 month after the two groups stopped wearing the orthokeratology, the corneal flat K values became flatter [spherical orthokeratology group: 42.09 (41.28, 43.34) vs. 41.73 (40.98, 43.16) D, toric orthokeratology group: 43.09 (41.95, 44.10) vs. 42.61 (41.52, 43.56) D; P<0.05], the changes of corneal steep K values were not statistically significant (P>0.05), but the corneal astigmatism values increased [spherical orthokeratology group: (1.05±0.49) vs. (1.37±0.56) D, toric orthokeratology group: (1.62±0.57) vs. (1.99±0.63) D; P<0.05]. There was no significant difference in the changes of corneal flat K value, corneal steep K value and corneal astigmatism between the two groups (P>0.05). Multivariate analysis showed that age (P=0.011) and the total duration of orthokeratology wearing (P=0.004) were the main factors affecting the changes of corneal astigmatism. ConclusionAfter 1 month of non-wearing, the flat K value of the cornea becomes flat, the steep K value remains unchanged, and the corneal astigmatism increases. There is no difference in the effect of the spherical and toric orthokeratology on corneal astigmatism. The change of corneal astigmatism is related to the patient’s age and the total duration of wearing the orthokeratology. The younger the age, the longer the duration of orthokeratology wearing, the more significant the increase of corneal astigmatism after stopping wearing the orthokeratology.

    Release date: Export PDF Favorites Scan
  • Research on Residual Aberrations Correction with Adaptive Optics Technique in Patients Undergoing Orthokeratology

    We conducted this study to explore the influence of the ocular residual aberrations changes on contrast sensitivity (CS) function in eyes undergoing orthokeratology using adaptive optics technique. Nineteen subjects' nineteen eyes were included in this study. The subjects were between 12 and 20 years (14.27±2.23 years) of age. An adaptive optics (AO) system was adopted to measure and compensate the residual aberrations through a 4-mm artificial pupil, and at the same time the contrast sensitivities were measured at five spatial frequencies (2,4,8,16, and 32 cycles per degree).The CS measurements with and without AO correction were completed. The sequence of the measurements with and without AO correction was randomly arranged without informing the observers. A two-interval forced-choice procedure was used for the CS measurements. The paired t-test was used to compare the contrast sensitivity with and without AO correction at each spatial frequency. The results revealed that the AO system decreased the mean total root mean square (RMS) from 0.356 μm to 0.160 μm(t=10.517, P<0.001), and the mean total higher-order RMS from 0.246 μm to 0.095 μm(t=10.113, P<0.001). The difference in log contrast sensitivity with and without AO correction was significant only at 8 cpd (t=-2.51, P=0.02). Thereby we concluded that correcting the ocular residual aberrations using adaptive optics technique could improve the contrast sensitivity function at intermediate spatial frequency in patients undergoing orthokeratology.

    Release date:2017-01-17 06:17 Export PDF Favorites Scan
  • Application of virtual reality technology in low vision teaching

    Objective To explore the application effect of virtual reality (VR) technology in low vision teaching for optometry students. Methods Undergraduate students majoring in optometry at West China School of Medicine of Sichuan University were selected as the research subjects. The students enrolled in 2020 adopted the traditional lecture-based learning (LBL) teaching mode (LBL teaching group), while the students enrolled in 2021 adopted the VR teaching mode (VR teaching group). Both groups of students had studied the content of the same chapter on low vision, completed in class tests after learning, and completed a questionnaire survey. Results There were 28 students in the VR teaching group and 30 students in the LBL teaching group. There was no statistically significant difference in age and gender composition between the two groups of students (P>0.05). The in-class test scores of students in the VR teaching group were higher than those in the LBL teaching group [86.43±6.10 vs. 78.10±7.69, P<0.05)]. Except for “subjective discomfort with this teaching mode”, the differences in other evaluation results between the two groups were statistically significant (P<0.05). VR teaching group students generally believed that applying VR technology to low vision teaching helped understand the visual experience and daily life status of low vision patients, improved learning efficiency and hands-on ability, reduced learning burden, and hoped to use this teaching mode routinely in other subject teaching. All students in the VR teaching group believed that this teaching mode was interesting, highly innovative, and enhanced teacher-student interaction.Conclusions Applying VR technology to low vision teaching can enable students to personally experience the impact of various diseases on patients’ visual function and daily life. This teaching method not only optimizes and improves teaching effectiveness, but also has a high acceptance rate among students, which is worth further promoting in future optometry teaching.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content