find Keyword "Microscopy, confocal" 13 results
  • Expression of Nogo receptor in rats′ retina during the postnatal development

    Objective To observe the expression of Nogo66 receptor (NgR)in ratsprime; retina during the postnatal development. Methods The expression of NgR in 48 rats were observed by immunofluorescence histochemistry and laserconfocal microscopy 0, 3, 7, 14, 21, 35, 49, 63 days after birth, with 6 rats in each group, respectively. Results The expression of NgR is positive in the retina in the whole duration of growth, and the fluorescence pigmentation was located around the ganglion cell nuclaear. Conclusion The positive expression of NgR suggests that the interaction of NgR and CNS myelin inhibitors not only inhibit neuronal plasticity but also promote it, which could regulate neuronal plasticity.

    Release date:2016-09-02 05:48 Export PDF Favorites Scan
  • Macular light sensibility in idiopathic epiretinal membrane measured by scanning laser ophthalmoscope

    Objective To observe the effect of scanning laser ophthalmoscope (SLO) measuring macular light sensibility on evaluating the visual function in idiopathic epiretinal membrane (IERM), and analyze the relationship among the macular light sensibility, central visual acuity, and the thickness of fovea. Methods Procedure of microperimetry of SLO was performed on 44 patients (55 eyes) with IERM diagnosed by indirect and direct ophthalmoscope and optical coherence tomography (OCT). The light sensibility at 10deg;macular central area was measured. The results were compared with 31 healthy control eyes which underwent the same examinations simutaneously. The correlation among the macular light sensibility, the thickness of fovea measured by OCT, and the results of logarithm visual acuity was anaylzed. Results Compared with the control eyes, macular light sensibility decreased in IERM eyes significantly (F=47.265, Plt;0.01), which had the positive correlation with the decrease of visual acuity (r=0.687, P=0.000) and negative correlation with the retinal thickness of macular fovea (r=-0.532,P=0.003). The mean macular light sensitivity in patients with metamorphopsia decreased obviously compared with which in patients without (t=7.039, P=0.000). The mean macular light sensitivity in patients with prolifertive IERM decreased compared with which in patients with dropsical IERM without statistical difference (t=-1.706, P=0.094). Conclusion Microperimetry of SLO may sensitively reflect the macular visual function of eyes with IERM and quantificationally evaluate the changes of macular light sensibility. The changes of macular light sensitivity correlates with the central visual acuity and retinal thickness of macular fovea. (Chin J Ocul Fundus Dis, 2006, 22: 100-102)

    Release date:2016-09-02 05:51 Export PDF Favorites Scan
  • Reproducibility of Heidelberg retinal tomograph measuring the macular retinal thickness

    ObjectivesTo evaluate the reproducibility of Heidelberg retina tomograph (HRT) macular edema module(MEM) measuring the macular retinal thickness.MethodsSixty-two healthy volunteers (9-68 years old) were examined by HRT-II procedure. The retinal signal width (SW) at macula and fovea and macular edema index (E) were recorded for t-test, Pearson linear-correlation analysis. Intra-subject variation repeatedly measured was analyzed with coefficient of variation, 95% tolerance limits of change (TC), and intraclass coefficient of correlation (ICC). ResultsIn healthy individuals, retinal SW was (0.734±0.236) mm at macula,and (0.781±0.243) mm at fovea; macular E was (1.169±0.619). The coefficient of variation repeatedly measured: retinal SW was (8.7±68)%,retinal SW at the fovea was (8.5±6.7)%, and the average was (15.6±13.9)%; 95%TC of intra-subject sequential repeated measurement was 0.131 (8.9%) of retinal SW, 0.137 (10.5%)of fovea SW,and 0.198 (7.4%) of average E. ICC of one individual repeatedly measured by one operator was 0.950 of macular SW, 0.949 of fovea SW, and 0.898 of average edema index.ConclusionsHRT-II MEM is noninvasive, fast and highly reproducible, which provides a new technique to monitor the objective quantification of macular diseases related to retinal thickness. ( Chin J Ocul Fundus Dis, 2005,21:103-105)

    Release date:2016-09-02 05:52 Export PDF Favorites Scan
  • The anatomical investigation of foveal avascular area

    Objective To observe the dimensions of the capillary blood vessel arch in central fovea of macula and the foveal avascular area (FAZ), and their relationships with age.Methods Retina in macula of 32 cadavers eyes were isolated . Retinal vessels were immunostained by collagen type IV and examined by confocal laser scanning microscopy. The area and diameter of the FAZ were measured, and the relationship between FAZ and age was analysed. Results The parafoveolar capillary network was observed clearly by confocal laser scanning microscopy. The average area of the FAZ was (0.24±0.13) mm2, and the average diameter was (0.54±0.15) mm. The area and diameter of the FAZ did not show any correlation with age.Conclusions The parafoveolar capillary network could be observed by confocal laser scanning microscopy. The size of the FAZ does not change with age. The dimensions of the parafoveolar capillary network may not be influenced by age. (Chin J Ocul Fundus Dis,2003,19:73-75)

    Release date:2016-09-02 06:00 Export PDF Favorites Scan
  • The application of confocal scanning laser tomography in age-related macular degeneration

    Objective To verify the applicable significance of confocal scanning laser retinal tomography in agerelated macular degeneration (AMD). Methods Heidelberg confocal scanning laser tomography was used to measure 75 eyes of 59 patients with AMD, including 25 eyes of 20 patients with exudative AMD, 25 eyes of 16 patients with atrophic AMD, and 25 eyes of 23 patients with macular drusen. The differences of the width, volume and maximum height of Z profile signal of macula were analyzed. Results Z profile signal width in macular tomography of exudative AMD was wider than that of macular drusen; maximum height and volume in macular tomography of exudative AMD were larger than that of macular drusen (P<0.01); Z profile signal width, maximum height,and volume in macular tomography of atrophic AMD were wider and larger than that of macular drusen (P<0.05). Macular volume of exudative AMD was obviously larger than that of atrophic AMD (P<0.01). Conclusion Confocal scanning laser tomography may be one of the useful methods for objective evaluation of morphologic change for the development of AMD. (Chin J Ocul Fundus Dis, 2002, 18: 262-265)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • Corneal nerve fiber damage in different stage of diabetic retinopathy patients with type 2 diabetes

    Objective To observe the corneal nerve fibres damage in different stage of diabetic retinopathy (DR) with type 2 diabetes. Methods A cross-sectional study. One hundred and twenty eyes of 120 patients with type 2 diabetes served as diabetes group. According to International Clinical Diabetic Retinopathy Disease Severity Scales (2002), diabetes patients were classified into 4 subgroups: patients without diabetic retinopathy (NDR), patients with mild or moderate non-proliferative diabetic retinopathy (mNPDR), patients with severe non-proliferative diabetic retinopathy (sNPDR) and patients with proliferative diabetic retinopathy (PDR), each subgroup has 30 eyes of 30 patients. Another 30 eyes of 30 healthy participants served as control group. All eyes were scanned with HRT3 in vivo corneal confocal microscopy. Images of sub-basal nerve plexus were quantified including nerve fiber length (NFL), nerve fiber density (NFD), nerve fiber branch density (NFB), and nerve tortuosity (NT). The correlations of corneal nerve fiber with age, duration of diabetes and glycated hemoglobin (HbA1c) were analyzed using Spearman correlation analysis. Results NFL, NFD and NFB were found to be significantly lower in diabetic patients (F=147.315, 142.586, 65.898;P=0.000, 0.000, 0.000), NT was significantly greater in diabetic patients (F=39.431,P=0.000), when compared to control group. In diabetic patients, NFL, NFD and NFB were gradually reduced with DR severity, NT was gradually increased with DR severity. While the difference of NFL, NFD, NFB, NT was not statistically significant between sNPDR and PDR subgroups (P>0.05), but was statistically significant between other subgroups (P<0.05). Spearman correlation analysis results showed that age (r=-0.071, -0.080, 0.001, 0.100;P=0.391, 0.328, 0.991, 0.224) and HbA1c (r=-0.109, -0.115, -0.126, 0.025;P=0.238, 0.211, 0.169, 0.781) had no correlation with NFL, NFD, NFB, NT. Duration of diabetes was negatively correlated with the NFL, NFD (r=-0.212, -0.264;P= 0.020, 0.004), positive correlated with NT (r=0.261,P=0.004), and had no correlation with NFB (r=-0.119,P=0.194). Conclusions Corneal nerve fiber loss and nerve tortuosity increased were found in patients with type 2 diabetes, and even without diabetic retinopathy. The progress of corneal neuropathy was correlated with the severity of DR, but it was not change significantly between sNPDR and PDR.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • Comparison of confocal laser scanning colorful fundus imaging and color fundus photography for detection of diabetic retinopathy

    ObjectiveTo compare the imaging characteristics and detection of various types of lesions in diabetic retinopathy (DR) with colorful laser scanning fundus imaging (MSLI) and traditional color fundus photography (CFP).MethodsProspective case series observational study. A total of 38 eyes of 38 patients with DR diagnosed by clinical examination were included in the study. Among them, 21 were male and 17 were female; the mean age was 62.6±11.2 years; the average duration of diabetes was 14.3±7.5 years. All the patients were performed CFP, MSLI, frequency domain optical coherence tomography (SD-OCT), fluorescein angiography (FFA) examination. Using the Helielberg Spectralis HRA+OCT MSLI inspection, one scan simultaneously obtained 488 nm blue reflection (BR), 515 nm green light reflection (GR), 820 nm infrared light reflection (IR), and multicolor image (MC). The detection of traditional CFP and MC on microaneurysm (MA), hard exudation (HEX), cotton plaque (CWS), intraretinal hemorrhage (IRH), intraretinal microvascular abnormality (IRMA), venous bead (VB), venous ring (VL), macular edema (DME), macular anterior membrane (MEM) and laser photocoagulation (LB) were comparatively observed. The results of FFA examination were used as the diagnostic criteria for lesions. SD-OCT was used to determine the location and depth of lesions and the diagnostic reference for DME and MEM.ResultsThe numbers of eyes with MA (χ2=10.460), DME (χ2=4.006), MEM (χ2=4.444) was significantly higher in MC than that of traditional CFP. But the number of eyes with IRH (χ2=0.103), CWS (χ2=1.515), HEX (χ2=0.227), IRMA (χ2=0.051), VB (χ2=0.001), VL (χ2=0.149), VH (χ2=0.693) and LB (χ2=0.720) were not statistically significant between two methods (P>0.05). The imaging quality of MSLI mode is obviously better than that of traditional CFP. Among them, GR imaging shows the best structural changes of superficial retina in MA, CWS, HEX, MEM, etc. IR imaging shows clear depth in deep retina such as LB. DME was green on MC and the weak low-reflection dark area was visible on the IR image, which were consistent with the DME range indicated by the SD-OCT examination.ConclusionsCompared with the traditional CFP, the MSLI can clearly show the DR lesion. The number of checkouts is high on MA, DME and MEM by MC image.

    Release date:2018-07-23 04:02 Export PDF Favorites Scan
  • Application of new fundus imaging in diabetic retinopathy

    Diabetic retinopathy (DR) is one of the most common causes of visual impairment and blindness in diabetic patients. It is particularly important to set up simpler, safer, non-invasive and highly effective methods for diagnosis as well as monitoring DR. A variety of new fundus imaging techniques show great advantages in early diagnosis, treatment and monitoring of DR in recent years. The main characteristics of wide-field scanning laser imaging system is achieving a large range of retinal image in a single photograph and without mydriasis. It provides several options for color images, FFA and FAF, which satisfy to detect the retina, choroid and vascular structure. Multi spectral fundus imaging system is suitable for DR screening, because it is able to recognize the typical characteristics of DR, such as microaneurysms, hemorrhage and exudation, and is non-invasive and convenient. OCT angiography is a quantitative examination that provides foveal avascular zone area, macular blood flow density, which provides strong evidence for DR diagnosis. The improvement of these new techniques will help us to build up a personalized evaluation system of DR.

    Release date:2019-01-19 09:03 Export PDF Favorites Scan
  • The diagnostic value of multicolor scanning laser imaging combined with swept-source optical coherence tomography for lacquer cracks and myopia stretch lines of pathological myopia

    ObjectiveTo analyze the diagnostic value of multicolor scanning laser imaging (confocal scanning laser ophthalmoscopy, cSLO) combined with swept-source optical coherence tomography (SS-OCT) for lacquer cracks (LC) and myopia stretch lines (MSL) of pathological myopia.MethodsA observational study. A total of 83 eyes of 58 patients with pathological myopia were recruited from May 2017 to January 2018 in Department of Ophthalmology of The First People’s Hospital Affiliated to Shanghai Jiao Tong University. Among 58 patients, 20 were males (30 eyes) and 38 were females (53 eyes). The mean age was 50.65±12.02 (range from 24 to 70) years old; the average BCVA was 0.37±0.32; the average diopter was −11.38±4.96 D; and the average axial length was 28.91±2.15 mm. All participants underwent FFA and ICGA examination to obtain FFA, ICGA, infrared light reflection (IR) and autofluorescence (AF) images. SS-OCT was applied for scanning macular and optic disc at 9 mm × 9 mm range. cSLO was performed with macular as the center. All images were inspected carefully by three independent observers and the consistency test was detect. LC were diagnosed as hyperreflective line in FFA and hypofluorescent linear lesions in late ICGA. MSL were defined as both hypofluorescent linear lesions in FFA and late ICGA. The accuracy of each inspection item in the diagnosis of LC was detected. The optimal technique was applied with SS-OCT to further explore the detection rate of LC.ResultsThe intra-observer reproducibility was good to excellent for all measurements (Kappa=0.938, P<0.01). The positive detection rate of LC and MSL was highest in the standard images of cSLO (77.1%), followed by SS-OCT red free (73.1%), fundus photography (72.3%), IR (72.3%) and AF (49.4%). The cSLO was optimal in the test consistency (Kappa=0.520, P<0.01) and accuracy (the area under the receiver operating characteristic was 0.750). SS-OCT and cSLO were jointly applied to diagnosis of LC and MSL in high myopia. The positive detection rate of LC, MSL and LC+MSL were 91.7%, 91.2% and 93.3% respectively. The characteristics of LC in SS-OCT were irregularities and discontinuous of the RPE-Bruch membrane line, discontinuous inner ellipsoid zone, thinner choroid, an increased light penetrance into deeper tissues, and RPE fracture in severe cases. MSL was mainly manifested as RPE clumps, visible large choroidal vessels protruding and pushing the overlying RPE toward the vitreous.ConclusionsThe diagnosis rate of LC in pathological myopia by cSLO is 77.1%. The standard images of cSLO combined with SS-OCT can diagnose LC, MSL and LC+MSL at rates of 91.7%, 91.2% and 93.3% respectively.

    Release date:2019-11-19 09:24 Export PDF Favorites Scan
  • The clinical applications of adaptive optics scanning laser ophthalmoscope

    Adaptive optics (AO) is a technique to improve the performance of optical systems by reducing the influence of optical aberrations. Combined with scanning laser ophthalmoscope (AOSLO), the aberration of human refractive system can be corrected. Thus, the resolution and quality of imaging can be greatly improved to the cellular level in vivo retina (such as photoreceptor, nerve fibers, vascular parietal cell), therefore the earlier changes of the diseases can be detected. At the same time, microstructure changes of retinal can also be observed during the follow-up of the disease. Due to inherent technical defects of AOSLO, its wide application in clinical practice is limited. With the continuous progress of AO technology and the further improvement of related software functions, the function of the system will become more stronger and will play a more and more important role in scientific research and clinic.

    Release date:2020-01-11 10:26 Export PDF Favorites Scan