To evaluate the cl inical results of less invasive stabil ization system (LISS) for femur supercondylar and intercondylar fractures. Methods From March 2004 to November 2005, 47 patients with 49 intercondylar and supercondylar fractures were treated. Of all the patients, there were 34 males and 13 females with an average of 39.7 years (range 19-56 years). The locations were left side in 21 cases and right side in 28 cases. Fracture was caused by traffic accident in 31 cases, fall ing in 8 cases, violence in 6 cases and others in 2 cases. Forty-nine fractures included 14 intercondylar fractures, 21supercondylar fractures and 14 intercondylar and supercondylar fractures; 32 closed fractures and 17 open fractures. According to the AO typing, there were 6 type 33-A1, 8 type 33-A2 , 10 type 33-A3, 7 type 33-C1, 3 type 33-C2 and 15 type 33-C3. The disease course was 30 minutes to 6 days. Articular surface reduction was first performed, then the LISS plate was inserted via two incisions and locking screws were used later. Results The average operation time was 126 minutes (range 48-248 minutes). The blood loss was 180 mL(range 60-1 200 mL). The average follow-up time was 18.6 months (range 12-23 months). There were 4 patients with AP angular deformity and 5 patients with lateral angular deformity (range 2-5°). External rotation deformity was presented in 2 patients. There were no plate breakage, screw loosen and fixation failure. Average bone union time was 5.6 months (range 3-8 months) without infection case. Six cases were treated with il iac bone transplantation for delayed union. Conclusion LISS is one kind of effective treatment to femoral intercondylar and supercondylar fractures.
【Abstract】 Objective To explore the biomechanical properties of a new intramedullary controlled dynamicnail ing (ICDN). Methods Ten pairs of specimens of adult femurs, with the age of 18 to 55 years, were divided into twogroups (groups A1 and B2, n=10). The length of the specimens was (438 ± 10) mm , and the external diameter was (26.4 ± 1.5) mm. The specimens of the two groups were osteotomized transversely after the biomechanical test. ICDNs and GK nails were randomly implanted into the femurs, respectively (groups A2 and B2). Torsional, bending and axial compressive tests were made in each group, and the effect of dynamic compression between the fracture fragments was tested. Results The resistance to compression of groups A1, B1, A2 and B2 were (0.19 ± 0.18) × 106, (0.22 ± 0.12) × 106, (1.67 ± 0.68) × 106 and (0.86 ± 0.32) × 106 N/mm, respectively. There was statistically significant difference between groups A2 and B2 (P lt; 0.01). The bending stiffnesses of coronal section of groups A1, B1, A2 and B2 were (0.94 ± 0.25) × 103, (1.10 ± 0.21) × 103, (0.70 ± 0.22) × 103, (0.64 ± 0.21) × 103 N/mm, respectively. The bending stiffness of sagittal plane of groups A1, B1, A2 and B2 were (1.06 ± 0.26) × 103, (0.96 ± 0.25) × 103, (0.67 ± 0.25) × 103, (0.61 ± 0.18) × 103 N/mm, respectively. There were no statistically significant differences between groups A1 and B1 or between groups A2 and B2 (P gt; 0.05). When the torque was 5 Nm, the torsional stiffness of groups A1, B1, A2 and B2 were (4.00 ± 2.54), (4.76 ± 1.93), (0.50 ± 0.63), (0.35 ± 0.31) Nm/°, respectively. When the torque was8 Nm, the torsional stiffness of groups A1, B1, A2 and B2 were (4.30 ± 3.27), (3.94 ± 2.01), (0.42 ± 0.52), (0.36 ± 0.18) Nm/°, respectively. There were statistically significant differences between groups A1 and A2 or between groups B1 and B2 (P lt; 0.05), and no statistically significant difference between between groups A2 and B2 (P gt; 0.05). The average maximal pressure generated between the fracture fragments which were fixed with ICDN was 21.6 N, and the pressure between the fracture fragments which were fixed with GK nail ing could not be tested. Conclusion The design of ICDN conforms to the special anatomical structure of the femur. ICDN could provide a completely different structure, a different fixation principal and a more balancedfixation than GK nail. ICDN incorporates the flexible and rigid fixation, which is l ikely to be the trend of the fracture fixation.
Objective To evaluate the results of the treatmenton femoral fractures with inverse limited marrow cavity rasping intramedullary interlocking nail . Methods From Jun. 1999 to Sep. 2003, 74 patients with femoralfractures were treated by intramedullary interlocking nail (inverse limited marrow cavity rasping) .There were 62 males and 12 females. Among them, 5 caseswere type 32A1, 7 cases were type 32A2, 12 cases were type 32A3, 35 cases were type 32B2, and 15 cases were type 32C2. Results Seventyfour patients were followed up for 13 to 29 months(15.4 months in average). Thetime for fracture union ranged from 3 to 5 months(3.8 months in average). The overall rate of excellence was 98.7% by Wuyuesong grading. There was 1 case of non-union, 1 case of delayed infection, and 2 cases of bent screw. Conclusion The treatment on femoral fractures with inverse limited marrow cavity rasping intramedullary interlocking nail is easy to operate and has minimum impairment to local circulation. It also promotes the healing and early function.
ObjectiveTo design an auto-compressive and anti-circumrotate intramedullary nail( ACACIN) and to evaluate the preliminary clinical efficacy on fixing adult femur fracture. Methods From January 1998 to June 2001, 23 patientswith femur fracture were stabilized with auto-compressive and anti-circumrotateintramedullary nail. 2-4 elastic blocks were installed into the proximal and distal different distance of quincunx nail to defend circumrotate and axis compress. Results Fracture healing were obtained in all 23 patients treated with auto-compresseiveand anti-circumrotate intramedullary nail, the time of fracture healing was 6-13 weeks in 21 cases and 15-22 weeks in 2 cases of old fracture. There was no complication related to infection, nail break, abnormal union and joint ankylosis. The results were excellent in 19 cases, good in 3 cases, and moderate in 1 case according Kolmert’s criterion for function ; the effective rate was 95.7%. Conclusion Auto-compressive and anti-circumrotate intramedullary nail has a suitable radian for adult femur, can afford stable fixation, anti-circumrotate andaxis compress.