west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "XIONG Peng" 8 results
  • An echo state network algorithm based on recursive least square for electrocardiogram denoising

    Electrocardiogram (ECG) is easily submerged in noise of the complex environment during remote medical treatment, and this affects the intelligent diagnosis of cardiovascular diseases. Considering this situation, this paper proposes an echo state network (ESN) denoising algorithm based on recursive least square (RLS) for ECG signals. The algorithm trains the ESN through the RLS method, and can automatically learn the deep nonlinear and differentiated characteristics in the noisy ECG data, and then the network can use these characteristic to separate out clear ECG signals automatically. In the experiment, the proposed method is compared with the wavelet transform with subband dependent threshold and the S-transform method by evaluating the signal-to-noise ratio and root mean square error. Experimental results show that the denoising accuracy is better and the low frequency component of the signal is well preserved. This method can effectively filter out complex noise and effectively preserve the effective information of ECG signals, which lays a foundation for the recognition of ECG signal feature waveform and the intelligent diagnosis of cardiovascular disease.

    Release date:2018-08-23 05:06 Export PDF Favorites Scan
  • Automatic removal algorithm of electrooculographic artifacts in non-invasive brain-computer interface based on independent component analysis

    The non-invasive brain-computer interface (BCI) has gradually become a hot spot of current research, and it has been applied in many fields such as mental disorder detection and physiological monitoring. However, the electroencephalography (EEG) signals required by the non-invasive BCI can be easily contaminated by electrooculographic (EOG) artifacts, which seriously affects the analysis of EEG signals. Therefore, this paper proposed an improved independent component analysis method combined with a frequency filter, which automatically recognizes artifact components based on the correlation coefficient and kurtosis dual threshold. In this method, the frequency difference between EOG and EEG was used to remove the EOG information in the artifact component through frequency filter, so as to retain more EEG information. The experimental results on the public datasets and our laboratory data showed that the method in this paper could effectively improve the effect of EOG artifact removal and improve the loss of EEG information, which is helpful for the promotion of non-invasive BCI.

    Release date: Export PDF Favorites Scan
  • Detection of inferior myocardial infarction based on densely connected convolutional neural network

    Inferior myocardial infarction is an acute ischemic heart disease with high mortality, which is easy to induce life-threatening complications such as arrhythmia, heart failure and cardiogenic shock. Therefore, it is of great clinical value to carry out accurate and efficient early diagnosis of inferior myocardial infarction. Electrocardiogram is the most sensitive means for early diagnosis of inferior myocardial infarction. This paper proposes a method for detecting inferior myocardial infarction based on densely connected convolutional neural network. The method uses the original electrocardiogram (ECG) signals of serially connected Ⅱ, Ⅲ and aVF leads as the input of the model and extracts the robust features of the ECG signals by using the scale invariance of the convolutional layers. The characteristic transmission of ECG signals is enhanced by the dense connectivity between different layers, so that the network can automatically learn the effective features with strong robustness and high recognition, so as to achieve accurate detection of inferior myocardial infarction. The Physikalisch Technische Bundesanstalt diagnosis public ECG database was used for verification. The accuracy, sensitivity and specificity of the model reached 99.95%, 100% and 99.90%, respectively. The accuracy, sensitivity and specificity of the model are also over 99% even though the noise exists. Based on the results of this study, it is expected that the method can be introduced in the clinical environment to help doctors quickly diagnose inferior myocardial infarction in the future.

    Release date:2020-04-18 10:01 Export PDF Favorites Scan
  • An automatic pulmonary nodules detection algorithm with multi-scale information fusion

    Lung nodules are the main manifestation of early lung cancer. So accurate detection of lung nodules is of great significance for early diagnosis and treatment of lung cancer. However, the rapid and accurate detection of pulmonary nodules is a challenging task due to the complex background, large detection range of pulmonary computed tomography (CT) images and the different sizes and shapes of pulmonary nodules. Therefore, this paper proposes a multi-scale feature fusion algorithm for the automatic detection of pulmonary nodules to achieve accurate detection of pulmonary nodules. Firstly, a three-layer modular lung nodule detection model was designed on the deep convolutional network (VGG16) for large-scale image recognition. The first-tier module of the network is used to extract the features of pulmonary nodules in CT images and roughly estimate the location of pulmonary nodules. Then the second-tier module of the network is used to fuse multi-scale image features to further enhance the details of pulmonary nodules. The third-tier module of the network was fused to analyze the features of the first-tier and the second-tier module of the network, and the candidate box of pulmonary nodules in multi-scale was obtained. Finally, the candidate box of pulmonary nodules under multi-scale was analyzed with the method of non-maximum suppression, and the final location of pulmonary nodules was obtained. The algorithm is validated by the data of pulmonary nodules on LIDC-IDRI common data set. The average detection accuracy is 90.9%.

    Release date:2020-08-21 07:07 Export PDF Favorites Scan
  • Detection algorithm of paroxysmal atrial fibrillation with sparse coding based on Riemannian manifold

    In order to solve the problem that the early onset of paroxysmal atrial fibrillation is very short and difficult to detect, a detection algorithm based on sparse coding of Riemannian manifolds is proposed. The proposed method takes into account that the nonlinear manifold geometry is closer to the real feature space structure, and the computational covariance matrix is used to characterize the heart rate variability (RR interval variation), so that the data is in the Riemannian manifold space. Sparse coding is applied to the manifold, and each covariance matrix is represented as a sparse linear combination of Riemann dictionary atoms. The sparse reconstruction loss is defined by the affine invariant Riemannian metric, and the Riemann dictionary is learned by iterative method. Compared with the existing methods, this method used shorter heart rate variability signal, the calculation was simple and had no dependence on the parameters, and the better prediction accuracy was obtained. The final classification on MIT-BIH AF database resulted in a sensitivity of 99.34%, a specificity of 95.41% and an accuracy of 97.45%. At the same time, a specificity of 95.18% was realized in MIT-BIH NSR database. The high precision paroxysmal atrial fibrillation detection algorithm proposed in this paper has a potential application prospect in the long-term monitoring of wearable devices.

    Release date:2020-10-20 05:56 Export PDF Favorites Scan
  • Detection of inferior myocardial infarction based on morphological characteristics

    Early accurate detection of inferior myocardial infarction is an important way to reduce the mortality from inferior myocardial infarction. Regrading the existing problems in the detection of inferior myocardial infarction, complex model structures and redundant features, this paper proposed a novel inferior myocardial infarction detection algorithm. Firstly, based on the clinic pathological information, the peak and area features of QRS and ST-T wavebands as well as the slope feature of ST waveband were extracted from electrocardiogram (ECG) signals leads Ⅱ, Ⅲ and aVF. In addition, according to individual features and the dispersion between them, we applied genetic algorithm to make judgement and then input the feature with larger degree into support vector machine (SVM) to realize the accurate detection of inferior myocardial infarction. The proposed method in this paper was verified by Physikalisch-Technische Bundesanstalt (PTB) diagnostic electrocardio signal database and the accuracy rate was up to 98.33%. Conforming to the clinical diagnosis and the characteristics of specific changes in inferior myocardial infarction ECG signal, the proposed method can effectively make precise detection of inferior myocardial infarction by morphological features, and therefore is suitable to be applied in portable devices development for clinical promotion.

    Release date:2021-04-21 04:23 Export PDF Favorites Scan
  • ST segment morphological classification based on support vector machine multi feature fusion

    ST segment morphology is closely related to cardiovascular disease. It is used not only for characterizing different diseases, but also for predicting the severity of the disease. However, the short duration, low energy, variable morphology and interference from various noises make ST segment morphology classification a difficult task. In this paper, we address the problems of single feature extraction and low classification accuracy of ST segment morphology classification, and use the gradient of ST surface to improve the accuracy of ST segment morphology multi-classification. In this paper, we identify five ST segment morphologies: normal, upward-sloping elevation, arch-back elevation, horizontal depression, and arch-back depression. Firstly, we select an ST segment candidate segment according to the QRS wave group location and medical statistical law. Secondly, we extract ST segment area, mean value, difference with reference baseline, slope, and mean squared error features. In addition, the ST segment is converted into a surface, the gradient features of the ST surface are extracted, and the morphological features are formed into a feature vector. Finally, the support vector machine is used to classify the ST segment, and then the ST segment morphology is multi-classified. The MIT-Beth Israel Hospital Database (MITDB) and the European ST-T database (EDB) were used as data sources to validate the algorithm in this paper, and the results showed that the algorithm in this paper achieved an average recognition rate of 97.79% and 95.60%, respectively, in the process of ST segment recognition. Based on the results of this paper, it is expected that this method can be introduced in the clinical setting in the future to provide morphological guidance for the diagnosis of cardiovascular diseases in the clinic and improve the diagnostic efficiency.

    Release date: Export PDF Favorites Scan
  • Detection model of atrial fibrillation based on multi-branch and multi-scale convolutional networks

    Atrial fibrillation (AF) is a life-threatening heart condition, and its early detection and treatment have garnered significant attention from physicians in recent years. Traditional methods of detecting AF heavily rely on doctor’s diagnosis based on electrocardiograms (ECGs), but prolonged analysis of ECG signals is very time-consuming. This paper designs an AF detection model based on the Inception module, constructing multi-branch detection channels to process raw ECG signals, gradient signals, and frequency signals during AF. The model efficiently extracted QRS complex and RR interval features using gradient signals, extracted P-wave and f-wave features using frequency signals, and used raw signals to supplement missing information. The multi-scale convolutional kernels in the Inception module provided various receptive fields and performed comprehensive analysis of the multi-branch results, enabling early AF detection. Compared to current machine learning algorithms that use only RR interval and heart rate variability features, the proposed algorithm additionally employed frequency features, making fuller use of the information within the signals. For deep learning methods using raw and frequency signals, this paper introduced an enhanced method for the QRS complex, allowing the network to extract features more effectively. By using a multi-branch input mode, the model comprehensively considered irregular RR intervals and P-wave and f-wave features in AF. Testing on the MIT-BIH AF database showed that the inter-patient detection accuracy was 96.89%, sensitivity was 97.72%, and specificity was 95.88%. The proposed model demonstrates excellent performance and can achieve automatic AF detection.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content